Syahar Azalia Ab Shukor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Syahar Azalia Ab Shukor has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Atikah Razi
Department of Diploma Engineering Faculty of Electrical Technology and Engineering Universiti Teknikal Malaysia Melaka (UTeM) Melaka Malaysia
2 shared publications - Auzani Jidin
Universiti Teknikal Malaysia Melaka
1 shared publication - Azziddin Mohamad Razali
Universiti Teknikal Malaysia Melaka (UTeM)
1 shared publication - Fardila Mohd Zaihidee
Faculty of Technical and Vocational, Universiti Pendidikan Sultan Idris, 35900 Tanjong Malim, Perak, Malaysia
1 shared publication - Muhamad Nabil Hidayat
Universiti Teknologi MARA
1 shared publication - Muhammad Hafeez Mohamed Hariri
Universiti Sains Malaysia (USM)
1 shared publication
Latest Publications
- Open Access
- 1 February 2026
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 15 (1) , 875-883
PID controller tuning performance evaluation based on integral time square error for coupled tank system
This study presents a conclusive performance evaluation based on integral time between the conventional and optimization based proportional integral derivatives (PID) tuning method. The tuning method of interest are including trial and error, auto-tuning, Ziegler-Nichols (ZN), Cohen-Coon (CC), and particle swarm optimization (PSO). The coupled tank system (CTS) is used for the system under consideration as it’s one of the popular technologies in industrial control application. Previous study had compared the tuning performance in terms of its transient response. The transient consists of several parameters such as rise time (Tr), settling time (Ts), peak time (Tp), steady state error, overshoot, and steady state error. Due to that, a conclusive performance comparison could not be achieved. Hence this study proposed integral time squared error evolution which is based on only one parameter which also reflects good overall transient response performance. The results show that of all tuning methods, PSO provide the smallest integral time square error (ITSE) value, while trial and error provide the highest with a value of 12.84 and 203.10, respectively. The ITSE also reflects the transient response performances.
- 1 February 2026
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 15 (1) , 875-883
Open AccessPID controller tuning performance evaluation based on integral time square error for coupled tank system
This study presents a conclusive performance evaluation based on integral time between the conventional and optimization based proportional integral derivatives (PID) tuning method. The tuning method of interest are including trial and error, auto-tuning, Ziegler-Nichols (ZN), Cohen-Coon (CC), and particle swarm optimization (PSO). The coupled tank system (CTS) is used for the system under consideration as it’s one of the popular technologies in industrial control application. Previous study had compared the tuning performance in terms of its transient response. The transient consists of several parameters such as rise time (Tr), settling time (Ts), peak time (Tp), steady state error, overshoot, and steady state error. Due to that, a conclusive performance comparison could not be achieved. Hence this study proposed integral time squared error evolution which is based on only one parameter which also reflects good overall transient response performance. The results show that of all tuning methods, PSO provide the smallest integral time square error (ITSE) value, while trial and error provide the highest with a value of 12.84 and 203.10, respectively. The ITSE also reflects the transient response performances.
- Open Access
- 1 April 2025
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 38 (1) , 63-75
Analysis of VFDPC for three-level neutral point clamped AC-DC converters with capacitor balancing s
This paper presents an analysis of the dynamic performance of a three-level neutral point clamped (NPC) AC-DC converter utilizing the advanced control technique of virtual flux direct power control (VFDPC). VFDPC estimates the three-phase grid voltage and instantaneous active and reactive power components, eliminating the need for an AC input voltage sensor used in conventional direct power control (DPC). This reduction in sensors decreases system complexity and cost while mitigating high-frequency noise and interference. Integrating VFDPC into 3L NPC AC-DC converters significantly enhances overall performance, leading to more efficient and robust power conversion systems. However, a significant challenge in the three-level NPC topology is the voltage imbalance in the neutral point of the DC-link capacitor, which can cause excessive voltage stress on switching devices and degrade system performance. To address this, a novel lookup table has been developed, incorporating strategies to balance the capacitor voltage. The results of this study demonstrate that VFDPC generates nearly sinusoidal line currents with reduced current total harmonic distortion (THD). Additionally, VFDPC ensures unity, lagging, and leading power factor operation, while providing flexibility to adjust the DC-link output voltage and accommodate load variations. These capabilities highlight VFDPC effectiveness in managing power quality and system stability, even under varying load conditions.
- 1 April 2025
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 38 (1) , 63-75
Open AccessAnalysis of VFDPC for three-level neutral point clamped AC-DC converters with capacitor balancing s
This paper presents an analysis of the dynamic performance of a three-level neutral point clamped (NPC) AC-DC converter utilizing the advanced control technique of virtual flux direct power control (VFDPC). VFDPC estimates the three-phase grid voltage and instantaneous active and reactive power components, eliminating the need for an AC input voltage sensor used in conventional direct power control (DPC). This reduction in sensors decreases system complexity and cost while mitigating high-frequency noise and interference. Integrating VFDPC into 3L NPC AC-DC converters significantly enhances overall performance, leading to more efficient and robust power conversion systems. However, a significant challenge in the three-level NPC topology is the voltage imbalance in the neutral point of the DC-link capacitor, which can cause excessive voltage stress on switching devices and degrade system performance. To address this, a novel lookup table has been developed, incorporating strategies to balance the capacitor voltage. The results of this study demonstrate that VFDPC generates nearly sinusoidal line currents with reduced current total harmonic distortion (THD). Additionally, VFDPC ensures unity, lagging, and leading power factor operation, while providing flexibility to adjust the DC-link output voltage and accommodate load variations. These capabilities highlight VFDPC effectiveness in managing power quality and system stability, even under varying load conditions.
- Open Access
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 15 (4) , 2651-2659
Low-voltage DC-DC off-grid PV system: various irradiance studies
The off-grid photovoltaic (OGPV) system, also referred to as a stand-alone power system, generates electricity from solar energy independently of the main electricity grid. However, photovoltaic (PV) modules face limitations in consistently providing the necessary voltage. Thus, a DC-DC converter is employed to adjust the voltage to match the requirements of the load. This paper proposes a detailed analysis of irradiance patterns resembling in-lab and real-world conditions to address the challenge of selecting the optimal DC-DC OGPV system capable of functioning effectively under standard test condition (STC) and dynamic test condition (DTC), respectively. Three proposed irradiance analyses, tailored to different environmental scenarios, aim to identify output performances for DC-DC OGPV system which are aligning with standards set by the International Electrotechnical Commission (IEC) 61727. The DC-DC OGPV system is simulated using MATLAB Simulink. Furthermore, comparative studies involving different PV module types and several switching techniques (pulse generator and maximum power point tracking or MPPT implementations), where findings are instrumental in advancing the development and projection planning for medium to high-voltage OGPV systems, contributing to the global initiative for accessible and sustainable energy solutions aligned with sustainable development goal (SDG 7).
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 15 (4) , 2651-2659
Open AccessLow-voltage DC-DC off-grid PV system: various irradiance studies
The off-grid photovoltaic (OGPV) system, also referred to as a stand-alone power system, generates electricity from solar energy independently of the main electricity grid. However, photovoltaic (PV) modules face limitations in consistently providing the necessary voltage. Thus, a DC-DC converter is employed to adjust the voltage to match the requirements of the load. This paper proposes a detailed analysis of irradiance patterns resembling in-lab and real-world conditions to address the challenge of selecting the optimal DC-DC OGPV system capable of functioning effectively under standard test condition (STC) and dynamic test condition (DTC), respectively. Three proposed irradiance analyses, tailored to different environmental scenarios, aim to identify output performances for DC-DC OGPV system which are aligning with standards set by the International Electrotechnical Commission (IEC) 61727. The DC-DC OGPV system is simulated using MATLAB Simulink. Furthermore, comparative studies involving different PV module types and several switching techniques (pulse generator and maximum power point tracking or MPPT implementations), where findings are instrumental in advancing the development and projection planning for medium to high-voltage OGPV systems, contributing to the global initiative for accessible and sustainable energy solutions aligned with sustainable development goal (SDG 7).