Xiaofei Cui
Xiaofei Cui has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chongbin Liu
Institute of Technological Sciences, Wuhan University, Wuhan, China
1 shared publication - Guoqiang Wu
School of Integrated Circuits, Wuhan University, Wuhan, China
1 shared publication - Hanzhe Liu
School of Information Science and Engineering, Shandong University, Qingdao, China
1 shared publication - Hui Zhao
China National Petroleum Corporation (CNPC) Natural Gas Sales Shandong Branch, Jinan, China
1 shared publication - Jianke Feng
Qingdao Qiancheng Technology Company Ltd., Qingdao, China
1 shared publication - Jifang Tao
School of Information Science and Engineering, Shandong University, Qingdao 266237, China
1 shared publication
Latest Publications
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
A High-Accuracy Ultrasonic Gas Flowmeter Based on Scandium-Doped Aluminum Nitride Piezoelectric Micromachined Ultrasonic Transducers
This paper presents an ultrasonic gas meter based on a scandium-doped aluminum nitride (Sc 0.2 Al 0.8 N) piezoelectric micromachined ultrasonic transducer (PMUT) array, where the characteristic dimension of each PMUT cell is only 600 μ m . The ultrasonic time of flight (TOF) difference method is employed to measure the gas flow rate, followed by ultrasonic signal processing and subsequent velocity profile and temperature compensation performed by the microcontroller. The cross correlation method is employed to detect the ultrasonic TOF difference and further suppress noise. In order to conduct a feasibility evaluation of the designed ultrasonic gas meter, the PMUT array, system control circuit and ultrasonic flow channel are combined and encapsulated in a meter case. Results indicate that the ultrasonic gas meter exhibits outstanding accuracy, repeatability and temperature adaptability. In the flow range of 0.025 m 3 /h to 2.8 m 3 /h, the minimum mean error and minimum repeatability error are 0.11% and 0.13%, respectively. Even when the temperature reaches 323.15 K, the designed device can achieve a mean error of no more than 0.41% with temperature compensation, which is comparable to commercialized ultrasonic gas meters. The highly reliable ultrasonic gas meter presented in this paper will provide a feasible solution for advancing portable devices.
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
A High-Accuracy Ultrasonic Gas Flowmeter Based on Scandium-Doped Aluminum Nitride Piezoelectric Micromachined Ultrasonic Transducers
This paper presents an ultrasonic gas meter based on a scandium-doped aluminum nitride (Sc 0.2 Al 0.8 N) piezoelectric micromachined ultrasonic transducer (PMUT) array, where the characteristic dimension of each PMUT cell is only 600 μ m . The ultrasonic time of flight (TOF) difference method is employed to measure the gas flow rate, followed by ultrasonic signal processing and subsequent velocity profile and temperature compensation performed by the microcontroller. The cross correlation method is employed to detect the ultrasonic TOF difference and further suppress noise. In order to conduct a feasibility evaluation of the designed ultrasonic gas meter, the PMUT array, system control circuit and ultrasonic flow channel are combined and encapsulated in a meter case. Results indicate that the ultrasonic gas meter exhibits outstanding accuracy, repeatability and temperature adaptability. In the flow range of 0.025 m 3 /h to 2.8 m 3 /h, the minimum mean error and minimum repeatability error are 0.11% and 0.13%, respectively. Even when the temperature reaches 323.15 K, the designed device can achieve a mean error of no more than 0.41% with temperature compensation, which is comparable to commercialized ultrasonic gas meters. The highly reliable ultrasonic gas meter presented in this paper will provide a feasible solution for advancing portable devices.