XZXiao-Hong Zhu

Xiao-Hong Zhu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiao-Hong Zhu has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    High-Resolution Brain Metabolic Imaging at Ultrahigh Field Using Extended Spatiospectral Encoding and Subspace Modeling

    by Rong Guo, Yudu Li, Yibo Zhao, Wen Jin, Yuhui Chai, Aaron Anderson, Wael Hassaneen, Bruce Damon, Tracey Wszalek, Yao Li, et al.

    Objective: To develop a high-resolution magnetic resonance (MR) metabolic imaging method for mapping human brain metabolite distributions at ultrahigh field (7T). Methods: In data acquisition, a free-induction-decay (FID) based MR spectroscopic imaging (MRSI) sequence was implemented. To achieve high spatial resolution, the sequence used fast echo-planar spectroscopic imaging (EPSI) trajectories with echo-spacings larger than the Nyquist sampling interval. Using this sequence, 3D MRSI signals at isotropic nominal resolutions of 3.0 mm and 1.8 mm were acquired within scan times of 4.8 and 14.2 minutes, respectively. In data processing, model-based methods integrating subspace learning, spectral modeling, and generalized series modeling were developed to address key challenges, including spectral ghosting, low signal-to-noise ratio, and spectral aliasing. Results: The proposed acquisition and processing methods successfully generated high-resolution, high-quality metabolite maps of the human brain at 7T. Experimental results from phantom and in vivo scans validated the proposed method and showed its capability to capture detailed brain metabolite distributions. Conclusion: This work demonstrates the feasibility of high-resolution brain metabolic imaging at ultrahigh field using MRSI acquisition sequence and model-based processing methods. Significance: By providing high-resolution spatial mapping of brain metabolites within clinically feasible scan times, the proposed method promises to offer a powerful imaging tool for investigating brain metabolism, which is expected to be useful for various brain imaging applications.


  • Open Access

    Quantitative mapping of key glucose metabolic rates in the human brain using dynamic deuterium magnetic resonance spectroscopic imaging

    by Xin Li, Xiao-Hong Zhu, Yudu Li, Tao Wang, Guangle Zhang, Hannes M Wiesner, Zhi-Pei Liang, Wei Chen

    Deuterium (2H) magnetic resonance spectroscopic imaging (DMRSI) is a newly developed technology for assessing glucose metabolism by simultaneously measuring deuterium-labeled glucose and its downstream metabolites (1) and has a potential to provide a powerful neurometabolic imaging tool for quantitative studies of cerebral glucose metabolism involving multiple metabolic pathways in the human brain. In this work, we developed a dynamic DMRSI method that combines advanced radiofrequency coil and postprocessing techniques to substantially improve the imaging signal-to-noise ratio for detecting deuterated metabolites and enable robust dynamic DMRSI of the human brain at 7 T with very high resolution (HR; 0.7 cc nominal voxel and 2.5 min/image) and whole-brain coverage. Utilizing this capability, we were able to map and differentiate metabolite contents and dynamics throughout the human brain following oral administration of deuterated glucose. Furthermore, by introducing a sophisticated kinetic model, we demonstrated that three key cerebral metabolic rates of glucose consumption (CMRGlc), lactate production (CMRLac), and tricarboxylic acid (TCA) cycle (VTCA), as well as the maximum apparent rate of forward glucose transport (Tmax) can be simultaneously imaged in the human brain through a single dynamic DMRSI measurement. The results clearly show that the glucose transport, neurotransmitter turnover, CMRGlc, and VTCA are significantly higher in gray matter than in white matter in the human brain; and the mean metabolic rates and their ratios measured in this study are consistent with the values reported in the literature. The HR dynamic DMRSI methodology presented herein is of great significance and value for the quantitative assessment of human brain glucose metabolism, aerobic glycolysis, and metabolic reprogramming under physiopathological conditions.


  • Open Access

    A novel multifrequency‐tuned transceiver array for human‐brain 31 P ‐ MRSI at 7 T

    by Xin Li, Xiao‐Hong Zhu, Xiao‐Liang Zhang, Matt Waks, Wei Chen

    Purpose: Phosphorus‐31 ( 31 P) MR spectroscopy imaging (MRSI) at 7 T is a powerful tool for investigating high‐energy phosphate metabolism in human brains with significantly improved signal‐to‐noise ratio (SNR) and spectral resolution. However, this imaging technique requires dual‐frequency radiofrequency coil for performing brain anatomical imaging and B 0 shimming at proton ( 1 H) operation frequency, and 31 P MRSI at lower operation frequency. Herein, we introduce a novel 31 P‐ 1 H dual‐frequency radiofrequency coil design using a double‐tuned and double‐matched (DODO) coil that does not require complex circuitry or two coil layers and exhibits similar imaging performance as to single‐frequency control coils for both 31 P and 1 H imaging operations. Methods: We constructed an eight‐element 31 P‐ 1 H dual‐frequency DODO transceiver array and compared its performance with a quadrature‐driven dual‐tuned eight‐element 31 P and eight‐element 1 H transverse electromagnetic volume coil for both phantom and in vivo human‐brain 31 P‐MRSI studies at 7 T. Results: The DODO transceiver array achieved high spatiotemporal resolution 31 P MRSI with 2.5‐cc nominal voxel size and 22‐min scan time covering the entire human brain, showing excellent SNR for mapping cerebral phosphorous metabolites such as phosphocreatine, adenosine triphosphate, and other low‐concentration metabolites. Compared with the transverse electromagnetic volume coil, the DODO array demonstrated large improvements in 31 P‐MRSI SNR in both phantom and human brain studies, with over 5‐fold SNR gain in peripheral regions and over 2‐fold SNR gain in central brain regions. Conclusion: This simple and cost‐effective array design and excellent performance can greatly benefit human‐brain 31 P‐MRSI applications at 7 T.


  • Open Access

    Large improvement in RF magnetic fields and imaging SNR with whole‐head high‐permittivity slurry helmet for human‐brain MRI applications at 7 T

    by Soo Han Soon, Xin Li, Matt Waks, Xiao‐Hong Zhu, Hannes M. Wiesner, Navid P. Gandji, Qing X. Yang, Michael T. Lanagan, Wei Chen

    Purpose: To optimize the design and demonstrate the integration of a helmet‐shaped container filled with a high‐permittivity material (HPM) slurry with RF head coil arrays to improve RF coil sensitivity and SNR for human‐brain proton MRI.Methods: RF reception magnetic fields () of a 32‐channel receive‐only coil array with various geometries and permittivity values of HPM slurry helmet are calculated with electromagnetic simulation at 7 T. A 16‐channel transmit‐only coil array, a 32‐channel receive‐only coil array, and a 2‐piece HPM slurry helmet were constructed and assembled. RF transmission magnetic field (), , and MRI SNR maps from the entire human brain were measured and compared.Results: Simulations showed that averaged improvement with the HPM slurry helmet increased from 57% to 87% as the relative permittivity (εr) of HPM slurry increased from 110 to 210. In vivo experiments showed that the average improvement over the human brain was 14.5% with the two‐piece HPM slurry (εr ≈ 170) helmet, and the average and SNR were improved 63% and 34%, respectively, because the MRI noise level was increased by the lossy HPM.Conclusion: The RF coil sensitivity and MRI SNR were largely improved with the two‐piece HPM slurry helmet demonstrated by both electromagnetic simulations and in vivo human head experiments at 7 T. The findings demonstrate that incorporating an easily producible HPM slurry helmet into the RF coil array significantly enhances human‐brain MRI SNR homogeneity and quality at ultrahigh field. Greater SNR improvement is anticipated using the less lossy HPM and optimal design.


  • Open Access

    Novel Composite Gold-Aluminum Electrode with Application to Neural Recording and Stimulation in Ultrahigh Field Magnetic Resonance Imaging Scanners

    by Corey E. Cruttenden, Mahdi Ahmadi, Yi Zhang, Xiao-Hong Zhu, Wei Chen, Rajesh Rajamani

    Traditional electrodes used for neural recording and stimulation generate large regions of signal void (no functional MRI signal) when used in ultrahigh field (UHF) MRI scanners. This is a significant disadvantage when simultaneous neural recording/stimulation and fMRI signal acquisition is desired, for example in understanding the functional mechanisms of deep brain stimulation (DBS). In this work, a novel gold-aluminum microwire neural electrode is presented which overcomes this disadvantage. The gold-aluminum design greatly reduces the magnetic susceptibility difference between the electrode and brain tissue leading to significantly reduced regions of signal void. Gold-aluminum microwire samples are imaged at ultrahigh field 16.4 Tesla and compared with gold-only and aluminum-only microwire samples. First, B0 field mapping was used to quantify field distortions at 16.4T and compared with analytical computations in an agarose phantom. The gold-aluminum microwire samples generated substantially less field distortion and signal loss in comparison with gold-only and aluminum-only samples at 16.4T using gradient echo imaging and echo planar imaging sequences. Next, the proposed gold-aluminum electrode was used to successfully record local field potential signals from a rat cortex. The newly proposed gold-aluminum microwire electrode exhibits reduced field distortions and signal loss at 16.4T, a finding which translates to MRI scanners of lower magnetic field strengths as well. The design can be easily reproduced for widespread study of DBS using MRI in animal models. Additionally, the use of non-reactive gold and aluminum materials presents an avenue for translation to human implant applications in the future.