XXXu Xu

Xu Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xu Xu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Gray Wolf Optimization-Long Short-Term Memory Based Temperature Estimation and Closed-Loop Control Method in Microfluidic Chemiluminescence Immunoassay

    by Xu Xu, Zhongyi Xu, Chuan Lyu, Bo Liang, Congcong Zhou, Xuesong Ye, Jing Wang

    Driven by the rising demand for point-of-care testing (POCT) in aging societies, accurate temperature regulation of reaction solutions has become a core technical bottleneck for miniaturized chemiluminescence immunoassay systems, since conventional indirect control strategies inevitably produce systematic deviations. To tackle this challenge, we present an integrated solution that couples multiphysics simulation, data-driven temperature estimation modeling, and embedded hardware design. We constructed a COMSOL heat transfer model to analyze the thermal performance of the microfluidic chip. Meanwhile, a grey wolf optimization (GWO) enhanced long short-term memory (LSTM) network was developed to infer the unmeasured actual reaction solution temperature based on accessible parameters, including heating voltage, ambient temperature and substrate temperature. The obtained temperature estimation was then fed back to a fuzzy PID controller for closed-loop regulation. Experimental results demonstrated that the GWO-LSTM model limited the estimation error within 0.3 °C, and the steady-state temperature control accuracy reached ±0.2 °C or higher under fluctuating ambient conditions and diverse initial states. For cardiac troponin I (cTnI) detection, the proposed system shortened the incubation duration and reduced the coefficient of variation from 10.77% to 2.69%. This work addresses the key bottleneck restricting precise temperature control in microfluidic chemiluminescence analyzers, which provides robust technical support for the development of next-generation high-performance POCT instruments.

  • Open Access

    Optimizing Magnetic Separation and Cleaning Module in Fully Automated Chemiluminescence Immunoassay Analyzer Using a Special Arrangement of Spliced Magnets and a Three-Stage Magnetic Bead Collection Method

    by Chuan Lyu, Yu Jiang, Zhen Dai, Xu Xu, Yu Cai, Bo Liang, Congcong Zhou, Xuesong Ye, Jing Wang

    The magnetic separation and cleaning module, as a core component of the fully automated chemiluminescence immunoassay (CLIA) analyzer, encounters issues including high magnetic bead loss rate, long cleaning time, and poor cleaning effect. Based on a simulation analysis using COMSOL, we proposed a novel magnetic separation and cleaning module applied to a fully automated CLIA analyzer. The module adopted a method of arranging spliced rectangular magnets on opposite sides, where the same polarity faced each other, as well as a three-stage magnetic bead collection method. With the proposed method, the total cleaning process can be accomplished within 225 s; the total magnetic bead loss rate over three rounds of cleaning is 6.03%, whereas that of traditional instruments is 25.85%; the coefficient of variation (CV) of the magnetic bead loss rate is less than 0.5%; effective cleaning of free markers is achieved under various sample conditions. Compared with traditional CLIA instruments, this method comprehensively improves key performance indicators of the magnetic separation and cleaning module, providing a reference for similar modules in fully automated CLIA analyzers and positively impacting the accuracy of CLIA for the detection of disease biomarkers.