Ada Ayechu Abendaño
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ada Ayechu Abendaño has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ameet K. Aiyangar
Mechanical Systems Engineering, Empa – Swiss Federal Laboratories for Materials Science and Technology, Dübendorf, Switzerland
1 shared publication - Annapaola Parrilli
EMPA—Swiss Federal Laboratories for Materials Science and Technology, 8600 Dübendorf, Switzerland
1 shared publication - Camilla Giulia Calastra
Center for X-Ray Analytics, Empa—Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, 8600 Dübendorf, Switzerland
1 shared publication - Carmen Sánchez González
Asociación de la Industria Navarra. Carretera Pamplona 1, 31191 Cordovilla, Navarra, Spain
1 shared publication - Carmen Sánchez-Matás
Department of Thoracic Surgery, University Hospital Virgen de la Arrixaca, Ctra. Madrid-Cartagena, s/n, 30120 El Palmar, Spain
1 shared publication - Cristina Díaz Jiménez
AIN—Asociación de la Industria Navarra, Ctra. Pamplona, 1. Edif. AIN, E-31191 Cordovilla, Spain
1 shared publication
Latest Publications
- Open Access
- 20 August 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (8) , 419
A Computational Framework for the Design and Mechanical Assessment of Biodegradable Airway Stents: Interaction with Rabbit Tracheal Tissue and Preliminary In Vivo Observations
Current airway stents, including silicone and metallic devices, remain associated with important complications such as migration, restenosis, mucus retention and the need for repeated interventions. Biodegradable stents offer a promising alternative by providing temporary mechanical support while avoiding the long-term presence of a permanent implant. However, the influence of stent geometry and material properties on their mechanical performance and interaction with airway tissue is still not fully understood. This study presents a computational framework integrating computer-aided design and finite element analysis to investigate the mechanical behaviour of biodegradable tracheobronchial stents. Two stent architectures (X-pattern and W-pattern) were analysed over a range of wire thicknesses using two biodegradable materials: a PLA/PCL; 70/30 wt.% blend and AZ31 magnesium alloy. Radial compression, diameter recovery after radial compression and stent–tissue interaction simulations were performed to evaluate the influence of geometry, material selection and design parameters on device performance. The results suggested that both stent geometry and material properties strongly influence the mechanical behaviour of biodegradable airway stents, although they affect different aspects of the stent–tissue interaction. The X-pattern consistently exhibited greater resistance to radial compression, lower elastic diameter recovery after radial compression and improved maintenance of the expanded lumen compared with the W-pattern. Material properties primarily affected the magnitude of the mechanical response, as further confirmed by the quantitative contact-pressure analysis, with AZ31 providing greater radial support, while the spatial distributions of stress and strain within the tracheal wall were mainly governed by the stent architecture. Based on the computational analyses, X-pattern stents manufactured from the PLA/PCL; 70/30 wt.% blend were selected for in vivo evaluation in a rabbit model. Endoscopic observations revealed tissue features that were qualitatively consistent with the mechanical patterns predicted by the numerical simulations, although no direct causal relationship can be established from the available observations. These findings support the ability of the proposed framework to represent the principal aspects of stent–tissue interaction. The proposed computational framework provides a practical tool for the rational design and mechanical assessment of biodegradable airway stents and may facilitate the future development of customised airway prostheses.
- 20 August 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (8) , 419
Open AccessA Computational Framework for the Design and Mechanical Assessment of Biodegradable Airway Stents: Interaction with Rabbit Tracheal Tissue and Preliminary In Vivo Observations
Current airway stents, including silicone and metallic devices, remain associated with important complications such as migration, restenosis, mucus retention and the need for repeated interventions. Biodegradable stents offer a promising alternative by providing temporary mechanical support while avoiding the long-term presence of a permanent implant. However, the influence of stent geometry and material properties on their mechanical performance and interaction with airway tissue is still not fully understood. This study presents a computational framework integrating computer-aided design and finite element analysis to investigate the mechanical behaviour of biodegradable tracheobronchial stents. Two stent architectures (X-pattern and W-pattern) were analysed over a range of wire thicknesses using two biodegradable materials: a PLA/PCL; 70/30 wt.% blend and AZ31 magnesium alloy. Radial compression, diameter recovery after radial compression and stent–tissue interaction simulations were performed to evaluate the influence of geometry, material selection and design parameters on device performance. The results suggested that both stent geometry and material properties strongly influence the mechanical behaviour of biodegradable airway stents, although they affect different aspects of the stent–tissue interaction. The X-pattern consistently exhibited greater resistance to radial compression, lower elastic diameter recovery after radial compression and improved maintenance of the expanded lumen compared with the W-pattern. Material properties primarily affected the magnitude of the mechanical response, as further confirmed by the quantitative contact-pressure analysis, with AZ31 providing greater radial support, while the spatial distributions of stress and strain within the tracheal wall were mainly governed by the stent architecture. Based on the computational analyses, X-pattern stents manufactured from the PLA/PCL; 70/30 wt.% blend were selected for in vivo evaluation in a rabbit model. Endoscopic observations revealed tissue features that were qualitatively consistent with the mechanical patterns predicted by the numerical simulations, although no direct causal relationship can be established from the available observations. These findings support the ability of the proposed framework to represent the principal aspects of stent–tissue interaction. The proposed computational framework provides a practical tool for the rational design and mechanical assessment of biodegradable airway stents and may facilitate the future development of customised airway prostheses.
- Open Access
- 13 November 2025
- Published by MDPI AG in Medical Sciences
- Vol. 13 (4) , 266
The Role of Angiographic Imaging in the Treatment of Spinal Vascular Malformations
Spinal vascular malformations (SVMs) are rare and heterogeneous lesions that may lead to progressive neurological decline or hemorrhage, posing significant challenges for management due to their complex angioarchitecture and proximity to critical neural structures. This review examines the role of angiographic imaging modalities used intraoperatively and postoperatively in guiding treatment, confirming therapeutic success, and informing follow-up strategies. We summarize evidence on two-dimensional digital subtraction angiography (2D DSA), indocyanine green videoangiography (ICG–VAG), and emerging adjunctive techniques. 2D DSA remains the reference standard, offering superior temporal and spatial resolution for real-time visualization of vascular anatomy, catheter navigation, and embolic delivery, though its invasive nature, radiation exposure, and two-dimensional projection limit long-term applicability. ICG–VAG provides a complementary, non-ionizing method for intraoperative fluorescence imaging, aiding in shunt localization and venous preservation, although its restricted field of view and limited capacity for quantitative analysis reduce its standalone value. Advances in quantitative angiographic metrics, patient-specific hemodynamic modeling, and artificial intelligence-driven image analysis are anticipated to enhance diagnostic accuracy and reproducibility. The development of standardized multimodal protocols will be crucial for optimizing patient-centered treatment of these complex and rare lesions.
- 13 November 2025
- Published by MDPI AG in Medical Sciences
- Vol. 13 (4) , 266
Open AccessThe Role of Angiographic Imaging in the Treatment of Spinal Vascular Malformations
Spinal vascular malformations (SVMs) are rare and heterogeneous lesions that may lead to progressive neurological decline or hemorrhage, posing significant challenges for management due to their complex angioarchitecture and proximity to critical neural structures. This review examines the role of angiographic imaging modalities used intraoperatively and postoperatively in guiding treatment, confirming therapeutic success, and informing follow-up strategies. We summarize evidence on two-dimensional digital subtraction angiography (2D DSA), indocyanine green videoangiography (ICG–VAG), and emerging adjunctive techniques. 2D DSA remains the reference standard, offering superior temporal and spatial resolution for real-time visualization of vascular anatomy, catheter navigation, and embolic delivery, though its invasive nature, radiation exposure, and two-dimensional projection limit long-term applicability. ICG–VAG provides a complementary, non-ionizing method for intraoperative fluorescence imaging, aiding in shunt localization and venous preservation, although its restricted field of view and limited capacity for quantitative analysis reduce its standalone value. Advances in quantitative angiographic metrics, patient-specific hemodynamic modeling, and artificial intelligence-driven image analysis are anticipated to enhance diagnostic accuracy and reproducibility. The development of standardized multimodal protocols will be crucial for optimizing patient-centered treatment of these complex and rare lesions.