Critical Crevice Temperature of 2205 Duplex Stainless Steel in Fe(III)/Fe(II)-Buffered Acidic Chloride Solutions
The critical crevice temperature (CCT) of 2205 duplex stainless steel was evaluated in acidic chloride solutions representative of hydrometallurgical leach liquors (50 g·L⁻¹ H₂SO₄, 0–15 g·L⁻¹ Cl⁻) containing the Fe(III)/Fe(II) redox couple at ratios of 1:10, 1:1, and 1000:1. Conventional electrochemical CCT methods are unreliable in redox-buffered environments. Under potentiostatic control, bulk Fe(II) oxidation dominated the measured current, obscuring the crevice corrosion response. open-circuit potential (OCP) ramping overestimated CCT by up to 45 °C relative to immersion testing. This discrepancy arises from temperature-dependent acceleration of Fe(III)/Fe(II) redox kinetics, which increases exchange current density and reduces mixed-potential sensitivity to localized attack. Immersion testing was therefore required to obtain physically meaningful CCT values. Within 1–10 g·L⁻¹ total Fe, CCT was insensitive to iron concentration at constant Fe(III)/Fe(II) ratio and chloride concentration, indicating that redox buffering—not total oxidant concentration—controls crevice stability. Increasing chloride decreased CCT from 98.7 °C to 39.9 °C, while Fe(III)/Fe(II) further reduced CCT by 10–20 °C. At 15 g·L⁻¹ Cl⁻ and a 1000:1 ratio, crevice corrosion initiated at room temperature. These results show that redox buffering and chloride synergistically destabilize passive films in confined geometries and that electrochemical techniques may misrepresent localized corrosion resistance in hydrometallurgical environments.
- 21 April 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (9)
Open AccessCritical Crevice Temperature of 2205 Duplex Stainless Steel in Fe(III)/Fe(II)-Buffered Acidic Chloride Solutions
The critical crevice temperature (CCT) of 2205 duplex stainless steel was evaluated in acidic chloride solutions representative of hydrometallurgical leach liquors (50 g·L⁻¹ H₂SO₄, 0–15 g·L⁻¹ Cl⁻) containing the Fe(III)/Fe(II) redox couple at ratios of 1:10, 1:1, and 1000:1. Conventional electrochemical CCT methods are unreliable in redox-buffered environments. Under potentiostatic control, bulk Fe(II) oxidation dominated the measured current, obscuring the crevice corrosion response. open-circuit potential (OCP) ramping overestimated CCT by up to 45 °C relative to immersion testing. This discrepancy arises from temperature-dependent acceleration of Fe(III)/Fe(II) redox kinetics, which increases exchange current density and reduces mixed-potential sensitivity to localized attack. Immersion testing was therefore required to obtain physically meaningful CCT values. Within 1–10 g·L⁻¹ total Fe, CCT was insensitive to iron concentration at constant Fe(III)/Fe(II) ratio and chloride concentration, indicating that redox buffering—not total oxidant concentration—controls crevice stability. Increasing chloride decreased CCT from 98.7 °C to 39.9 °C, while Fe(III)/Fe(II) further reduced CCT by 10–20 °C. At 15 g·L⁻¹ Cl⁻ and a 1000:1 ratio, crevice corrosion initiated at room temperature. These results show that redox buffering and chloride synergistically destabilize passive films in confined geometries and that electrochemical techniques may misrepresent localized corrosion resistance in hydrometallurgical environments.
- Open Access
- 12 August 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (8)
Fe(III)-Fe(II) Redox Kinetics and their Effects on 2205 Duplex Stainless Steel Corrosion
The kinetics of the Fe(III)/Fe(II) redox couple on 2205 duplex stainless steel (DSS) were studied in 0.5 M H₂SO₄ at 25, 60, and 95°C, across Fe(III)/Fe(II) ratios of 1:10, 1:1, and 1000:1. A novel method was developed to isolate the mixed potential, applied to DSS for the first time. The reversible potential (Erev) was maintained within the passive range (0–1 V vs SHE) to minimize corrosion. PDP and 60-day immersion tests confirmed passivity with 0.95). At a 1:1 Fe(III)/Fe(II) ratio, temperature variation from 25 to 95°C has little impact on E₍rev₎, which remains stable at 0.65–0.68 V vs SHE. In contrast, increasing the Fe(III)/Fe(II) ratio markedly raises E₍rev₎ from 0.60 V to 0.86 V. Despite these shifts, E₍rev₎ stays within the passive region, providing anodic protection and minimizing crevice and pitting risks.
- 12 August 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (8)
Open AccessFe(III)-Fe(II) Redox Kinetics and their Effects on 2205 Duplex Stainless Steel Corrosion
The kinetics of the Fe(III)/Fe(II) redox couple on 2205 duplex stainless steel (DSS) were studied in 0.5 M H₂SO₄ at 25, 60, and 95°C, across Fe(III)/Fe(II) ratios of 1:10, 1:1, and 1000:1. A novel method was developed to isolate the mixed potential, applied to DSS for the first time. The reversible potential (Erev) was maintained within the passive range (0–1 V vs SHE) to minimize corrosion. PDP and 60-day immersion tests confirmed passivity with 0.95). At a 1:1 Fe(III)/Fe(II) ratio, temperature variation from 25 to 95°C has little impact on E₍rev₎, which remains stable at 0.65–0.68 V vs SHE. In contrast, increasing the Fe(III)/Fe(II) ratio markedly raises E₍rev₎ from 0.60 V to 0.86 V. Despite these shifts, E₍rev₎ stays within the passive region, providing anodic protection and minimizing crevice and pitting risks.
- 19 November 2024
- Published by Springer Nature
- p. 557-559
Uniform and Localized Corrosion Behavior of 2205 Duplex Stainless Steel for Hydrometallurgical Applications: A Statistical Analysis
- 19 November 2024
- Published by Springer Nature
- p. 557-559
Uniform and Localized Corrosion Behavior of 2205 Duplex Stainless Steel for Hydrometallurgical Applications: A Statistical Analysis