Latest Publications
- Open Access
- 17 October 2024
- Published by MDPI AG in Information
- Vol. 15 (10) , 650
A Method for Single-Phase Ground Fault Section Location in Distribution Networks Based on Improved Empirical Wavelet Transform and Graph Isomorphic Networks
When single-phase ground faults occur in distribution systems, the fault characteristics of zero-sequence current signals are not prominent. They are quickly submerged in noise, leading to difficulties in fault section location. This paper proposes a method for fault section location in distribution networks based on improved empirical wavelet transform (IEWT) and GINs to address this issue. Firstly, based on kurtosis, EWT is optimized using the N-point search method to decompose the zero-sequence current signal into modal components. Noise is filtered out through weighted permutation entropy (WPE), and signal reconstruction is performed to obtain the denoised zero-sequence current signal. Subsequently, GINs are employed for graph classification tasks. According to the topology of the distribution network, the corresponding graph is constructed as the input to the GIN. The denoised zero-sequence current signal is the node input for the GIN. The GIN autonomously explores the features of each graph structure to achieve fault section location. The experimental results demonstrate that this method has strong noise resistance, with a fault section location accuracy of up to 99.95%, effectively completing fault section location in distribution networks.
- 17 October 2024
- Published by MDPI AG in Information
- Vol. 15 (10) , 650
Open AccessA Method for Single-Phase Ground Fault Section Location in Distribution Networks Based on Improved Empirical Wavelet Transform and Graph Isomorphic Networks
When single-phase ground faults occur in distribution systems, the fault characteristics of zero-sequence current signals are not prominent. They are quickly submerged in noise, leading to difficulties in fault section location. This paper proposes a method for fault section location in distribution networks based on improved empirical wavelet transform (IEWT) and GINs to address this issue. Firstly, based on kurtosis, EWT is optimized using the N-point search method to decompose the zero-sequence current signal into modal components. Noise is filtered out through weighted permutation entropy (WPE), and signal reconstruction is performed to obtain the denoised zero-sequence current signal. Subsequently, GINs are employed for graph classification tasks. According to the topology of the distribution network, the corresponding graph is constructed as the input to the GIN. The denoised zero-sequence current signal is the node input for the GIN. The GIN autonomously explores the features of each graph structure to achieve fault section location. The experimental results demonstrate that this method has strong noise resistance, with a fault section location accuracy of up to 99.95%, effectively completing fault section location in distribution networks.
- Open Access
Fault-Line Selection Method in Active Distribution Networks Based on Improved Multivariate Variational Mode Decomposition and Lightweight YOLOv10 Network
In active distribution networks (ADNs), the extensive deployment of distributed generations (DGs) heightens system nonlinearity and non-stationarity, which can weaken fault characteristics and reduce fault detection accuracy. To improve fault detection accuracy in distribution networks, a method combining improved multivariate variational mode decomposition (IMVMD) and YOLOv10 network for active distribution network fault detection is proposed. Firstly, an MVMD method optimized by the northern goshawk optimization (NGO) algorithm named IMVMD is introduced to adaptively decompose zero-sequence currents at both ends of line sources and loads into intrinsic mode functions (IMFs). Secondly, considering the spatio-temporal correlation between line sources and loads, a dynamic time warping (DTW) algorithm is utilized to determine the optimal alignment path time series for corresponding IMFs at both ends. Then, the Markov transition field (MTF) transforms the 1D time series into 2D spatio-temporal images, and the MTF images of all lines are concatenated to obtain a comprehensive spatio-temporal feature map of the distribution network. Finally, using the spatio-temporal feature map as input, the lightweight YOLOv10 network autonomously extracts fault features to achieve precise fault-line selection. Experimental results demonstrate the robustness of the proposed method, achieving a fault detection accuracy of 99.88%, which can ensure accurate fault-line selection under complex scenarios involving simultaneous phase-to-ground faults at two points.
Open AccessFault-Line Selection Method in Active Distribution Networks Based on Improved Multivariate Variational Mode Decomposition and Lightweight YOLOv10 Network
In active distribution networks (ADNs), the extensive deployment of distributed generations (DGs) heightens system nonlinearity and non-stationarity, which can weaken fault characteristics and reduce fault detection accuracy. To improve fault detection accuracy in distribution networks, a method combining improved multivariate variational mode decomposition (IMVMD) and YOLOv10 network for active distribution network fault detection is proposed. Firstly, an MVMD method optimized by the northern goshawk optimization (NGO) algorithm named IMVMD is introduced to adaptively decompose zero-sequence currents at both ends of line sources and loads into intrinsic mode functions (IMFs). Secondly, considering the spatio-temporal correlation between line sources and loads, a dynamic time warping (DTW) algorithm is utilized to determine the optimal alignment path time series for corresponding IMFs at both ends. Then, the Markov transition field (MTF) transforms the 1D time series into 2D spatio-temporal images, and the MTF images of all lines are concatenated to obtain a comprehensive spatio-temporal feature map of the distribution network. Finally, using the spatio-temporal feature map as input, the lightweight YOLOv10 network autonomously extracts fault features to achieve precise fault-line selection. Experimental results demonstrate the robustness of the proposed method, achieving a fault detection accuracy of 99.88%, which can ensure accurate fault-line selection under complex scenarios involving simultaneous phase-to-ground faults at two points.