Latest Publications
- Open Access
A High-Impedance Fault Detection Method for Active Distribution Networks Based on Time–Frequency–Space Domain Fusion Features and Hybrid Convolutional Neural Network
Traditional methods for detecting high-impedance faults (HIFs) in distribution networks primarily rely on constructing fault diagnosis models using one-dimensional zero-sequence current sequences. A single diagnostic model often limits the deep exploration of fault characteristics. To improve the accuracy of HIF detection, a new method for detecting HIFs in active distribution networks is proposed. First, by applying continuous wavelet transform (CWT) to the collected zero-sequence currents under various operating conditions, the time–frequency spectrum (TFS) is obtained. An optimized algorithm, modified empirical wavelet transform (MEWT), is then used to denoise the zero-sequence current signals, resulting in a series of intrinsic mode functions (IMFs). Secondly, the intrinsic mode functions (IMFs) are transformed into a two-dimensional spatial domain fused image using the symmetric dot pattern (SDP). Finally, the TFS and SDP images are synchronized as inputs to a hybrid convolutional neural network (Hybrid-CNN) to fully explore the system’s fault features. The Sigmoid function is utilized to achieve HIF detection, followed by simulation and experimental validation. The results indicate that the proposed method can effectively overcome the issues of traditional methods, achieving a detection accuracy of up to 98.85% across different scenarios, representing a 2–7% improvement over single models.
Open AccessA High-Impedance Fault Detection Method for Active Distribution Networks Based on Time–Frequency–Space Domain Fusion Features and Hybrid Convolutional Neural Network
Traditional methods for detecting high-impedance faults (HIFs) in distribution networks primarily rely on constructing fault diagnosis models using one-dimensional zero-sequence current sequences. A single diagnostic model often limits the deep exploration of fault characteristics. To improve the accuracy of HIF detection, a new method for detecting HIFs in active distribution networks is proposed. First, by applying continuous wavelet transform (CWT) to the collected zero-sequence currents under various operating conditions, the time–frequency spectrum (TFS) is obtained. An optimized algorithm, modified empirical wavelet transform (MEWT), is then used to denoise the zero-sequence current signals, resulting in a series of intrinsic mode functions (IMFs). Secondly, the intrinsic mode functions (IMFs) are transformed into a two-dimensional spatial domain fused image using the symmetric dot pattern (SDP). Finally, the TFS and SDP images are synchronized as inputs to a hybrid convolutional neural network (Hybrid-CNN) to fully explore the system’s fault features. The Sigmoid function is utilized to achieve HIF detection, followed by simulation and experimental validation. The results indicate that the proposed method can effectively overcome the issues of traditional methods, achieving a detection accuracy of up to 98.85% across different scenarios, representing a 2–7% improvement over single models.
- Open Access
- 17 October 2024
- Published by MDPI AG in Information
- Vol. 15 (10) , 650
A Method for Single-Phase Ground Fault Section Location in Distribution Networks Based on Improved Empirical Wavelet Transform and Graph Isomorphic Networks
When single-phase ground faults occur in distribution systems, the fault characteristics of zero-sequence current signals are not prominent. They are quickly submerged in noise, leading to difficulties in fault section location. This paper proposes a method for fault section location in distribution networks based on improved empirical wavelet transform (IEWT) and GINs to address this issue. Firstly, based on kurtosis, EWT is optimized using the N-point search method to decompose the zero-sequence current signal into modal components. Noise is filtered out through weighted permutation entropy (WPE), and signal reconstruction is performed to obtain the denoised zero-sequence current signal. Subsequently, GINs are employed for graph classification tasks. According to the topology of the distribution network, the corresponding graph is constructed as the input to the GIN. The denoised zero-sequence current signal is the node input for the GIN. The GIN autonomously explores the features of each graph structure to achieve fault section location. The experimental results demonstrate that this method has strong noise resistance, with a fault section location accuracy of up to 99.95%, effectively completing fault section location in distribution networks.
- 17 October 2024
- Published by MDPI AG in Information
- Vol. 15 (10) , 650
Open AccessA Method for Single-Phase Ground Fault Section Location in Distribution Networks Based on Improved Empirical Wavelet Transform and Graph Isomorphic Networks
When single-phase ground faults occur in distribution systems, the fault characteristics of zero-sequence current signals are not prominent. They are quickly submerged in noise, leading to difficulties in fault section location. This paper proposes a method for fault section location in distribution networks based on improved empirical wavelet transform (IEWT) and GINs to address this issue. Firstly, based on kurtosis, EWT is optimized using the N-point search method to decompose the zero-sequence current signal into modal components. Noise is filtered out through weighted permutation entropy (WPE), and signal reconstruction is performed to obtain the denoised zero-sequence current signal. Subsequently, GINs are employed for graph classification tasks. According to the topology of the distribution network, the corresponding graph is constructed as the input to the GIN. The denoised zero-sequence current signal is the node input for the GIN. The GIN autonomously explores the features of each graph structure to achieve fault section location. The experimental results demonstrate that this method has strong noise resistance, with a fault section location accuracy of up to 99.95%, effectively completing fault section location in distribution networks.