Zhenchao Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhenchao Tang has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- Jie Tian
Beihang University
4 shared publications Wancheng Liu
School of Engineering Medicine and School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China
3 shared publicationsYang Liu
School of Engineering Medicine and School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China
3 shared publicationsBowen Zhang
Department of Anesthesiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Chaoyang District, Beijing, China
2 shared publicationsJie Yu
Department of Anesthesiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Chaoyang District, Beijing, China
2 shared publications- Jingying Jiang
School of Engineering Medicine, Beihang University, Beijing, China
2 shared publications
Latest Publications
- 16 November 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
Fully Automated Segmentation of Chronic Total Occlusion Lesions on Coronary CT Angiography Using Deep Learning
Reliable quantitative assessment for chronic total occlusion (CTO) lesions depends on accurate segmentation of coronary computed tomography angiography (CCTA) images. However, incomplete contrast opacification and complex lesion morphology make precise delineation particularly challenging. We developed an Atrous Attention U-Net (AAU-Net) for CTO segmentation and integrated it into a fully automated workflow comprising heart localization, CTO localization, and lesion segmentation. This retrospective study included 565 CTO lesions from 551 patients who underwent prospectively ECG-gated CCTA at three centers. Standalone segmentation used reference-mask-derived lesion-containing slices and regions of interest, whereas the automated workflow used predicted localization without reference-mask information or manual correction. Under reference-defined localization, AAU-Net achieved a Dice score of 0.8421 and intersection over union of 0.7312 in the internal test set, although performance varied by anatomical location and center. Performance decreased in the fully automated workflow, with Dice scores of 0.6922 in the internal test set, 0.5822 in external test set 1, and 0.6480 in external test set 2, potentially reflecting localization errors and differences between the separately trained segmentation models. In an exploratory locked-model radiomics analysis, features derived from automated segmentations showed numerically lower predictive performance than those derived from manual segmentations. Overall, AAU-Net showed favorable segmentation performance under reference-defined localization, but the fully automated workflow demonstrated lower performance that varied across centers. The radiomics findings demonstrate technical feasibility rather than established clinical utility. Further optimization and larger prospective multicenter validation are required before clinical deployment.
- 16 November 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
Fully Automated Segmentation of Chronic Total Occlusion Lesions on Coronary CT Angiography Using Deep Learning
Reliable quantitative assessment for chronic total occlusion (CTO) lesions depends on accurate segmentation of coronary computed tomography angiography (CCTA) images. However, incomplete contrast opacification and complex lesion morphology make precise delineation particularly challenging. We developed an Atrous Attention U-Net (AAU-Net) for CTO segmentation and integrated it into a fully automated workflow comprising heart localization, CTO localization, and lesion segmentation. This retrospective study included 565 CTO lesions from 551 patients who underwent prospectively ECG-gated CCTA at three centers. Standalone segmentation used reference-mask-derived lesion-containing slices and regions of interest, whereas the automated workflow used predicted localization without reference-mask information or manual correction. Under reference-defined localization, AAU-Net achieved a Dice score of 0.8421 and intersection over union of 0.7312 in the internal test set, although performance varied by anatomical location and center. Performance decreased in the fully automated workflow, with Dice scores of 0.6922 in the internal test set, 0.5822 in external test set 1, and 0.6480 in external test set 2, potentially reflecting localization errors and differences between the separately trained segmentation models. In an exploratory locked-model radiomics analysis, features derived from automated segmentations showed numerically lower predictive performance than those derived from manual segmentations. Overall, AAU-Net showed favorable segmentation performance under reference-defined localization, but the fully automated workflow demonstrated lower performance that varied across centers. The radiomics findings demonstrate technical feasibility rather than established clinical utility. Further optimization and larger prospective multicenter validation are required before clinical deployment.
- 19 September 2026
- Published by Elsevier in Measurement
- Vol. 292
A multi-angle Cartesian scanning strategy for large field-of-view Magnetic Particle Imaging
- 19 September 2026
- Published by Elsevier in Measurement
- Vol. 292
A multi-angle Cartesian scanning strategy for large field-of-view Magnetic Particle Imaging
- 15 September 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- p. 1-18
U-Net-Based Automated Quality Control of Knee Radiographs: Dual-Center Validation and Clinical Intervention
Knee radiography quality directly affects diagnostic accuracy. Current quality control (QC) mainly involves subjective, inefficient manual assessment, while existing automated tools lack sufficient clinical validation. We developed and validated an interpretable artificial intelligence (AI) framework for the automated QC of knee anteroposterior (AP) and lateral (LAT) radiographs and explored its clinical value. This two-stage retrospective study developed and validated U-Net models using 1600 adult single-knee AP and LAT radiographs from 800 patients at two centers. Anatomical segmentation and landmark localization yielded QC indices. Segmentation was evaluated using the Dice similarity coefficient (DSC); landmark localization using Euclidean error, normalized distance error (NDE), and percentage of correct keypoints (PCK); and QC performance using the intraclass correlation coefficient (ICC), sensitivity, and specificity. Separately, six radiographers received 4 weeks of AI-based feedback on 948 radiographs from 474 patients. The mean DSCs were 0.964 and 0.936 in the internal and external validation cohorts, respectively, and most of the ICCs exceeded 0.90. The mean AP localization errors were 13.52 pixels internally and 19.15 pixels externally, and the corresponding LAT values were 26.34 and 41.50 pixels, respectively. PCK@20% was 100.0%/99.4% for AP and 81.6%/61.8% for LAT in the internal/external cohorts. QC sensitivity ranged from 91.67% to 98.36%, and the specificity ranged from 89.13% to 99.10%. Post-feedback sensitivity showed exploratory numerical gains. Effect sizes ranged from 0.30 to 0.73. The proposed framework enables accurate, objective, and automated QC of knee radiographs, as demonstrated through dual-center validation. The workflow evaluation showed favorable exploratory trends in radiographer sensitivity, warranting further evaluation in prospective controlled studies.
- 15 September 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- p. 1-18
U-Net-Based Automated Quality Control of Knee Radiographs: Dual-Center Validation and Clinical Intervention
Knee radiography quality directly affects diagnostic accuracy. Current quality control (QC) mainly involves subjective, inefficient manual assessment, while existing automated tools lack sufficient clinical validation. We developed and validated an interpretable artificial intelligence (AI) framework for the automated QC of knee anteroposterior (AP) and lateral (LAT) radiographs and explored its clinical value. This two-stage retrospective study developed and validated U-Net models using 1600 adult single-knee AP and LAT radiographs from 800 patients at two centers. Anatomical segmentation and landmark localization yielded QC indices. Segmentation was evaluated using the Dice similarity coefficient (DSC); landmark localization using Euclidean error, normalized distance error (NDE), and percentage of correct keypoints (PCK); and QC performance using the intraclass correlation coefficient (ICC), sensitivity, and specificity. Separately, six radiographers received 4 weeks of AI-based feedback on 948 radiographs from 474 patients. The mean DSCs were 0.964 and 0.936 in the internal and external validation cohorts, respectively, and most of the ICCs exceeded 0.90. The mean AP localization errors were 13.52 pixels internally and 19.15 pixels externally, and the corresponding LAT values were 26.34 and 41.50 pixels, respectively. PCK@20% was 100.0%/99.4% for AP and 81.6%/61.8% for LAT in the internal/external cohorts. QC sensitivity ranged from 91.67% to 98.36%, and the specificity ranged from 89.13% to 99.10%. Post-feedback sensitivity showed exploratory numerical gains. Effect sizes ranged from 0.30 to 0.73. The proposed framework enables accurate, objective, and automated QC of knee radiographs, as demonstrated through dual-center validation. The workflow evaluation showed favorable exploratory trends in radiographer sensitivity, warranting further evaluation in prospective controlled studies.
- Open Access
- 1 October 2025
- Published by Springer Nature in Visual Computing for Industry, Biomedicine, and Art
- Vol. 8 (1)
Application of artificial intelligence in assisting treatment of gynecologic tumors: a systematic review
In recent years, the application of artificial intelligence (AI) in medical image analysis has drawn increasing attention in clinical studies of gynecologic tumors. This study presents the development and prospects of AI applications to assist in the treatment of gynecological oncology. The Web of Science database was screened for articles published until August 2023. “artificial intelligence,” “deep learning,” “machine learning,” “radiomics,” “radiotherapy,” “chemoradiotherapy,” “neoadjuvant therapy,” “immunotherapy,” “gynecological malignancy,” “cervical carcinoma,” “cervical cancer,” “ovarian cancer,” “endometrial cancer,” “vulvar cancer,” “Vaginal cancer” were used as keywords. Research articles related to AI-assisted treatment of gynecological cancers were included. A total of 317 articles were retrieved based on the search strategy, and 133 were selected by applying the inclusion and exclusion criteria, including 114 on cervical cancer, 10 on endometrial cancer, and 9 on ovarian cancer. Among the included studies, 44 (33%) focused on prognosis prediction, 24 (18%) on treatment response prediction, 13 (10%) on adverse event prediction, five (4%) on dose distribution prediction, and 47 (35%) on target volume delineation. Target volume delineation and dose prediction were performed using deep Learning methods. For the prediction of treatment response, prognosis, and adverse events, 57 studies (70%) used conventional radiomics methods, 13 (16%) used deep Learning methods, 8 (10%) used spatial-related unconventional radiomics methods, and 3 (4%) used temporal-related unconventional radiomics methods. In cervical and endometrial cancers, target prediction mostly included treatment response, overall survival, recurrence, toxicity undergoing radiotherapy, lymph node metastasis, and dose distribution. For ovarian cancer, the target prediction included platinum sensitivity and postoperative complications. The majority of the studies were single-center, retrospective, and small-scale; 101 studies (76%) had single-center data, 125 studies (94%) were retrospective, and 127 studies (95%) included Less than 500 cases. The application of AI in assisting treatment in gynecological oncology remains limited. Although the results of AI in predicting the response, prognosis, adverse events, and dose distribution in gynecological oncology are superior, it is evident that there is no validation of substantial data from multiple centers for these tasks.
- 1 October 2025
- Published by Springer Nature in Visual Computing for Industry, Biomedicine, and Art
- Vol. 8 (1)
Open AccessApplication of artificial intelligence in assisting treatment of gynecologic tumors: a systematic review
In recent years, the application of artificial intelligence (AI) in medical image analysis has drawn increasing attention in clinical studies of gynecologic tumors. This study presents the development and prospects of AI applications to assist in the treatment of gynecological oncology. The Web of Science database was screened for articles published until August 2023. “artificial intelligence,” “deep learning,” “machine learning,” “radiomics,” “radiotherapy,” “chemoradiotherapy,” “neoadjuvant therapy,” “immunotherapy,” “gynecological malignancy,” “cervical carcinoma,” “cervical cancer,” “ovarian cancer,” “endometrial cancer,” “vulvar cancer,” “Vaginal cancer” were used as keywords. Research articles related to AI-assisted treatment of gynecological cancers were included. A total of 317 articles were retrieved based on the search strategy, and 133 were selected by applying the inclusion and exclusion criteria, including 114 on cervical cancer, 10 on endometrial cancer, and 9 on ovarian cancer. Among the included studies, 44 (33%) focused on prognosis prediction, 24 (18%) on treatment response prediction, 13 (10%) on adverse event prediction, five (4%) on dose distribution prediction, and 47 (35%) on target volume delineation. Target volume delineation and dose prediction were performed using deep Learning methods. For the prediction of treatment response, prognosis, and adverse events, 57 studies (70%) used conventional radiomics methods, 13 (16%) used deep Learning methods, 8 (10%) used spatial-related unconventional radiomics methods, and 3 (4%) used temporal-related unconventional radiomics methods. In cervical and endometrial cancers, target prediction mostly included treatment response, overall survival, recurrence, toxicity undergoing radiotherapy, lymph node metastasis, and dose distribution. For ovarian cancer, the target prediction included platinum sensitivity and postoperative complications. The majority of the studies were single-center, retrospective, and small-scale; 101 studies (76%) had single-center data, 125 studies (94%) were retrospective, and 127 studies (95%) included Less than 500 cases. The application of AI in assisting treatment in gynecological oncology remains limited. Although the results of AI in predicting the response, prognosis, adverse events, and dose distribution in gynecological oncology are superior, it is evident that there is no validation of substantial data from multiple centers for these tasks.
- 6 June 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 39 (2) , 1155-1167
Automatic Segmentation of Ultrasound-Guided Transverse Thoracic Plane Block Using Convolutional Neural Networks
Ultrasound-guided transverse thoracic plane (TTP) block has been shown to be highly effective in relieving postoperative pain in a variety of surgeries involving the anterior chest wall. Accurate identification of the target structure on ultrasound images is key to the successful implementation of TTP block. Nevertheless, the complexity of anatomical structures in the targeted blockade area coupled with the potential for adverse clinical incidents presents considerable challenges, particularly for anesthesiologists who are less experienced. This study applied deep learning methods to TTP block and developed a deep learning model to achieve real-time region segmentation in ultrasound to assist doctors in the accurate identification of the target nerve. Using 2329 images from 155 patients, we successfully segmented key structures associated with TTP areas and nerve blocks, including the transversus thoracis muscle, lungs, and bones. The achieved IoU (Intersection over Union) scores are 0.7272, 0.9736, and 0.8244 in that order. Recall metrics were 0.8305, 0.9896, and 0.9336 respectively, whilst Dice coefficients reached 0.8421, 0.9866, and 0.9037, particularly with an accuracy surpassing 97% in the identification of perilous lung regions. The real-time segmentation frame rate of the model for ultrasound video was as high as 42.7 fps, thus meeting the exigencies of performing nerve blocks under real-time ultrasound guidance in clinical practice. This study introduces TTP-Unet, a deep learning model specifically designed for TTP block, capable of automatically identifying crucial anatomical structures within ultrasound images of TTP block, thereby offering a practicable solution to attenuate the clinical difficulty associated with TTP block technique.
- 6 June 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 39 (2) , 1155-1167
Automatic Segmentation of Ultrasound-Guided Transverse Thoracic Plane Block Using Convolutional Neural Networks
Ultrasound-guided transverse thoracic plane (TTP) block has been shown to be highly effective in relieving postoperative pain in a variety of surgeries involving the anterior chest wall. Accurate identification of the target structure on ultrasound images is key to the successful implementation of TTP block. Nevertheless, the complexity of anatomical structures in the targeted blockade area coupled with the potential for adverse clinical incidents presents considerable challenges, particularly for anesthesiologists who are less experienced. This study applied deep learning methods to TTP block and developed a deep learning model to achieve real-time region segmentation in ultrasound to assist doctors in the accurate identification of the target nerve. Using 2329 images from 155 patients, we successfully segmented key structures associated with TTP areas and nerve blocks, including the transversus thoracis muscle, lungs, and bones. The achieved IoU (Intersection over Union) scores are 0.7272, 0.9736, and 0.8244 in that order. Recall metrics were 0.8305, 0.9896, and 0.9336 respectively, whilst Dice coefficients reached 0.8421, 0.9866, and 0.9037, particularly with an accuracy surpassing 97% in the identification of perilous lung regions. The real-time segmentation frame rate of the model for ultrasound video was as high as 42.7 fps, thus meeting the exigencies of performing nerve blocks under real-time ultrasound guidance in clinical practice. This study introduces TTP-Unet, a deep learning model specifically designed for TTP block, capable of automatically identifying crucial anatomical structures within ultrasound images of TTP block, thereby offering a practicable solution to attenuate the clinical difficulty associated with TTP block technique.
- 25 September 2024
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (3) , 1362-1373
Automatic Segmentation of Ultrasound-Guided Quadratus Lumborum Blocks Based on Artificial Intelligence
Ultrasound-guided quadratus lumborum block (QLB) technology has become a widely used perioperative analgesia method during abdominal and pelvic surgeries. Due to the anatomical complexity and individual variability of the quadratus lumborum muscle (QLM) on ultrasound images, nerve blocks heavily rely on anesthesiologist experience. Therefore, using artificial intelligence (AI) to identify different tissue regions in ultrasound images is crucial. In our study, we retrospectively collected 112 patients (3162 images) and developed a deep learning model named Q-VUM, which is a U-shaped network based on the Visual Geometry Group 16 (VGG16) network. Q-VUM precisely segments various tissues, including the QLM, the external oblique muscle, the internal oblique muscle, the transversus abdominis muscle (collectively referred to as the EIT), and the bones. Furthermore, we evaluated Q-VUM. Our model demonstrated robust performance, achieving mean intersection over union (mIoU), mean pixel accuracy, dice coefficient, and accuracy values of 0.734, 0.829, 0.841, and 0.944, respectively. The IoU, recall, precision, and dice coefficient achieved for the QLM were 0.711, 0.813, 0.850, and 0.831, respectively. Additionally, the Q-VUM predictions showed that 85% of the pixels in the blocked area fell within the actual blocked area. Finally, our model exhibited stronger segmentation performance than did the common deep learning segmentation networks (0.734 vs. 0.720 and 0.720, respectively). In summary, we proposed a model named Q-VUM that can accurately identify the anatomical structure of the quadratus lumborum in real time. This model aids anesthesiologists in precisely locating the nerve block site, thereby reducing potential complications and enhancing the effectiveness of nerve block procedures.
- 25 September 2024
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (3) , 1362-1373
Automatic Segmentation of Ultrasound-Guided Quadratus Lumborum Blocks Based on Artificial Intelligence
Ultrasound-guided quadratus lumborum block (QLB) technology has become a widely used perioperative analgesia method during abdominal and pelvic surgeries. Due to the anatomical complexity and individual variability of the quadratus lumborum muscle (QLM) on ultrasound images, nerve blocks heavily rely on anesthesiologist experience. Therefore, using artificial intelligence (AI) to identify different tissue regions in ultrasound images is crucial. In our study, we retrospectively collected 112 patients (3162 images) and developed a deep learning model named Q-VUM, which is a U-shaped network based on the Visual Geometry Group 16 (VGG16) network. Q-VUM precisely segments various tissues, including the QLM, the external oblique muscle, the internal oblique muscle, the transversus abdominis muscle (collectively referred to as the EIT), and the bones. Furthermore, we evaluated Q-VUM. Our model demonstrated robust performance, achieving mean intersection over union (mIoU), mean pixel accuracy, dice coefficient, and accuracy values of 0.734, 0.829, 0.841, and 0.944, respectively. The IoU, recall, precision, and dice coefficient achieved for the QLM were 0.711, 0.813, 0.850, and 0.831, respectively. Additionally, the Q-VUM predictions showed that 85% of the pixels in the blocked area fell within the actual blocked area. Finally, our model exhibited stronger segmentation performance than did the common deep learning segmentation networks (0.734 vs. 0.720 and 0.720, respectively). In summary, we proposed a model named Q-VUM that can accurately identify the anatomical structure of the quadratus lumborum in real time. This model aids anesthesiologists in precisely locating the nerve block site, thereby reducing potential complications and enhancing the effectiveness of nerve block procedures.
- Open Access
- 18 September 2024
- Published by Springer Nature in Italian Journal of Pediatrics
- Vol. 50 (1) , 1-10
Progression prediction of coronary artery lesions by echocardiography-based ultrasomics analysis in Kawasaki disease
Background: Echocardiography-based ultrasomics analysis aids Kawasaki disease (KD) diagnosis but its role in predicting coronary artery lesions (CALs) progression remains unknown. We aimed to develop and validate a predictive model combining echocardiogram-based ultrasomics with clinical parameters for CALs progression in KD. Methods: Total 371 KD patients with CALs at baseline were enrolled from a retrospective cohort (cohort 1, n = 316) and a prospective cohort (cohort 2, n = 55). CALs progression was defined by increased Z scores in any coronary artery branch at the 1-month follow-up. Patients in cohort 1 were split randomly into training and validation set 1 at the ratio of 6:4, while cohort 2 comprised validation set 2. Clinical parameters and ultrasomics features at baseline were analyzed and selected for models construction. Model performance was evaluated by area under the receiver operating characteristic curve (AUROC), area under the precision-recall curve (AUPRC) and decision curve analysis (DCA) in the training and two validation sets. Results: At the 1-month follow-ups, 65 patients presented with CALs progression. Three clinical parameters and six ultrasomics features were selected to construct the model. The clinical-ultrasomics model exhibited a good predictive capability in the training, validation set 1 and set 2, achieving AUROCs of 0.83 (95% CI, 0.75–0.90), 0.84 (95% CI, 0.74–0.94), and 0.73 (95% CI, 0.40–0.86), respectively. Moreover, the AUPRC values and DCA of three model demonstrated that the clinical-ultrasomics model consistently outperformed both the clinical model and the ultrasomics model across all three sets, including the training set and the two validation sets. Conclusions: Our study demonstrated the effective predictive capacity of a prediction model combining echocardiogram-based ultrasomics features and clinical parameters in predicting CALs progression in KD.
- 18 September 2024
- Published by Springer Nature in Italian Journal of Pediatrics
- Vol. 50 (1) , 1-10
Open AccessProgression prediction of coronary artery lesions by echocardiography-based ultrasomics analysis in Kawasaki disease
Background: Echocardiography-based ultrasomics analysis aids Kawasaki disease (KD) diagnosis but its role in predicting coronary artery lesions (CALs) progression remains unknown. We aimed to develop and validate a predictive model combining echocardiogram-based ultrasomics with clinical parameters for CALs progression in KD. Methods: Total 371 KD patients with CALs at baseline were enrolled from a retrospective cohort (cohort 1, n = 316) and a prospective cohort (cohort 2, n = 55). CALs progression was defined by increased Z scores in any coronary artery branch at the 1-month follow-up. Patients in cohort 1 were split randomly into training and validation set 1 at the ratio of 6:4, while cohort 2 comprised validation set 2. Clinical parameters and ultrasomics features at baseline were analyzed and selected for models construction. Model performance was evaluated by area under the receiver operating characteristic curve (AUROC), area under the precision-recall curve (AUPRC) and decision curve analysis (DCA) in the training and two validation sets. Results: At the 1-month follow-ups, 65 patients presented with CALs progression. Three clinical parameters and six ultrasomics features were selected to construct the model. The clinical-ultrasomics model exhibited a good predictive capability in the training, validation set 1 and set 2, achieving AUROCs of 0.83 (95% CI, 0.75–0.90), 0.84 (95% CI, 0.74–0.94), and 0.73 (95% CI, 0.40–0.86), respectively. Moreover, the AUPRC values and DCA of three model demonstrated that the clinical-ultrasomics model consistently outperformed both the clinical model and the ultrasomics model across all three sets, including the training set and the two validation sets. Conclusions: Our study demonstrated the effective predictive capacity of a prediction model combining echocardiogram-based ultrasomics features and clinical parameters in predicting CALs progression in KD.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (10) , 2889-2899
Space-Specific Mixing Excitation for High-SNR Spatial Encoding in Magnetic Particle Imaging
Objective: Magnetic Particle Imaging (MPI) is a radiation-free tracer-based imaging technology that visualizes the spatial distribution of superparamagnetic iron oxide nanoparticles. Conventional spatial encoding methods in MPI rely on a gradient magnetic field with a constant gradient strength to generate a field-free point or line for spatial scanning. However, increasing the gradient strength can enhance theoretical spatial resolution but also lead to a decrease in the Signal-to-Noise Ratio (SNR) and sensitivity of the imaging system. This poses a technical challenge in balancing spatial resolution and sensitivity, necessitating intricate hardware design. Methods: To address this, we present a Space-Specific Mixing Excitation (SSME) technique for achieving high-SNR spatial encoding in MPI. By utilizing a dual-frequency excitation magnetic field with a non-homogeneous field strength, magnetic particles at each position generate unique intermodulation responses. By performing multi-channel acquisitions across the entire field of view, high SNR MPI signals can be acquired. When combined with reconstruction techniques based on system matrix, multi-dimensional SSME-MPI can be achieved. Results: The effectiveness of the proposed method was validated through phantom and in vivo imaging experiments. The results demonstrate significant improvements in sensitivity (3.6-fold improvement) and spatial resolution (better than 1 mm) without any hardware modifications. Conclusion: These findings demonstrate the capability of SSME to enhance both the spatial resolution and sensitivity of MPI. Significance: This method provides a solution to the ongoing challenge of balancing spatial resolution and sensitivity in MPI, potentially facilitating the implementation of MPI in a wider range of medical applications.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (10) , 2889-2899
Space-Specific Mixing Excitation for High-SNR Spatial Encoding in Magnetic Particle Imaging
Objective: Magnetic Particle Imaging (MPI) is a radiation-free tracer-based imaging technology that visualizes the spatial distribution of superparamagnetic iron oxide nanoparticles. Conventional spatial encoding methods in MPI rely on a gradient magnetic field with a constant gradient strength to generate a field-free point or line for spatial scanning. However, increasing the gradient strength can enhance theoretical spatial resolution but also lead to a decrease in the Signal-to-Noise Ratio (SNR) and sensitivity of the imaging system. This poses a technical challenge in balancing spatial resolution and sensitivity, necessitating intricate hardware design. Methods: To address this, we present a Space-Specific Mixing Excitation (SSME) technique for achieving high-SNR spatial encoding in MPI. By utilizing a dual-frequency excitation magnetic field with a non-homogeneous field strength, magnetic particles at each position generate unique intermodulation responses. By performing multi-channel acquisitions across the entire field of view, high SNR MPI signals can be acquired. When combined with reconstruction techniques based on system matrix, multi-dimensional SSME-MPI can be achieved. Results: The effectiveness of the proposed method was validated through phantom and in vivo imaging experiments. The results demonstrate significant improvements in sensitivity (3.6-fold improvement) and spatial resolution (better than 1 mm) without any hardware modifications. Conclusion: These findings demonstrate the capability of SSME to enhance both the spatial resolution and sensitivity of MPI. Significance: This method provides a solution to the ongoing challenge of balancing spatial resolution and sensitivity in MPI, potentially facilitating the implementation of MPI in a wider range of medical applications.