Si Zhong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Si Zhong has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Guochun Huang
School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, China
1 shared publication - Luye Liang
School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, Guangxi, China
1 shared publication - Songchun Li
School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, China
1 shared publication - Wenlong Lv
School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, Guangxi, China
1 shared publication - Yanli Bai
School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, Guangxi, China
1 shared publication - Yi Jiang
School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, China
1 shared publication
Latest Publications
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-7
Reduction of Dynamic Spatial Distortion of Miniaturized Streak Tube Using Deflection Compensation Technique
In miniaturized streak tube (MST), the scanning electric field, while deflecting dynamic imaging, inevitably causes dynamic spatial distortion (DSD), declining dynamic spatial resolution (DSR) uniformity and hindering large-area applications. To mitigate these cases, a compensation system has been devised, aiming to reduce DSD and enhance DSR uniformity by the application of the falling edge of V-shaped high-voltage pulse (VHVP). The research results demonstrate that the VHVP, featuring a rising edge slope of 12.68 kV/ns and a falling edge slope of 15.22 kV/ns, which successfully generated by the Marx circuit combined with the LC filter. When the VHVP, in conjunction with the deflection compensation technique (DCT), was implemented in the MST, a notable reduction in DSD was achieved. Specifically, within a Φ30-mm detection area, the DSD ratio has been decreased from 35.61% to 12.09%, accompanied by 5.45% improvement in DSR uniformity at 15-mm off-axis. Furthermore, comparative analysis revealed that compared to a MST with Φ16-mm detection area, which utilized a curved cathode and spherical phosphor screen to achieve 2.31% improvement ratio, the proposed DCT demonstrated significant 17.36% improvement ratio at an 8-mm off-axis point. These findings present a universal and effective approach for the technical enhancement of MST performance.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-7
Reduction of Dynamic Spatial Distortion of Miniaturized Streak Tube Using Deflection Compensation Technique
In miniaturized streak tube (MST), the scanning electric field, while deflecting dynamic imaging, inevitably causes dynamic spatial distortion (DSD), declining dynamic spatial resolution (DSR) uniformity and hindering large-area applications. To mitigate these cases, a compensation system has been devised, aiming to reduce DSD and enhance DSR uniformity by the application of the falling edge of V-shaped high-voltage pulse (VHVP). The research results demonstrate that the VHVP, featuring a rising edge slope of 12.68 kV/ns and a falling edge slope of 15.22 kV/ns, which successfully generated by the Marx circuit combined with the LC filter. When the VHVP, in conjunction with the deflection compensation technique (DCT), was implemented in the MST, a notable reduction in DSD was achieved. Specifically, within a Φ30-mm detection area, the DSD ratio has been decreased from 35.61% to 12.09%, accompanied by 5.45% improvement in DSR uniformity at 15-mm off-axis. Furthermore, comparative analysis revealed that compared to a MST with Φ16-mm detection area, which utilized a curved cathode and spherical phosphor screen to achieve 2.31% improvement ratio, the proposed DCT demonstrated significant 17.36% improvement ratio at an 8-mm off-axis point. These findings present a universal and effective approach for the technical enhancement of MST performance.