Vincent Streva
Vincent Streva has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Eric Stern
Selux Diagnostics
2 shared publications - Alamelu Chandrasekaran
The Center for Advanced Laboratory Medicine, Department of Pathology and Cell Biology, Columbia University Irving Medical Center
1 shared publication Amanda Harrington
Department of Pathology and Laboratory Medicine, Loyola University
1 shared publicationAsmae El Ganbour
Selux Diagnostics
1 shared publicationCheryl Jankowsi-Romano
Northwell Health Clinical Laboratories, New York, New York, USA
1 shared publication- Daniel D. Rhoads
Department of Pathology and Laboratory Medicine, Cleveland Clinic
1 shared publication
Latest Publications
- Open Access
- 14 October 2026
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 64 (10)
Benchmarking four commercial antimicrobial susceptibility testing systems and disk diffusion to reference broth microdilution in the assessment of gram-negative bacterial isolates
Commercial antimicrobial susceptibility testing (AST) systems for gram-negative bacteria provide operational advantages over reference broth microdilution (BMD) testing, but the results produced by commercial AST systems might not be as accurate as the reference method. Assessing and comparing the performance of AST systems can be informative for clinical microbiology practice. In total, 280 clinical isolates and 100 isolates from the U.S. Centers for Disease Control and Prevention Antimicrobial Resistance Isolate Bank, including Enterobacterales and Pseudomonas aeruginosa, were intended to be tested using disk diffusion (DD) and automated commercial AST systems, such as Selux AST System (Selux Diagnostics), MicroScan (Beckman Coulter), Phoenix (Becton, Dickinson and Company), and Vitek 2 (bioMérieux). These results were compared to BMD as the reference standard. In total, 372 isolates were assessed. For Enterobacterales, the greatest frequency of very major errors was identified with cefepime by Vitek 2 (29.0%) and ertapenem by DD (9.1%); essential agreement less than 90% was identified with the following combinations: aztreonam by MicroScan (86.4%), aztreonam by Vitek 2 (88.9%), cefepime by Selux (86.3%), cefepime by Vitek 2 (76.8%), ceftazidime by Vitek 2 (89.9%), and levofloxacin by MicroScan (83.4%). For P. aeruginosa , essential agreement less than 90% was identified with the following combinations: gentamicin by Selux (87.2%), tobramycin by Selux (86.6%), and ciprofloxacin by Phoenix (88.4%). Overall, antimicrobials that had low demonstrable bias across all automated commercial AST systems included ampicillin, amoxicillin-clavulanate, ceftazidime-avibactam, ertapenem, and trimethoprim-sulfamethoxazole. Comparing commercial testing systems head-to-head against a reference standard provides insight into the strengths and weaknesses of the performance of these test systems, and these insights can subsequently inform local decisions regarding further investigations and potential operational mitigation strategies. IMPORTANCE: This study assessed and compared the performance of multiple commercial antimicrobial susceptibility testing (AST) systems and disk diffusion methods. The accuracy of determining minimum inhibitory concentrations or zone diameters of antimicrobials and the associated interpretive categories were studied for 372 isolates of Enterobacterales and Pseudomonas aeruginosa . Performance of the evaluated systems revealed that multiple antimicrobial-organism combinations were below the standards typically required by regulatory agencies and clinical laboratories. These deficiencies varied across the commercial platforms and disk diffusion methods, highlighting the importance of benchmarking studies that compare the performance using identical isolates. These identified performance weaknesses may warrant further study and/or the implementation of mitigation strategies in clinical laboratory operations to prevent the reporting of errant results.
- 14 October 2026
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 64 (10)
Open AccessBenchmarking four commercial antimicrobial susceptibility testing systems and disk diffusion to reference broth microdilution in the assessment of gram-negative bacterial isolates
Commercial antimicrobial susceptibility testing (AST) systems for gram-negative bacteria provide operational advantages over reference broth microdilution (BMD) testing, but the results produced by commercial AST systems might not be as accurate as the reference method. Assessing and comparing the performance of AST systems can be informative for clinical microbiology practice. In total, 280 clinical isolates and 100 isolates from the U.S. Centers for Disease Control and Prevention Antimicrobial Resistance Isolate Bank, including Enterobacterales and Pseudomonas aeruginosa, were intended to be tested using disk diffusion (DD) and automated commercial AST systems, such as Selux AST System (Selux Diagnostics), MicroScan (Beckman Coulter), Phoenix (Becton, Dickinson and Company), and Vitek 2 (bioMérieux). These results were compared to BMD as the reference standard. In total, 372 isolates were assessed. For Enterobacterales, the greatest frequency of very major errors was identified with cefepime by Vitek 2 (29.0%) and ertapenem by DD (9.1%); essential agreement less than 90% was identified with the following combinations: aztreonam by MicroScan (86.4%), aztreonam by Vitek 2 (88.9%), cefepime by Selux (86.3%), cefepime by Vitek 2 (76.8%), ceftazidime by Vitek 2 (89.9%), and levofloxacin by MicroScan (83.4%). For P. aeruginosa , essential agreement less than 90% was identified with the following combinations: gentamicin by Selux (87.2%), tobramycin by Selux (86.6%), and ciprofloxacin by Phoenix (88.4%). Overall, antimicrobials that had low demonstrable bias across all automated commercial AST systems included ampicillin, amoxicillin-clavulanate, ceftazidime-avibactam, ertapenem, and trimethoprim-sulfamethoxazole. Comparing commercial testing systems head-to-head against a reference standard provides insight into the strengths and weaknesses of the performance of these test systems, and these insights can subsequently inform local decisions regarding further investigations and potential operational mitigation strategies. IMPORTANCE: This study assessed and compared the performance of multiple commercial antimicrobial susceptibility testing (AST) systems and disk diffusion methods. The accuracy of determining minimum inhibitory concentrations or zone diameters of antimicrobials and the associated interpretive categories were studied for 372 isolates of Enterobacterales and Pseudomonas aeruginosa . Performance of the evaluated systems revealed that multiple antimicrobial-organism combinations were below the standards typically required by regulatory agencies and clinical laboratories. These deficiencies varied across the commercial platforms and disk diffusion methods, highlighting the importance of benchmarking studies that compare the performance using identical isolates. These identified performance weaknesses may warrant further study and/or the implementation of mitigation strategies in clinical laboratory operations to prevent the reporting of errant results.
- Open Access
- 14 May 2025
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 63 (5) , e0181924
Multi-center evaluation of the Selux next-generation phenotyping system for gram-negative direct-from-positive blood culture antimicrobial susceptibility testing
Accurate and rapid antimicrobial susceptibility test (AST) results from positive blood cultures are crucial for patient care and combatting antimicrobial resistance. Although recent advancements in rapid direct-from-positive blood culture (PBC) identification platforms have enabled the provision of species-level identification and some resistance marker information within hours after blood culture positivity, AST results required for clinical decision-making often require 48 h after blood culture positivity. This study evaluated the Selux next-generation phenotyping system, including an automated PBC Separator and the Selux AST system in a multicenter clinical trial for their ability to perform AST directly from PBCs for gram-negative bacilli. The PBC separator produces McFarland equivalent inocula from positive blood cultures within 1 h, facilitating direct processing on the Selux AST system. The study evaluated 162 fresh clinical PBC samples, 307 seeded clinical samples, and 87 seeded challenge samples across 4 sites for each of the 17 antimicrobials included in the panel. The results demonstrate that the Selux system’s clinical performance, reproducibility, and analytical performances are consistent when using positive blood cultures held for up to 16 h after positivity on the BACTEC and BacT/ALERT 3D and BacT/ALERT VIRTUO blood culture systems, including all major BACTEC and BacT/ALERT blood culture bottle types. These findings suggest that the PBC Separator with the Selux AST system is a valuable addition to the arsenal of tools available for rapid sepsis diagnosis and management. IMPORTANCE: Technologies that consistently and substantially shorten the time between blood bottle positivity, organism identification, and complete AST results are crucial for ensuring that antimicrobial therapy can be tailored. The Selux PBC Separator and the Selux AST system perform rapid AST directly from positive blood culture bottles. This substantially shortens the gap between obtaining a positive blood bottle and organism identification and the availability of a fully actionable AST result.
- 14 May 2025
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 63 (5) , e0181924
Open AccessMulti-center evaluation of the Selux next-generation phenotyping system for gram-negative direct-from-positive blood culture antimicrobial susceptibility testing
Accurate and rapid antimicrobial susceptibility test (AST) results from positive blood cultures are crucial for patient care and combatting antimicrobial resistance. Although recent advancements in rapid direct-from-positive blood culture (PBC) identification platforms have enabled the provision of species-level identification and some resistance marker information within hours after blood culture positivity, AST results required for clinical decision-making often require 48 h after blood culture positivity. This study evaluated the Selux next-generation phenotyping system, including an automated PBC Separator and the Selux AST system in a multicenter clinical trial for their ability to perform AST directly from PBCs for gram-negative bacilli. The PBC separator produces McFarland equivalent inocula from positive blood cultures within 1 h, facilitating direct processing on the Selux AST system. The study evaluated 162 fresh clinical PBC samples, 307 seeded clinical samples, and 87 seeded challenge samples across 4 sites for each of the 17 antimicrobials included in the panel. The results demonstrate that the Selux system’s clinical performance, reproducibility, and analytical performances are consistent when using positive blood cultures held for up to 16 h after positivity on the BACTEC and BacT/ALERT 3D and BacT/ALERT VIRTUO blood culture systems, including all major BACTEC and BacT/ALERT blood culture bottle types. These findings suggest that the PBC Separator with the Selux AST system is a valuable addition to the arsenal of tools available for rapid sepsis diagnosis and management. IMPORTANCE: Technologies that consistently and substantially shorten the time between blood bottle positivity, organism identification, and complete AST results are crucial for ensuring that antimicrobial therapy can be tailored. The Selux PBC Separator and the Selux AST system perform rapid AST directly from positive blood culture bottles. This substantially shortens the gap between obtaining a positive blood bottle and organism identification and the availability of a fully actionable AST result.
- Open Access
- 13 November 2024
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 62 (11) , e0064924
Evaluation of gradient strip diffusion for susceptibility testing of aztreonam–avibactam in metallo-β-lactamase-producing Enterobacterales
The emergence of metallo-β-lactamase (MBL)-producing Enterobacterales presents unique clinical treatment challenges. Recently developed β-lactam/ β-lactamase inhibitor combination agents, while effective against other carbapenemase-producing organisms, are notably ineffective against MBL producers. While MBLs do not hydrolyze monobactams (aztreonam), many MBL-producing organisms are resistant to aztreonam through alternate mechanisms, leaving cefiderocol as the sole monotherapy treatment option recommended for MBL producers. Recent guidelines for the treatment of MBL-harboring organisms have added combination therapy with aztreonam and ceftazidime–avibactam, using ceftazidime–avibactam as a source of the β-lactamase inhibitor avibactam. Current laboratory testing options for the combination of aztreonam–avibactam are limited to broth microdilution (BMD) and broth disk elution (BDE) methods, which are not practical in most clinical laboratories. In this study, we evaluated the performance of aztreonam/avibactam gradient strips on 103 MBL-producing Enterobacterales patient isolates as well as an additional 31 isolates from the CDC AR Bank. All MBL Enterobacterales patient isolates included in this study harbored a New Delhi metallo-β-lactamase ( bla NDM ) gene. Essential agreement of gradient strip minimal inhibitory concentrations (MICs) for patient isolates compared to BMD was 93.2%. While there are no established breakpoints for aztreonam–avibactam, category agreement (CA) for patient isolates was 97.1% when using the CLSI aztreonam breakpoints. There were no major or very major errors observed. There were three minor errors. Precision for aztreonam–avibactam gradient strip diffusion was 100%. These data demonstrate that the use of gradient strip diffusion for aztreonam–avibactam MIC determination in MBL-producing Enterobacterales is a viable option for clinical laboratories.
- 13 November 2024
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 62 (11) , e0064924
Open AccessEvaluation of gradient strip diffusion for susceptibility testing of aztreonam–avibactam in metallo-β-lactamase-producing Enterobacterales
The emergence of metallo-β-lactamase (MBL)-producing Enterobacterales presents unique clinical treatment challenges. Recently developed β-lactam/ β-lactamase inhibitor combination agents, while effective against other carbapenemase-producing organisms, are notably ineffective against MBL producers. While MBLs do not hydrolyze monobactams (aztreonam), many MBL-producing organisms are resistant to aztreonam through alternate mechanisms, leaving cefiderocol as the sole monotherapy treatment option recommended for MBL producers. Recent guidelines for the treatment of MBL-harboring organisms have added combination therapy with aztreonam and ceftazidime–avibactam, using ceftazidime–avibactam as a source of the β-lactamase inhibitor avibactam. Current laboratory testing options for the combination of aztreonam–avibactam are limited to broth microdilution (BMD) and broth disk elution (BDE) methods, which are not practical in most clinical laboratories. In this study, we evaluated the performance of aztreonam/avibactam gradient strips on 103 MBL-producing Enterobacterales patient isolates as well as an additional 31 isolates from the CDC AR Bank. All MBL Enterobacterales patient isolates included in this study harbored a New Delhi metallo-β-lactamase ( bla NDM ) gene. Essential agreement of gradient strip minimal inhibitory concentrations (MICs) for patient isolates compared to BMD was 93.2%. While there are no established breakpoints for aztreonam–avibactam, category agreement (CA) for patient isolates was 97.1% when using the CLSI aztreonam breakpoints. There were no major or very major errors observed. There were three minor errors. Precision for aztreonam–avibactam gradient strip diffusion was 100%. These data demonstrate that the use of gradient strip diffusion for aztreonam–avibactam MIC determination in MBL-producing Enterobacterales is a viable option for clinical laboratories.