YAYann Anquetin
Yann Anquetin
*This is an algorithmically generated author record based on publicly available information.
Research Subjects
Research Interests
Yann Anquetin has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Alex Grosjean
University of Tennessee, Knoxville, TN 37996, United States of America
1 shared publication C. Pocheau
1 shared publication- David Moiraf
CEA, IRFM, F-13108 Saint-Paul-lez-Durance, France
1 shared publication Davide Traversari
CEA, IRFM, F-13108 Saint-Paul-lez-Durance, France
1 shared publicationG. Laffont
1 shared publication- Guido Ciraolo
IRFM
1 shared publication
Latest Publications
- Open Access
- 12 March 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (5)
Power sharing in WEST double-null plasmas
This study investigates L-mode power sharing between divertor target plates in Double-Null (DN) magnetic configuration on the WEST tokamak. A series of discharges scanning the distance between the separatrices at the outer mid-plane ($\delta R_{sep}$) were analyzed using Langmuir probes, embedded fiber Bragg gratings, and calorimetry to characterize heat flux profiles and total deposited power in attached regime. Results show that DN configurations could significantly reduce the peak heat flux measured by fiber Bragg gratings on the lower divertor by over 70\% compared to LSN as power is more evenly distributed between upper and lower divertors. However, the heat flux is shown to be highly sensitive (peak value multiplied by 2) to millimetric variations of the $\delta R_{sep}$. These findings reinforce the DN configuration's potential for mitigating peak heat loads in next step fusion devices, while highlighting the need for precise magnetic control in attached regime. Power deposition remains asymmetric in connected DN, with up to 89\% of power directed to outer targets and 68\% to the lower divertor, consistent with the ballooned nature of radial transport at the low-field side and downward $\pmb{B} \times \pmb{\nabla} B$ drift effects. To quantify these effects, we develop a revised power sharing model building on Brunner’s formulation, incorporating localized sources at the inner ($S_i$) and outer ($S_o$) mid-plane, a vertical drift bias $b$, and a cooling factor $\kappa_{\text{diss}}$. The best-fit parameters suggest that approximately 58\% of the exhaust power preferentially flows downward due to vertical drifts, and that a secondary inner mid-plane source contributes up to 13\% of the total power in WEST. The decay lengths obtained from the fit are in agreement with those independently measured from heat flux profiles, further validating the model.- 12 March 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (5)
Open AccessPower sharing in WEST double-null plasmas
This study investigates L-mode power sharing between divertor target plates in Double-Null (DN) magnetic configuration on the WEST tokamak. A series of discharges scanning the distance between the separatrices at the outer mid-plane ($\delta R_{sep}$) were analyzed using Langmuir probes, embedded fiber Bragg gratings, and calorimetry to characterize heat flux profiles and total deposited power in attached regime. Results show that DN configurations could significantly reduce the peak heat flux measured by fiber Bragg gratings on the lower divertor by over 70\% compared to LSN as power is more evenly distributed between upper and lower divertors. However, the heat flux is shown to be highly sensitive (peak value multiplied by 2) to millimetric variations of the $\delta R_{sep}$. These findings reinforce the DN configuration's potential for mitigating peak heat loads in next step fusion devices, while highlighting the need for precise magnetic control in attached regime. Power deposition remains asymmetric in connected DN, with up to 89\% of power directed to outer targets and 68\% to the lower divertor, consistent with the ballooned nature of radial transport at the low-field side and downward $\pmb{B} \times \pmb{\nabla} B$ drift effects. To quantify these effects, we develop a revised power sharing model building on Brunner’s formulation, incorporating localized sources at the inner ($S_i$) and outer ($S_o$) mid-plane, a vertical drift bias $b$, and a cooling factor $\kappa_{\text{diss}}$. The best-fit parameters suggest that approximately 58\% of the exhaust power preferentially flows downward due to vertical drifts, and that a secondary inner mid-plane source contributes up to 13\% of the total power in WEST. The decay lengths obtained from the fit are in agreement with those independently measured from heat flux profiles, further validating the model. - 8 February 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 190
Surface heat flux estimation with embedded thermocouples and Fiber Bragg Grating sensor in ITER-like plasma facing components
- 8 February 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 190
Surface heat flux estimation with embedded thermocouples and Fiber Bragg Grating sensor in ITER-like plasma facing components