Hanzhe Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hanzhe Liu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Jifang Tao
School of Information Science and Engineering, Shandong University, Qingdao 266237, China
4 shared publications - Yuzhe Lin
College of Electronics and Information, Qingdao University, Qingdao, China
3 shared publications - Jinghua Lin
School of Information Science and Engineering, Shandong University, Qingdao, China
2 shared publications - Wei Tian
School of Information Science and Engineering, Shandong University, Qingdao, China
2 shared publications - Chongbin Liu
Institute of Technological Sciences, Wuhan University, Wuhan, China
1 shared publication Guoqiang Wu
Wuhan Univ, Inst Technol Sci, Wuhan 430072, Peoples R China
1 shared publication
Latest Publications
- 21 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-12
Hybrid Modeling and Experimental Validation for Gas Factor Determination in a MEMS Thermal Flow Meter
Undetermined gas factors of micro-electro-mechanical systems (MEMS) thermal mass flow meters (MFMs) constitute a critical bottleneck limiting their industrial adoption, particularly in semiconductor manufacturing. This limitation stems from current manufacturing practices, where only N2-calibrated products are mass-produced, whereas real-world applications require gas factor switching for multigas measurement. To address this challenge, this work presents a porous silicon-based MEMS thermal MFM and proposes a corresponding gas factor determination method using a hybrid modeling-experimental approach. The implementation involves: derivation of mathematical correlations among the output signal, gas flow rate, and thermophysical parameters via constitutive modeling, followed by empirical correction of model exponents using experimental datasets. The gas factors derived from this relationship were empirically validated using six test gases under constant ambient conditions. The results demonstrate high effectiveness, with all observed absolute errors confined within 6.4%FS, and exhibit excellent consistency. This work provides a practical methodology for gas factor determination in MEMS thermal MFMs, addressing a major limitation that restricts their universality in multigas measurement.
- 21 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-12
Hybrid Modeling and Experimental Validation for Gas Factor Determination in a MEMS Thermal Flow Meter
Undetermined gas factors of micro-electro-mechanical systems (MEMS) thermal mass flow meters (MFMs) constitute a critical bottleneck limiting their industrial adoption, particularly in semiconductor manufacturing. This limitation stems from current manufacturing practices, where only N2-calibrated products are mass-produced, whereas real-world applications require gas factor switching for multigas measurement. To address this challenge, this work presents a porous silicon-based MEMS thermal MFM and proposes a corresponding gas factor determination method using a hybrid modeling-experimental approach. The implementation involves: derivation of mathematical correlations among the output signal, gas flow rate, and thermophysical parameters via constitutive modeling, followed by empirical correction of model exponents using experimental datasets. The gas factors derived from this relationship were empirically validated using six test gases under constant ambient conditions. The results demonstrate high effectiveness, with all observed absolute errors confined within 6.4%FS, and exhibit excellent consistency. This work provides a practical methodology for gas factor determination in MEMS thermal MFMs, addressing a major limitation that restricts their universality in multigas measurement.
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
A High-Accuracy Ultrasonic Gas Flowmeter Based on Scandium-Doped Aluminum Nitride Piezoelectric Micromachined Ultrasonic Transducers
This paper presents an ultrasonic gas meter based on a scandium-doped aluminum nitride (Sc 0.2 Al 0.8 N) piezoelectric micromachined ultrasonic transducer (PMUT) array, where the characteristic dimension of each PMUT cell is only 600 μ m . The ultrasonic time of flight (TOF) difference method is employed to measure the gas flow rate, followed by ultrasonic signal processing and subsequent velocity profile and temperature compensation performed by the microcontroller. The cross correlation method is employed to detect the ultrasonic TOF difference and further suppress noise. In order to conduct a feasibility evaluation of the designed ultrasonic gas meter, the PMUT array, system control circuit and ultrasonic flow channel are combined and encapsulated in a meter case. Results indicate that the ultrasonic gas meter exhibits outstanding accuracy, repeatability and temperature adaptability. In the flow range of 0.025 m 3 /h to 2.8 m 3 /h, the minimum mean error and minimum repeatability error are 0.11% and 0.13%, respectively. Even when the temperature reaches 323.15 K, the designed device can achieve a mean error of no more than 0.41% with temperature compensation, which is comparable to commercialized ultrasonic gas meters. The highly reliable ultrasonic gas meter presented in this paper will provide a feasible solution for advancing portable devices.
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
A High-Accuracy Ultrasonic Gas Flowmeter Based on Scandium-Doped Aluminum Nitride Piezoelectric Micromachined Ultrasonic Transducers
This paper presents an ultrasonic gas meter based on a scandium-doped aluminum nitride (Sc 0.2 Al 0.8 N) piezoelectric micromachined ultrasonic transducer (PMUT) array, where the characteristic dimension of each PMUT cell is only 600 μ m . The ultrasonic time of flight (TOF) difference method is employed to measure the gas flow rate, followed by ultrasonic signal processing and subsequent velocity profile and temperature compensation performed by the microcontroller. The cross correlation method is employed to detect the ultrasonic TOF difference and further suppress noise. In order to conduct a feasibility evaluation of the designed ultrasonic gas meter, the PMUT array, system control circuit and ultrasonic flow channel are combined and encapsulated in a meter case. Results indicate that the ultrasonic gas meter exhibits outstanding accuracy, repeatability and temperature adaptability. In the flow range of 0.025 m 3 /h to 2.8 m 3 /h, the minimum mean error and minimum repeatability error are 0.11% and 0.13%, respectively. Even when the temperature reaches 323.15 K, the designed device can achieve a mean error of no more than 0.41% with temperature compensation, which is comparable to commercialized ultrasonic gas meters. The highly reliable ultrasonic gas meter presented in this paper will provide a feasible solution for advancing portable devices.