Michelle W. L. Khoo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michelle W. L. Khoo has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Paul Lebel
Chan Zuckerberg Biohub San Francisco
5 shared publications - Rafael Gómez-Sjöberg
Chan Zuckerberg Biohub San Francisco
4 shared publications - Ilakkiyan Jeyakumar
Chan Zuckerberg Biohub San Francisco
3 shared publications - Aditi Saxena
Chan Zuckerberg Biohub San Francisco Department of Bioengineering 499 Illinois Street, San Francisco, CA 94158
2 shared publications - Austin J. Graham
Department of Pharmaceutical Chemistry, University of California San Francisco, San Francisco, USA
2 shared publications - Axel Jacobsen
Chan Zuckerberg Biohub San Francisco
2 shared publications
Latest Publications
- Open Access
Rapid Sepsis Diagnosis in Critically Ill Adults with Remoscope Label-Free Whole-Blood Imaging
Sepsis is life-threatening, yet diagnosis remains a major global challenge because existing approaches lack speed and accuracy. Here we show that label-free imaging cytometry of 10 µL whole-blood samples by Remoscope rapidly distinguishes patients with sepsis from those with non-infectious critical illness and healthy controls. In a prospective study of 29 critically ill adults, multi-physician adjudication identified sepsis ( n =13), non-infectious critical illness ( n =12), and indeterminate status ( n =4); these patients were compared to healthy controls ( n =22). A multiple instance learning (MIL) model pooled unbiased features from thousands of blood images per patient. Optimized for rule-out, the three-class model detected sepsis with 100% sensitivity and 85.3% specificity. Class activation heatmaps, unsupervised single cell embeddings, and morphometrics converged on abnormal leukocyte and erythrocyte morphology, including immature neutrophil-like cells. Label-free whole-blood imaging with MIL detects sepsis-associated hematologic signatures without stains or cold chain, establishing a foundation for rapid critical care diagnostics.
Open AccessRapid Sepsis Diagnosis in Critically Ill Adults with Remoscope Label-Free Whole-Blood Imaging
Sepsis is life-threatening, yet diagnosis remains a major global challenge because existing approaches lack speed and accuracy. Here we show that label-free imaging cytometry of 10 µL whole-blood samples by Remoscope rapidly distinguishes patients with sepsis from those with non-infectious critical illness and healthy controls. In a prospective study of 29 critically ill adults, multi-physician adjudication identified sepsis ( n =13), non-infectious critical illness ( n =12), and indeterminate status ( n =4); these patients were compared to healthy controls ( n =22). A multiple instance learning (MIL) model pooled unbiased features from thousands of blood images per patient. Optimized for rule-out, the three-class model detected sepsis with 100% sensitivity and 85.3% specificity. Class activation heatmaps, unsupervised single cell embeddings, and morphometrics converged on abnormal leukocyte and erythrocyte morphology, including immature neutrophil-like cells. Label-free whole-blood imaging with MIL detects sepsis-associated hematologic signatures without stains or cold chain, establishing a foundation for rapid critical care diagnostics.
- Top Cited PapersOpen Access
- 10 March 2026
- Published by Springer Nature in Nature Materials
- Vol. 25 (7) , 1239-1251
Stress-relaxing granular bioprinting materials enable complex and uniform organoid self-organization
Complex and robust tissue self-organization requires defined initial conditions and dynamic boundaries—neighbouring tissues and extracellular matrix that actively evolve to guide morphogenesis. A major challenge in tissue engineering is identifying material properties that are compatible with controlling initial culture conditions while mimicking dynamic tissue boundaries. Here we describe a highly tunable granular biomaterial, MAGIC matrix, that supports both long-term bioprinting and gold-standard tissue self-organization. We identify that significant stress relaxation at the long timescales and large deformation magnitudes relevant to self-organization is required for optimal morphogenesis. We apply optimized MAGIC matrices toward precise extrusion bioprinting of saturated cell suspensions directly into three-dimensional culture. Carefully controlling initial conditions for tissue growth yields dramatic increases in organoid reproducibility and complexity across multiple tissue types, enabling high-throughput generation of organoid arrays and perfusable three-dimensional microphysiological systems. Our results identify key biomaterial parameters for optimal organoid morphogenesis and lay the foundation for fabricating more complex and reproducible self-organized tissues.
- 10 March 2026
- Published by Springer Nature in Nature Materials
- Vol. 25 (7) , 1239-1251
Top Cited PapersOpen AccessStress-relaxing granular bioprinting materials enable complex and uniform organoid self-organization
Complex and robust tissue self-organization requires defined initial conditions and dynamic boundaries—neighbouring tissues and extracellular matrix that actively evolve to guide morphogenesis. A major challenge in tissue engineering is identifying material properties that are compatible with controlling initial culture conditions while mimicking dynamic tissue boundaries. Here we describe a highly tunable granular biomaterial, MAGIC matrix, that supports both long-term bioprinting and gold-standard tissue self-organization. We identify that significant stress relaxation at the long timescales and large deformation magnitudes relevant to self-organization is required for optimal morphogenesis. We apply optimized MAGIC matrices toward precise extrusion bioprinting of saturated cell suspensions directly into three-dimensional culture. Carefully controlling initial conditions for tissue growth yields dramatic increases in organoid reproducibility and complexity across multiple tissue types, enabling high-throughput generation of organoid arrays and perfusable three-dimensional microphysiological systems. Our results identify key biomaterial parameters for optimal organoid morphogenesis and lay the foundation for fabricating more complex and reproducible self-organized tissues.
- 9 July 2025
- Published by Oxford University Press (OUP) in Transactions of the Royal Society of Tropical Medicine and Hygiene
- Vol. 119 (9) , 1100-1111
Remoscope: a label-free imaging cytometer for malaria diagnostics
Background: Malaria diagnostic testing remains a burden on healthcare systems. Here we present Remoscope, a portable imaging cytometer that scans fresh, unstained whole blood using a custom neural network running on low-cost hardware. Remoscope performs label-free, quantitative, stage-specific detection of Plasmodium falciparum (Pf) by screening up to 2 million red blood cells (RBCs) in 1–12 min, without sample fixation, staining or slide scanning. Low-cost disposable cartridges are used to confine flowing blood to an ultrathin sheet for imaging. Methods: Performance was benchmarked in vitro by titration of cultured Pf (17.1–710 000 parasites/µl) into whole blood. A study of Remoscope's diagnostic accuracy was evaluated in a cohort of 500 individuals in eastern Uganda, comprising 601 unique clinic visits. Parallel measurements of parasitaemia were performed using Remoscope, quantitative polymerase chain reaction (qPCR) and thick blood smears. Results: Clinically, Remoscope's 10× diluted blood assay had a limit of detection with respect to qPCR of 95.1 parasites/µl, sensitivity of 83%, specificity of 96%, positive predictive value of 91% and negative predictive value of 93%. Conclusions: Remoscope's speed, accuracy, cost and ease of use address key challenges in malaria diagnosis worldwide. In this pilot study, the diagnostic accuracy approaches that of expert thick smears performed in duplication.
- 9 July 2025
- Published by Oxford University Press (OUP) in Transactions of the Royal Society of Tropical Medicine and Hygiene
- Vol. 119 (9) , 1100-1111
Remoscope: a label-free imaging cytometer for malaria diagnostics
Background: Malaria diagnostic testing remains a burden on healthcare systems. Here we present Remoscope, a portable imaging cytometer that scans fresh, unstained whole blood using a custom neural network running on low-cost hardware. Remoscope performs label-free, quantitative, stage-specific detection of Plasmodium falciparum (Pf) by screening up to 2 million red blood cells (RBCs) in 1–12 min, without sample fixation, staining or slide scanning. Low-cost disposable cartridges are used to confine flowing blood to an ultrathin sheet for imaging. Methods: Performance was benchmarked in vitro by titration of cultured Pf (17.1–710 000 parasites/µl) into whole blood. A study of Remoscope's diagnostic accuracy was evaluated in a cohort of 500 individuals in eastern Uganda, comprising 601 unique clinic visits. Parallel measurements of parasitaemia were performed using Remoscope, quantitative polymerase chain reaction (qPCR) and thick blood smears. Results: Clinically, Remoscope's 10× diluted blood assay had a limit of detection with respect to qPCR of 95.1 parasites/µl, sensitivity of 83%, specificity of 96%, positive predictive value of 91% and negative predictive value of 93%. Conclusions: Remoscope's speed, accuracy, cost and ease of use address key challenges in malaria diagnosis worldwide. In this pilot study, the diagnostic accuracy approaches that of expert thick smears performed in duplication.
- Open Access
Remoscope: a label-free imaging cytometer for malaria diagnostics
Malaria diagnostic testing in high transmission settings remains a burden on healthcare systems. Here we present Remoscope, a portable automated imaging cytometer that scans fresh, unstained whole blood using a custom neural network on low-cost hardware. By screening up to two million red blood cells, Remoscope performs label-free quantitative stage-specific detection of Plasmodium falciparum ( Pf ) in 1-12 minutes without sample fixation, staining, or slide scanning. Flow is used to achieve high cellular throughput, with blood confined to a 4.5 µm monolayer in low-cost disposable flow cartridges. Remoscope performance was benchmarked in vitro by titration of cultured parasites into uninfected whole blood at concentrations of 17.1-710,000 parasites/µL. Counts generated by Remoscope demonstrated a linear response across the entire range. Considering drug susceptibility assays, the half-maximal effective concentration (EC50) of chloroquine (CQ) for the W2 strain of Pf was 211 nM by Remoscope, compared to 191 nM for conventional flow cytometry. Remoscope’s real-world diagnostic accuracy was evaluated in a cohort of 500 individuals in eastern Uganda, comprising 601 unique clinic visits. Parallel measurements of parasitemia were performed using Remoscope, qPCR targeting the multicopy conserved var gene acidic terminal sequence, and microscopic evaluation of Giemsa-stained thick blood smears. Remoscope’s limit of detection with respect to qPCR was 95.1 parasites/µL. At this threshold, the system had a sensitivity of 83%, specificity of 96%, Positive Predictive Value (PPV) of 91%, and a Negative Predictive Value (NPV) of 93%. Remoscope’s speed, accuracy, low cost, and ease of use address practical challenges in malaria diagnostic settings around the world. As a general imaging flow cytometer, Remoscope may also inform the development of recognition models for the diagnosis of other infectious and noninfectious blood disorders.
Open AccessRemoscope: a label-free imaging cytometer for malaria diagnostics
Malaria diagnostic testing in high transmission settings remains a burden on healthcare systems. Here we present Remoscope, a portable automated imaging cytometer that scans fresh, unstained whole blood using a custom neural network on low-cost hardware. By screening up to two million red blood cells, Remoscope performs label-free quantitative stage-specific detection of Plasmodium falciparum ( Pf ) in 1-12 minutes without sample fixation, staining, or slide scanning. Flow is used to achieve high cellular throughput, with blood confined to a 4.5 µm monolayer in low-cost disposable flow cartridges. Remoscope performance was benchmarked in vitro by titration of cultured parasites into uninfected whole blood at concentrations of 17.1-710,000 parasites/µL. Counts generated by Remoscope demonstrated a linear response across the entire range. Considering drug susceptibility assays, the half-maximal effective concentration (EC50) of chloroquine (CQ) for the W2 strain of Pf was 211 nM by Remoscope, compared to 191 nM for conventional flow cytometry. Remoscope’s real-world diagnostic accuracy was evaluated in a cohort of 500 individuals in eastern Uganda, comprising 601 unique clinic visits. Parallel measurements of parasitemia were performed using Remoscope, qPCR targeting the multicopy conserved var gene acidic terminal sequence, and microscopic evaluation of Giemsa-stained thick blood smears. Remoscope’s limit of detection with respect to qPCR was 95.1 parasites/µL. At this threshold, the system had a sensitivity of 83%, specificity of 96%, Positive Predictive Value (PPV) of 91%, and a Negative Predictive Value (NPV) of 93%. Remoscope’s speed, accuracy, low cost, and ease of use address practical challenges in malaria diagnostic settings around the world. As a general imaging flow cytometer, Remoscope may also inform the development of recognition models for the diagnosis of other infectious and noninfectious blood disorders.
- Open Access
Stress relaxing granular bioprinting materials enable complex and uniform organoid self-organization
Complex and robust self-organization requires defined initial conditions and dynamic boundaries – neighboring tissues and extracellular matrix (ECM) that actively evolve to guide morphogenesis. A major challenge in tissue engineering is identifying material properties that mimic dynamic tissue boundaries but that are compatible with the engineering tools necessary for controlling the initial conditions of culture. Here we describe a highly tunable granular biomaterial, MAGIC matrix, that supports long-term bioprinting and gold-standard tissue self-organization. MAGIC matrix is designed for two temperature regimes: at 4 °C it exhibits reversible yield-stress behavior to support hours-long high-fidelity 3D printing without compromising cell viability; when transferred to cell culture at 37 °C, the material cross-links and exhibits viscoelasticity and stress relaxation that can be tuned to match numerous conditions, including that of reconstituted basement membrane matrices like Matrigel. We demonstrate that the timescale of stress relaxation and loss tangent are decoupled in MAGIC matrices, allowing us to test the role of stress relaxation rate and strain-dependence across formulations with identical storage and loss moduli. We find that fast absolute stress relaxation rates and large relative deformation magnitudes are required to optimize for morphogenesis. We apply optimized MAGIC matrices toward precise extrusion bioprinting of saturated cell suspensions directly into 3D culture. The ability to carefully control initial conditions for tissue growth yields dramatic increases in organoid reproducibility and complexity across multiple tissue types. We also fabricate perfusable 3D microphysiological systems that experience large strains in response to pressurization due to the compliant and dynamic tissue boundaries. Combined, our results both identify key parameters for optimal organoid morphogenesis in an engineered material and lay the foundation for fabricating more complex and reproducible tissue morphologies by canalizing their self-organization in both space and time.
Open AccessStress relaxing granular bioprinting materials enable complex and uniform organoid self-organization
Complex and robust self-organization requires defined initial conditions and dynamic boundaries – neighboring tissues and extracellular matrix (ECM) that actively evolve to guide morphogenesis. A major challenge in tissue engineering is identifying material properties that mimic dynamic tissue boundaries but that are compatible with the engineering tools necessary for controlling the initial conditions of culture. Here we describe a highly tunable granular biomaterial, MAGIC matrix, that supports long-term bioprinting and gold-standard tissue self-organization. MAGIC matrix is designed for two temperature regimes: at 4 °C it exhibits reversible yield-stress behavior to support hours-long high-fidelity 3D printing without compromising cell viability; when transferred to cell culture at 37 °C, the material cross-links and exhibits viscoelasticity and stress relaxation that can be tuned to match numerous conditions, including that of reconstituted basement membrane matrices like Matrigel. We demonstrate that the timescale of stress relaxation and loss tangent are decoupled in MAGIC matrices, allowing us to test the role of stress relaxation rate and strain-dependence across formulations with identical storage and loss moduli. We find that fast absolute stress relaxation rates and large relative deformation magnitudes are required to optimize for morphogenesis. We apply optimized MAGIC matrices toward precise extrusion bioprinting of saturated cell suspensions directly into 3D culture. The ability to carefully control initial conditions for tissue growth yields dramatic increases in organoid reproducibility and complexity across multiple tissue types. We also fabricate perfusable 3D microphysiological systems that experience large strains in response to pressurization due to the compliant and dynamic tissue boundaries. Combined, our results both identify key parameters for optimal organoid morphogenesis in an engineered material and lay the foundation for fabricating more complex and reproducible tissue morphologies by canalizing their self-organization in both space and time.