MBMarcella Guedes Pereira Gouvêa Bezerra

Marcella Guedes Pereira Gouvêa Bezerra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marcella Guedes Pereira Gouvêa Bezerra has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Influence of build angle, printing layer thickness and aging on the flexural strength, precision, roughness and porosity analysis of a printed resin for provisional restorations

    by Fernanda Gurgel de Gois Moreira, Marcella Guedes Pereira Gouvêa Bezerra, Larissa Mendonça de Miranda, Sarah Emille Gomes da Silva, Eugênia Livia de Andrade Dantas, Frederico Barbosa de Sousa, Mutlu Özcan, Rodrigo Othávio de Assunção E Souza

    Evaluate the impact of printing parameters on flexural strength (σ), flexural modulus (E), precision, and surface topography characteristics of a resin used to produce provisional restorations. 450 bars for provisional restorations were printed using the SLA printing (25 × 2x2mm ISO-4049), and randomly divided into 30 groups (n = 15) according to the following factors: “printing layer thickness” (25 μm;50 μm;100 μm), “Build angle” (0°,30°,45°,60°,90°) and “thermocycling-TC” (with or without). Following printing, the samples underwent cleaning with isopropyl alcohol. Photopolymerization was performed for 15 min with an UV lamp. Subsequently, each bar was assessed using a digital caliper at 11 specific points in three dimensions for comparison with the STL file area for precision analysis. Half of the samples underwent thermocycling. All samples were submitted to the σ test. Data for σ (MPa), and (GPa) and precision (mm) were analyzed using 3 and 2-way ANOVA, respectively, and Tukey’s post hoc test (5%). Micro-CT, 3D profilometry, and SEM were also performed and analyzed descriptively. The 90°/25μmTC (63.0 ± 4.5) showed the highest σ, being only statistically similar to the 45°/25μmTC (57.7 ± 3.1). For precision 0°/25 μm (–2.56 ± 0.04) expressed the greatest variation to the other experimental groups with a sample shrinkage of 25.6% compared to the STL file. The profilometry revealed that the 30º/25 μm group showed prominent peaks and valleys, presenting elevated roughness values with an average of Sa (28.25 μm). Moreover, it was observed that the groups with a 60° angle presented the lowest porosity values. A print layer thickness of 25 μm combined with a build angle of 90º and 45º resulted in higher σ and greater precision.


  • Influence of 3D printing system, postpolymerization and aging protocols on resin flexural strength and dimensional stability for printing occlusal splints, models and temporary restorations

    by Fernanda Gurgel de Gois Moreira, Nathalia Ramos da Silva, Marcella Guedes Pereira Gouvêa Bezerra, Sarah Emille Gomes da Silva, Sheila Butler, Karina Barbosa Souza, Rodrigo Othávio de Assunção e Souza

    Objectives Investigate the effect of different postpolymerization protocols, aging, and 3D printing systems on the flexural strength (σ), dimensional stability, and roughness of resins used to fabricate occlusal splints, dental models, and temporary restorations. Material and methods 180 bars (25 × 2 x 2 mm—ISO 4049) of each type of resin (T—Temporary/Cosmos Temp, Yller; OS—Occlusal splint/Cosmos Splint, Yller; MO – Models/ Cosmos Model, Yller) were printed and divided into 12 groups (n = 15) according to the factors: “Postpolymerization” (Ctr – Control; UV – Ultraviolet oven and MW – Microwave); “Printer” (SLA- stereolithography (Forms 2/Formslab); LCD- liquid crystal display (FlashForge Foto 6.0/FlashForge)) and “Aging” (TC – 10,000 thermocycling cycles and Without). Each bar was measured with a digital caliper at 11 points before and after postpolymerization to evaluate dimensional stability. The samples were subjected to the σ test (100Kgf;1 mm/min). Data was evaluated using Three- and Two-way ANOVA, and Tukey’s test (5%). Weibull analysis, Scanning Electron Microscopic and optical profilometry was performed. Results LCD printing system and UV oven postpolymerization exhibited the highest σ (P < .05). The groups printed in SLA and post-polymerized in microwave ovens showed the greatest variations in their dimensions, for the occlusal splint resin, the OS-SLA-MW group (-4.29 ± 3.15)A showed a shrinkage of 40.2%. The resins for models (3.31 ± 0.66)A and temporary (-2.06 ± 1.52)A showed a shrinkage of 33% and 20.6%, respectively. Conclusions LCD printing with UV light postpolymerization was the most effective method for resins used in occlusal splints, dental models, and temporary restorations. SLA printing with UV postpolymerization showed the most significant dimensional changes, leading to shrinkage in occlusal splint resins, while model resins and temporary restorations expanded. Clinical relevance Resins for 3D printing should ideally be post-polymerized with UV light and printed using LCD technology, as this approach results in better mechanical properties and less dimensional change compared to microwave oven post-polymerization.