Changwen Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Changwen Zhang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jing Wang
School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
2 shared publications - Kaipei Liu
Department of Electrical Engineering and Automation, Wuhan University, Wuhan, China
2 shared publications - Liang Qin
School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
2 shared publications - Xiaohong Ran
Department of Electrical and Electronic Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong
2 shared publications Haofeng Liu
School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
1 shared publication- Haofeng Liu
School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
1 shared publication
Latest Publications
- 8 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 23 (15455955) , 10883-10898
Confusion False Data Injection Attacks and Novel Load Redistribution Schedule Under Line Parameters Fluctuations in Power Systems
Real-time parameter estimation captures the timevarying behavior of line parameters, preventing attackers from maintaining an accurate system model. As attackers rely on outdated parameter information, the measurement effects of their injections no longer align with the attacker’s intended outcomes, rendering perfectly stealthy False Data Injection Attacks (FDIAs) ineffective. This paper introduces Confusion False Data Injection Attacks (CFDIAs), which exploit the mismatch between an attacker’s outdated model and the system’s time-varying reality. CFDIAs reshape the resulting measurement discrepancies so they fall within the statistical behavior of normal noise, enabling approximate stealthiness under residual-based detection. A bi-level optimization framework is established to quantify the economic impacts of CFDIAs. The upper level designs approximately stealthy attacks, while the lower level performs optimal power flow. A Conservative Chance-Constraint Linearization (CCCL) technique is incorporated to provide a geometric and tractable approximation of nonlinear chance constraints. The results show that real-time parameter updates can create a false sense of protection, as some lines that appear secure remain covertly exploitable by CFDIAs. Experiments further demonstrate that such attacks can raise dispatch costs by 33.16% in the IEEE 30-bus system and 27.21% in the 89-bus system.
- 8 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 23 (15455955) , 10883-10898
Confusion False Data Injection Attacks and Novel Load Redistribution Schedule Under Line Parameters Fluctuations in Power Systems
Real-time parameter estimation captures the timevarying behavior of line parameters, preventing attackers from maintaining an accurate system model. As attackers rely on outdated parameter information, the measurement effects of their injections no longer align with the attacker’s intended outcomes, rendering perfectly stealthy False Data Injection Attacks (FDIAs) ineffective. This paper introduces Confusion False Data Injection Attacks (CFDIAs), which exploit the mismatch between an attacker’s outdated model and the system’s time-varying reality. CFDIAs reshape the resulting measurement discrepancies so they fall within the statistical behavior of normal noise, enabling approximate stealthiness under residual-based detection. A bi-level optimization framework is established to quantify the economic impacts of CFDIAs. The upper level designs approximately stealthy attacks, while the lower level performs optimal power flow. A Conservative Chance-Constraint Linearization (CCCL) technique is incorporated to provide a geometric and tractable approximation of nonlinear chance constraints. The results show that real-time parameter updates can create a false sense of protection, as some lines that appear secure remain covertly exploitable by CFDIAs. Experiments further demonstrate that such attacks can raise dispatch costs by 33.16% in the IEEE 30-bus system and 27.21% in the 89-bus system.
- 7 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 3600-3608
Resilient Planning of Reactive Power Compensation in Active Distribution Networks: A Tri-Level Optimization Framework Against PLRAs
Load Redistribution Attacks (LRAs) threaten the secure operation of power distribution networks by manipulating load distribution. This paper proposes a stealthy attack called Partition Load Redistribution Attacks (PLRAs). Instead of causing detectable power transfers like traditional LRAs, PLRAs exploit the inherent reactive power balance within a network partition. This allows PLRAs to remain undetected. To mitigate the adverse impacts of PLRAs, a tri-level defense optimization framework is proposed, using Static Var Generators (SVGs) to enhance the resilience of the system against attacks. The upper level minimizes the investment cost of SVGs. The middle level simulates worst-case PLRAs, where an attacker manipulates reactive power to maximize operating costs and voltage deviations. The lower level models the optimal post-attack response of the operator using installed SVGs. A nested column-and-constraint generation (NCCG) algorithm is employed to solve the complex tri-level problem. The effectiveness of the proposed framework is validated through case studies on the IEEE 33-bus and 69-bus systems.
- 7 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 3600-3608
Resilient Planning of Reactive Power Compensation in Active Distribution Networks: A Tri-Level Optimization Framework Against PLRAs
Load Redistribution Attacks (LRAs) threaten the secure operation of power distribution networks by manipulating load distribution. This paper proposes a stealthy attack called Partition Load Redistribution Attacks (PLRAs). Instead of causing detectable power transfers like traditional LRAs, PLRAs exploit the inherent reactive power balance within a network partition. This allows PLRAs to remain undetected. To mitigate the adverse impacts of PLRAs, a tri-level defense optimization framework is proposed, using Static Var Generators (SVGs) to enhance the resilience of the system against attacks. The upper level minimizes the investment cost of SVGs. The middle level simulates worst-case PLRAs, where an attacker manipulates reactive power to maximize operating costs and voltage deviations. The lower level models the optimal post-attack response of the operator using installed SVGs. A nested column-and-constraint generation (NCCG) algorithm is employed to solve the complex tri-level problem. The effectiveness of the proposed framework is validated through case studies on the IEEE 33-bus and 69-bus systems.