ZDZhen Dai

Zhen Dai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhen Dai has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Individually Modified Microneedle Array for Minimal Invasive Multi-Electrolyte Monitoring

    by Ketian Yu, Yukun Ma, Yiming Wei, Wanying Chen, Zhen Dai, Yu Cai, Xuesong Ye, Bo Liang

    Electrolytes play crucial roles in regulating nerve and muscle functions. Currently, microneedle technology enables real-time electrolyte monitoring through minimally invasive methods. However, due to the small size of microneedles, performing multi-layer modifications on individual microneedles and ensuring the integrity of these layers pose significant challenges. Additionally, the puncture efficiency of the electrodes will be affected by the structure of microneedle array integration. To address these issues, we primarily focus on developing a multi-parameter ion monitoring system based on microneedle arrays. By optimizing the surface reconstruction of electrode substrates, the adhesion between the electrode surface and the modification layer was improved, enhancing the stability of the electrodes. Potassium, sodium, and calcium ion-selective electrodes based on microneedles were fabricated, demonstrating good sensitivity and linearity. To tackle the puncture efficiency of microneedle arrays, finite element simulation was employed to investigate the mechanical properties of different structural designs of microneedle arrays during skin insertion. Ultimately, an integrated microneedle array was designed and assembled, and a multi-parameter ion monitoring system was developed, validated through in vitro simulations and in vivo animal experiments. This research provides valuable insights into the development and advancement of minimally invasive, multi-parameter dynamic monitoring technologies in clinical settings.


  • Open Access

    Optimizing Magnetic Separation and Cleaning Module in Fully Automated Chemiluminescence Immunoassay Analyzer Using a Special Arrangement of Spliced Magnets and a Three-Stage Magnetic Bead Collection Method

    by Chuan Lyu, Yu Jiang, Zhen Dai, Xu Xu, Yu Cai, Bo Liang, Congcong Zhou, Xuesong Ye, Jing Wang

    The magnetic separation and cleaning module, as a core component of the fully automated chemiluminescence immunoassay (CLIA) analyzer, encounters issues including high magnetic bead loss rate, long cleaning time, and poor cleaning effect. Based on a simulation analysis using COMSOL, we proposed a novel magnetic separation and cleaning module applied to a fully automated CLIA analyzer. The module adopted a method of arranging spliced rectangular magnets on opposite sides, where the same polarity faced each other, as well as a three-stage magnetic bead collection method. With the proposed method, the total cleaning process can be accomplished within 225 s; the total magnetic bead loss rate over three rounds of cleaning is 6.03%, whereas that of traditional instruments is 25.85%; the coefficient of variation (CV) of the magnetic bead loss rate is less than 0.5%; effective cleaning of free markers is achieved under various sample conditions. Compared with traditional CLIA instruments, this method comprehensively improves key performance indicators of the magnetic separation and cleaning module, providing a reference for similar modules in fully automated CLIA analyzers and positively impacting the accuracy of CLIA for the detection of disease biomarkers.