SASalla Autti

Salla Autti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Salla Autti has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    MEG-informed navigated TMS for individualized speech cortical mapping

    by Salla Autti, Sara Korkealaakso, Juha Gogulski, Melina Engelhardt, Selja Vaalto, Hanna Renvall, Mia Liljeström, Pantelis Lioumis

    Speech cortical mapping by means of navigated repetitive transcranial magnetic stimulation (SCM nrTMS) provides neurosurgeons with noninvasive prior information about individual’s cortical speech network. Individualized mapping is required, since the exact locations and activation patterns of speech production show high variability between individuals. We hypothesized that magnetoencephalography (MEG) data of an individual’s speech production could guide the SCM TMS process temporally and spatially, leading to higher error rates at MEG-defined locations with TMS pulse timings coinciding with MEG activity. 13 healthy subjects participated in MEG and TMS measurements, where the timing of the TMS pulse (PTI; picture-to-TMS interval) was adjusted based on the individual’s MEG activation in a picture naming task. At the group level, significant correlations were observed between the latency of the peak MEG activation and the PTI that produced the highest speech error rate. The MEG peak preceded the best PTI by 132 ms (R=0.713, p =0.006) across the entire stimulation area in the lateral left hemisphere, and by 103 ms (R=0.673, p =0.012) in the left frontal regions. We found 17 combinations of PTI and stimulation area in which the subject’s speech error rate increased significantly compared to their average error rate. Our findings suggest that optimal PTIs are highly individual, and that individualizing the PTI according to MEG activation provides a straightforward method for accounting individual variability in speech function and may increase the sensitivity and utility of SCM TMS.

  • Open Access

    fMRI analysis parameters affect the concordance with TMS in noninvasive speech mapping

    by J Gogulski, S Autti, M Vasileiadi, M Tik, S Vaalto, H Renvall, M Liljeström, P Lioumis

    Background: Speech cortical mapping (SCM) conducted with widely available functional MRI (fMRI) can yield divergent results compared to the more commonly used navigated TMS (nTMS). The impact of specific fMRI task paradigms and preprocessing choices on reaching similarity with nTMS has not been explored before. Objective: To test how the fMRI experimental task and spatial smoothing of the data compare with nTMS-based results, to subsequently increase the reliability of object naming fMRI for SCM. Methods: Thirteen healthy, right-handed Finnish speakers underwent an nTMS-based SCM experiment in which the left hemisphere was stimulated while the subjects overtly named common visually presented stimuli. Standard as well as magnetoencephalography-informed picture-to-TMS intervals were applied. The same participants completed fMRI with overt naming, silent naming, and observation tasks on the same stimuli, analyzed with 0-, 3-, and 6-mm spatial smoothing. nTMS-based error and non-error sites were converted to volumetric density maps, and error-specific maps were derived by subtracting non-error from error density. Spatial similarity between binarized fMRI maps and nTMS maps was quantified using Jaccard index. Within-session fMRI reliability was estimated with voxel- and subjectwise concordance correlation coefficients across two separate runs conducted on the same day. Results: Similarity between fMRI and nTMS maps was overall low but depended significantly on data smoothing. Within subjects, mean error-specific Jaccard index was 0.036, with most individuals showing maximal similarity at 6 mm of smoothing. The fMRI task resulting in highest similarity with the nTMS map varied across participants, but at the group level, silent naming with 6-mm smoothing yielded the best correspondence. In general, within-session fMRI reliability increased with greater smoothing. Conclusion: The amount of applied fMRI data smoothing shapes the agreement of fMRI and nTMS maps during SCM. Silent naming fMRI combined with 6-mm data smoothing yielded the highest overlap with nTMS maps, yet the effect of the experimental task was statistically non-significant and the absolute similarity of the maps remained low. These results underline the different views to brain functions provided by direct perturbation of neural functions vs. blood-oxygenation based fMRI, and offer practical guidance when combining fMRI with nTMS in noninvasive speech cortical mapping. Highlights: Correspondence of fMRI and TMS speech cortical mapping results varied across individuals Concordance between the methods was generally low and depended on the fMRI data smoothing Silent naming task in fMRI, combined with 6-mm data smoothing, yielded highest similarity to nTMS Within-session fMRI reliability increased with greater smoothing

  • Open Access

    Automated speech artefact removal from MEG data utilizing facial gestures and mutual information

    by Sara Tuomaala, Salla Autti, Silvia Federica Cotroneo, Pantelis Lioumis, Hanna Renvall, Mia Liljeström

    The ability to speak is one of the most crucial human skills, motivating neuroscientific studies of speech production and speech-related neural dynamics. Increased knowledge in this area allows, for example, for development of rehabilitation protocols for language-related disorders. While our understanding of speech-related neural processes has been greatly enhanced owing to non-invasive neuroimaging techniques, the interpretations have been limited by speech artefacts caused by the activation of facial muscles that mask important language-related information. Despite earlier approaches applying independent component analysis (ICA), the artefact removal process continues to be time consuming, poorly replicable, and affected by inconsistencies between different observers, typically requiring manual selection of artefactual components. The artefact component selection criteria have been variable, leading to non-standardized speech artefact removal processes. To address these issues, we propose here a pipeline for automated speech artefact removal from magnetoencephalography (MEG) data. We developed an ICA-based speech artefact removal routine by utilizing electromyography (EMG) data measured from facial muscles during a facial gesture task for isolating the speech-induced artefacts. Additionally, we used mutual information (MI) as a similarity measure between the EMG signals and the ICA-decomposed MEG to provide a feasible way to identify the artefactual components. Our approach efficiently and in an automated manner removed speech artefacts from MEG data. The method can be feasibly applied to improve the understanding of speech-related cortical dynamics, while transparently evaluating the removed and preserved MEG activation.


  • Open Access

    Automated speech artefact removal from MEG data utilizing facial gestures and mutual information

    by Sara Tuomaala, Salla Autti, Silvia Federica Cotroneo, Pantelis Lioumis, Hanna Renvall, Mia Liljeström

    The ability to speak is one of the most crucial human skills, motivating neuroscientific studies of speech production and speech-related neural dynamics. Increased knowledge in this area, allows e.g., for development of rehabilitation protocols for language-related disorders. While our understanding of speech-related neural processes has greatly enhanced owing to non-invasive neuroimaging techniques, the interpretations have been limited by speech artefacts caused by the activation of facial muscles that mask important languagerelated information. Despite earlier approaches applying independent component analysis (ICA), the artefact removal process continues to be time-consuming, poorly replicable and affected by inconsistencies between different observers, typically requiring manual selection of artefactual components. The artefact component selection criteria have been variable, leading to non-standardized speech artefact removal processes. To address these issues, we propose here a pipeline for automated speech artefact removal from MEG data. We developed an ICA-based speech artefact removal routine by utilizing EMG data measured from facial muscles during a facial gesture task for isolating the speech-induced artefacts. Additionally, we used mutual information (MI) as a similarity measure between the EMG signals and the ICA-decomposed MEG to provide a feasible way to identify the artefactual components. Our approach efficiently and in an automated manner removed speech artefacts from MEG data. The method can be feasibly applied to improve the understanding of speech-related cortical dynamics, while transparently evaluating the removed and preserved MEG activation.