CCCamilla Giulia Calastra

Camilla Giulia Calastra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Camilla Giulia Calastra has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Annapaola Parrilli

    EMPA—Swiss Federal Laboratories for Materials Science and Technology, 8600 Dübendorf, Switzerland

    2 shared publications
  • Federica Orellana

    Center for X-Ray Analytics, Empa—Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, 8600 Dübendorf, Switzerland

    2 shared publications
  • Raluca-Ana-Maria Barna

    Center for X-Ray Analytics, Empa—Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, 8600 Dübendorf, Switzerland

    2 shared publications
  • Ada Ayechu Abendaño

    Department of Engineering, Public University of Navarra (UPNA), Campus Arrosadía s/n, 31006 Pamplona, Spain

    1 shared publication
  • Adrian Huber

    Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland

    1 shared publication
  • Alan Arthur Peters

    Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland

    1 shared publication

Latest Publications

  • Open Access

    The Role of Angiographic Imaging in the Treatment of Spinal Vascular Malformations

    by Camilla Giulia Calastra, Ada Ayechu Abendaño, Raluca-Ana-Maria Barna, Federica Orellana, Simone Baffelli, Ameet Aiyangar, Annapaola Parrilli

    Spinal vascular malformations (SVMs) are rare and heterogeneous lesions that may lead to progressive neurological decline or hemorrhage, posing significant challenges for management due to their complex angioarchitecture and proximity to critical neural structures. This review examines the role of angiographic imaging modalities used intraoperatively and postoperatively in guiding treatment, confirming therapeutic success, and informing follow-up strategies. We summarize evidence on two-dimensional digital subtraction angiography (2D DSA), indocyanine green videoangiography (ICG–VAG), and emerging adjunctive techniques. 2D DSA remains the reference standard, offering superior temporal and spatial resolution for real-time visualization of vascular anatomy, catheter navigation, and embolic delivery, though its invasive nature, radiation exposure, and two-dimensional projection limit long-term applicability. ICG–VAG provides a complementary, non-ionizing method for intraoperative fluorescence imaging, aiding in shunt localization and venous preservation, although its restricted field of view and limited capacity for quantitative analysis reduce its standalone value. Advances in quantitative angiographic metrics, patient-specific hemodynamic modeling, and artificial intelligence-driven image analysis are anticipated to enhance diagnostic accuracy and reproducibility. The development of standardized multimodal protocols will be crucial for optimizing patient-centered treatment of these complex and rare lesions.


  • Open Access

    Hemodynamic Characterization of Peripheral Arterio-Venous Malformations Using Rapid Contrast-Enhanced MR Imaging: An In Vitro and In Vivo Study

    by Camilla Giulia Calastra, Marika Bono, Aloma Blanch Granada, Aleksandra Tuleja, Sarah Maike Bernhard, Vanessa Diaz-Zuccarini, Stavroula Balabani, Dominik Obrist, Hendrik von Tengg-Kobligk, Bernd Jung

    Purpose: Peripheral arterio-venous malformations (pAVMs) are vascular defects often requiring extensive medical treatment. To improve disease management, hemodynamic markers based on 2D Digital Subtraction Angiography (DSA) data were previously defined to classify pAVMs. However, DSA offers only 2D information, involves ionizing radiation, and requires intra-arterial intervention. We hypothesized that pAVMs could be classified with the same approach with 3D dynamic contrast-enhanced MR-based data. To this end, the present work aims to develop a computational classification system for pAVMs using 3D dynamic contrast-enhanced MR-based data. Methods: A pAVM phantom was imaged using both DSA and MRI to validate the methodology, which was then applied to 10 MR-based in vivo datasets. A semi-automated vessel detection algorithm, based on the standard deviation of each voxel or pixel in time, was used. Classification was performed by identifying the time of arrival (CAToA) of contrast agent (CA) and the maximum time derivative of the CA transport in each pixel or voxel (CAsi). Results: Normalized CAToA and CAsi histograms showed no significant difference between in vitro DSA and MRI (respectively χ 2 = 0.20, p = 0.65 and χ 2 = 0.21, p = 0.65), validating the methodology to classify pAVMs. CAToA histograms for type II–IV AVMs derived from in vivo MR-based data aligned with DSA patterns and known hemodynamics. CAToA histograms of capillary–venulous AVMs were distinct, with non-zero values at later times than other AVM types, representing late venous drainage. Type IV AVMs histograms for CAsi were more right-skewed than those derived from types II and III pAVMs. Conclusions: MR image quality and temporal resolution are sufficient to allow a classification of pAVMs. This classification method has the potential to become a diagnostic tool for the surgical navigation of pAVMs for clinicians.


  • Open Access

    Imaging Techniques for Meniscal Vasculature: A Systematic Review of Clinical and Translational Applications

    by Federica Orellana, Raluca-Ana-Maria Barna, Camilla Giulia Calastra, Annapaola Parrilli

    Purpose: The focus of this review is on the imaging techniques used to visualize the meniscal vascular network and arteries in clinical, human ex vivo, and animal model applications. For this purpose, research articles from the past decade that have imaged the vascular network of the meniscus and/or the genicular and popliteal arteries were identified according to established PRISMA statement standards. Methods: Various imaging modalities, including magnetic resonance imaging, micro-computed tomography, and optical and fluorescence microscopy, were included and compared based on the type of visualization, imaging resolution, and range of vessel size detection. These imaging modalities were evaluated based on the outcomes of interest, including diagnostic accuracy in identifying the meniscal vasculature and associated pathologies, clinical applications to guide surgical decisions, and translational applications contributing to the research and development of new therapies and the understanding of meniscal physiology and pathology. Results: The analysis conducted in this study highlights the importance of imaging resolution and visualization type in accurately depicting the complex microvasculature of the meniscus with high precision and detail. Conclusions: This review underscores the necessity for high-resolution 3D imaging techniques to comprehensively understand the meniscal vascular network and enhance surgical approaches and treatment options for meniscal lesions and pathologies.


  • Open Access

    Dynamic contrast-enhanced MRA of the aorta using a Golden-angle RAdial Sparse Parallel (GRASP) sequence: comparison with conventional time-resolved cartesian MRA (TWIST)

    by Camilla Giulia Calastra, Elena Kleban, Fabrice Noël Helfenstein, Fabian Haupt, Alan Arthur Peters, Adrian Huber, Hendrik von Tengg-Kobligk, Bernd Jung

    Purpose: To compare the application of two contrast-enhanced time-resolved magnetic resonance angiography sequences on an aortic disease patient cohort: the conventional Cartesian-sampling-based, Time-resolved angiography With Interleaved Stochastic Trajectories (TWIST) sequence, and the radial-sampling-based Golden-angle RAdial Sparse Parallel (GRASP) sequence. TWIST is highly sensitive to patient movement, which can lead to blurring and reduced sharpness of vascular structures, particularly in dynamic regions like the aorta. Such motion artifacts can compromise diagnostic accuracy. Radial-sampling-based techniques are less sensitive to motion than cartesian sampling and are expected to improve the image quality in body parts subjected to motion. Methods: 30 patients (60.9 ± 16.1y.o.) with various aortic diseases underwent a 1.5T magnetic resonance angiography examination. Assessment of image quality in the ascending aorta (AA), descending aorta (DA), and abdominal aorta (AbA) on a 4-point Likert scale (1 = excellent, 4 = non-diagnostic) as well as max. aortic diameters (Dmax) were performed. T-test and multilevel mixed-effect proportional-odds models were used for the image analysis. Results: GRASP offered superior depiction of vascular structures in terms of vascular contrast for qualitative analysis (TWIST, reader 1: 1.6 ± 0.5; reader 2: 1.9 ± 0.4; reader 3: 1.1 ± 0.4; GRASP, reader 1: 1.5 ± 0.5; reader 2: 1.4 ± 0.5; reader 3: 1.0 ± 0.2) and vessel sharpness for qualitative (TWIST, reader 1: 1.9 ± 0.6; reader 2: 1.6 ± 0.6; reader 3: 2.0 ± 0.3; GRASP, reader 1: 1.4 ± 0.6; reader 2: 1.2 ± 0.4; reader 3: 1.3 ± 0.6) and quantitative analysis (TWIST, AA = 0.12 ± 0.04, DA = 0.12 ± 0.03, AbA = 0.11 ± 0.03; GRASP, AA = 0.20 ± 0.05, DA = 0.22 ± 0.06, AbA=0.20 ± 0.05). Streaking artefacts of GRASP were more visible compared to TWIST (TWIST, reader 1: 2.2 ± 0.6; reader 2: 1.9 ± 0.3; reader 3: 2.0 ± 0.5; GRASP, reader 1: 2.6 ± 0.6; reader 2: 2.3 ± 0.5; reader 3: 2.8 ± 0.6). Aortic Dmax comparison among the sequence showed no clinical relevance. Conclusion: GRASP outperformed TWIST in SNR, vessel sharpness, and reduction in image blurring; streaking artefacts were stronger with GRASP, but did not affect diagnostic image quality.