Haofeng Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haofeng Liu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Liang Qin
School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
2 shared publications - Changwen Zhang
School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
1 shared publication - Jing Wang
School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
1 shared publication - Kaipei Liu
Department of Electrical Engineering and Automation, Wuhan University, Wuhan, China
1 shared publication - Min He
Department of Electronic and Electrical Engineering, Wuhan Textile University, Wuhan, China
1 shared publication - Sihan Zhou
School of Electrical Engineering and Automation, Wuhan University, China
1 shared publication
Latest Publications
- 8 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 23 (15455955) , 10883-10898
Confusion False Data Injection Attacks and Novel Load Redistribution Schedule Under Line Parameters Fluctuations in Power Systems
Real-time parameter estimation captures the timevarying behavior of line parameters, preventing attackers from maintaining an accurate system model. As attackers rely on outdated parameter information, the measurement effects of their injections no longer align with the attacker’s intended outcomes, rendering perfectly stealthy False Data Injection Attacks (FDIAs) ineffective. This paper introduces Confusion False Data Injection Attacks (CFDIAs), which exploit the mismatch between an attacker’s outdated model and the system’s time-varying reality. CFDIAs reshape the resulting measurement discrepancies so they fall within the statistical behavior of normal noise, enabling approximate stealthiness under residual-based detection. A bi-level optimization framework is established to quantify the economic impacts of CFDIAs. The upper level designs approximately stealthy attacks, while the lower level performs optimal power flow. A Conservative Chance-Constraint Linearization (CCCL) technique is incorporated to provide a geometric and tractable approximation of nonlinear chance constraints. The results show that real-time parameter updates can create a false sense of protection, as some lines that appear secure remain covertly exploitable by CFDIAs. Experiments further demonstrate that such attacks can raise dispatch costs by 33.16% in the IEEE 30-bus system and 27.21% in the 89-bus system.
- 8 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 23 (15455955) , 10883-10898
Confusion False Data Injection Attacks and Novel Load Redistribution Schedule Under Line Parameters Fluctuations in Power Systems
Real-time parameter estimation captures the timevarying behavior of line parameters, preventing attackers from maintaining an accurate system model. As attackers rely on outdated parameter information, the measurement effects of their injections no longer align with the attacker’s intended outcomes, rendering perfectly stealthy False Data Injection Attacks (FDIAs) ineffective. This paper introduces Confusion False Data Injection Attacks (CFDIAs), which exploit the mismatch between an attacker’s outdated model and the system’s time-varying reality. CFDIAs reshape the resulting measurement discrepancies so they fall within the statistical behavior of normal noise, enabling approximate stealthiness under residual-based detection. A bi-level optimization framework is established to quantify the economic impacts of CFDIAs. The upper level designs approximately stealthy attacks, while the lower level performs optimal power flow. A Conservative Chance-Constraint Linearization (CCCL) technique is incorporated to provide a geometric and tractable approximation of nonlinear chance constraints. The results show that real-time parameter updates can create a false sense of protection, as some lines that appear secure remain covertly exploitable by CFDIAs. Experiments further demonstrate that such attacks can raise dispatch costs by 33.16% in the IEEE 30-bus system and 27.21% in the 89-bus system.
- Open Access
- 7 August 2024
- Published by Association for Computing Machinery (ACM)
- p. 117-122
A Novel Fault Diagnosis Method for Main Circulation Pump of VSC-HVDC Valve Cooling System Based on CWT and Dilated 2DCNN
Main circulation pumps play a vital role in VSC-HVDC systems cooling process. Current solutions for unattended operation and maintenance of these pumps are underdeveloped, and fault diagnosis research is limited. To address this issue, this paper presents a fault diagnosis model for the main circulation pump of a VSC-HVDC cooling system using continuous wavelet transform (CWT) and dilated 2D convolutional neural networks (2DCNN). CWT converts one-dimensional time-series vibration data into two-dimensional time-frequency images, which retain both time-domain and frequency-domain information and are processed by a dilated 2DCNN to enhance fault detection accuracy. Experiments demonstrate that the proposed method achieves higher evaluation metrics compared to other methods, with an accuracy of 95.20%, precision of 95.22%, recall of 95.20%, and F1 score of 95.20%, providing a data-driven fault diagnosis tool for on-site operation, maintenance, and planned repairs of the main circulation pump.
- 7 August 2024
- Published by Association for Computing Machinery (ACM)
- p. 117-122
Open AccessA Novel Fault Diagnosis Method for Main Circulation Pump of VSC-HVDC Valve Cooling System Based on CWT and Dilated 2DCNN
Main circulation pumps play a vital role in VSC-HVDC systems cooling process. Current solutions for unattended operation and maintenance of these pumps are underdeveloped, and fault diagnosis research is limited. To address this issue, this paper presents a fault diagnosis model for the main circulation pump of a VSC-HVDC cooling system using continuous wavelet transform (CWT) and dilated 2D convolutional neural networks (2DCNN). CWT converts one-dimensional time-series vibration data into two-dimensional time-frequency images, which retain both time-domain and frequency-domain information and are processed by a dilated 2DCNN to enhance fault detection accuracy. Experiments demonstrate that the proposed method achieves higher evaluation metrics compared to other methods, with an accuracy of 95.20%, precision of 95.22%, recall of 95.20%, and F1 score of 95.20%, providing a data-driven fault diagnosis tool for on-site operation, maintenance, and planned repairs of the main circulation pump.