Da Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Da Xu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Jianhua Yang
3 shared publicationsJierui Zhang
3 shared publications- Shi Liu
Jilin Province Engineering Research Center
3 shared publications Yao Meng
Jilin Province Engineering Research Center
3 shared publicationsYutian Peng
3 shared publications- Gaofei Sun
Jilin Province Engineering Research Center
2 shared publications
Latest Publications
- 26 January 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (18) , 34835
Research on methods for improving irradiance uniformity based on the analysis of the energy transmission characteristics of solar simulator
Aiming at the issue that the irradiance uniformity of the existing solar simulator is difficult to enhance further, based on the theories of geometrical and matrix optics, the characteristics of energy transmission in the optical system of the solar simulator were analyzed. The influence of the optical axis offsets of each subsystem on the irradiance non-uniformity was studied by using LightTools. Based on the analysis and research of the energy transmission characteristics, a method for optical axis calibration was proposed. The total optical axis offset was fitted by the least squares method to obtain the curve of irradiance non-uniformity change. Finally, a calibration experiment of the optical axis was established to verify and test the irradiance distribution and calculate the irradiance non-uniformity. The results show that compared with the traditional self-collimation-based solar simulator optical axis calibration method, the irradiance non-uniformity within 100 mm × 100 mm of the square facula is 0.86%, and the irradiance uniformity of the solar simulator has been further improved.
- 26 January 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (18) , 34835
Research on methods for improving irradiance uniformity based on the analysis of the energy transmission characteristics of solar simulator
Aiming at the issue that the irradiance uniformity of the existing solar simulator is difficult to enhance further, based on the theories of geometrical and matrix optics, the characteristics of energy transmission in the optical system of the solar simulator were analyzed. The influence of the optical axis offsets of each subsystem on the irradiance non-uniformity was studied by using LightTools. Based on the analysis and research of the energy transmission characteristics, a method for optical axis calibration was proposed. The total optical axis offset was fitted by the least squares method to obtain the curve of irradiance non-uniformity change. Finally, a calibration experiment of the optical axis was established to verify and test the irradiance distribution and calculate the irradiance non-uniformity. The results show that compared with the traditional self-collimation-based solar simulator optical axis calibration method, the irradiance non-uniformity within 100 mm × 100 mm of the square facula is 0.86%, and the irradiance uniformity of the solar simulator has been further improved.
- 21 November 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (23) , 6705-6708
Research on the aperture angle-matched collimated illumination method for the dark-state light leakage of LCD target simulators
Aiming at the problem of overbrightness of the target simulator background for LED backlight panel illumination, a 5° aperture angle-matched collimated illumination method for the target simulator is proposed based on the study of the dark-state leakage of the LCD display device and the scattered stray light of the system. After simulation analysis the method can make the display contrast increase by 3.1 times and solve the problem of dark targets being drowned by the background bright light, which exists in the LED illumination target simulator. It is experimentally verified that the target simulator using the aperture angle-matched collimated illumination method shows a 2.8 times improvement in SNR and effectively reduces the energy of the dark-state background.
- 21 November 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (23) , 6705-6708
Research on the aperture angle-matched collimated illumination method for the dark-state light leakage of LCD target simulators
Aiming at the problem of overbrightness of the target simulator background for LED backlight panel illumination, a 5° aperture angle-matched collimated illumination method for the target simulator is proposed based on the study of the dark-state leakage of the LCD display device and the scattered stray light of the system. After simulation analysis the method can make the display contrast increase by 3.1 times and solve the problem of dark targets being drowned by the background bright light, which exists in the LED illumination target simulator. It is experimentally verified that the target simulator using the aperture angle-matched collimated illumination method shows a 2.8 times improvement in SNR and effectively reduces the energy of the dark-state background.
- 11 October 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (22) , 38879-38895
Research on the simulation method of a BP neural network PID control for stellar spectrum
This study investigated the multiple correlations among spectral simulation units based on digital micromirror device (DMD) spectral simulation, which leads to the problem that conventional spectral simulation methods such as PID control exhibit a low fitting accuracy or long fitting time in the spectral simulation of various targets. In this paper, a method of stellar spectrum simulation based on back propagation neural network-based PID (BP-PID) control is proposed to achieve high efficiency and high precision simulation of various spectral targets. The topology of the BP neural network was constructed based on the spectral modulation model of a DMD stellar spectrum simulation system, and the algorithm of the BP-PID control was designed. Finally, an experimental platform was built to verify the performance and spectral simulation accuracy of the BP-PID control algorithm. The results show that the overshoot and response time of the BP-PID control algorithm decreased by 79.01% and 30%, respectively compared with those of the PID control algorithm. The maximum spectral simulation accuracies of 2000K, 7000K, and 12000K color temperature increased by a factor of 2.311, 1.871, and 2.254, respectively, and the standard deviations of the spectral simulation error decreased by 56%, 41%, and 54%, respectively. In the range of 2000-12000K color temperature, the spectral simulation error of the BP-PID control algorithm is better than ±3.495%, and the standard deviation of the spectral simulation error is between 1.8255 and 2.2358. The proposed method can improve the spectral simulation accuracy and simulation efficiency of a star simulator, reduce the magnitude and spectrum calibration errors caused by the differential response, improve the star feature recognition accuracy of the orbiting star sensor, and hence, provide a theoretical and technical basis for the development of high-precision star sensors.
- 11 October 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (22) , 38879-38895
Research on the simulation method of a BP neural network PID control for stellar spectrum
This study investigated the multiple correlations among spectral simulation units based on digital micromirror device (DMD) spectral simulation, which leads to the problem that conventional spectral simulation methods such as PID control exhibit a low fitting accuracy or long fitting time in the spectral simulation of various targets. In this paper, a method of stellar spectrum simulation based on back propagation neural network-based PID (BP-PID) control is proposed to achieve high efficiency and high precision simulation of various spectral targets. The topology of the BP neural network was constructed based on the spectral modulation model of a DMD stellar spectrum simulation system, and the algorithm of the BP-PID control was designed. Finally, an experimental platform was built to verify the performance and spectral simulation accuracy of the BP-PID control algorithm. The results show that the overshoot and response time of the BP-PID control algorithm decreased by 79.01% and 30%, respectively compared with those of the PID control algorithm. The maximum spectral simulation accuracies of 2000K, 7000K, and 12000K color temperature increased by a factor of 2.311, 1.871, and 2.254, respectively, and the standard deviations of the spectral simulation error decreased by 56%, 41%, and 54%, respectively. In the range of 2000-12000K color temperature, the spectral simulation error of the BP-PID control algorithm is better than ±3.495%, and the standard deviation of the spectral simulation error is between 1.8255 and 2.2358. The proposed method can improve the spectral simulation accuracy and simulation efficiency of a star simulator, reduce the magnitude and spectrum calibration errors caused by the differential response, improve the star feature recognition accuracy of the orbiting star sensor, and hence, provide a theoretical and technical basis for the development of high-precision star sensors.
- 26 September 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (21) , 36708-36728
Research on multi-optical axis online compensation alignment method for space environment simulation system
Aiming at the problem that the error of multi-optical axis alignment is difficult to control in the simulation calibration test, a multi-optical axis dynamic compensation alignment method for the space environment simulation system is proposed. The effect of optical axis disturbance on the signal detection link was analyzed to obtain the alignment accuracy requirements, the optical axis alignment error compensation mechanism was established, the target simulation system with long pupil distance was designed, the alignment error transfer model based on topology structure was constructed, and the test prototype was built. The test results show that the static attitude alignment resolution is better than 3" and the position alignment resolution is better than 11µm. After online compensation, the position error is better than 11.04µm, and the energy error is better than 3.2%, which realizes the online monitoring and compensation of the optical axis alignment error of the ground space environment simulation system.
- 26 September 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (21) , 36708-36728
Research on multi-optical axis online compensation alignment method for space environment simulation system
Aiming at the problem that the error of multi-optical axis alignment is difficult to control in the simulation calibration test, a multi-optical axis dynamic compensation alignment method for the space environment simulation system is proposed. The effect of optical axis disturbance on the signal detection link was analyzed to obtain the alignment accuracy requirements, the optical axis alignment error compensation mechanism was established, the target simulation system with long pupil distance was designed, the alignment error transfer model based on topology structure was constructed, and the test prototype was built. The test results show that the static attitude alignment resolution is better than 3" and the position alignment resolution is better than 11µm. After online compensation, the position error is better than 11.04µm, and the energy error is better than 3.2%, which realizes the online monitoring and compensation of the optical axis alignment error of the ground space environment simulation system.