Zachary Hansen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zachary Hansen has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Binh Tran
Department of Cellular and Molecular Medicine, College of Medicine, University of Arizona, Tucson, AZ 85721, USA
1 shared publication - Camila Grubb
Arizona Center for Accelerated Biomedical Innovation, University of Arizona, Tucson, AZ 85724, USA
1 shared publication - Chris Hedgecoke
Department of Biomedical Engineering, College of Engineering, University of Arizona, Tucson, AZ 85721, USA
1 shared publication - Ethan Ross
Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, AZ 85721, USA
1 shared publication - Farah Alqaraghuli
Department of Chemical Engineering, College of Engineering, University of Arizona, Tucson, AZ 85721, USA
1 shared publication - Greyson St Pierre
Department of Chemical Engineering, College of Engineering, University of Arizona, Tucson, AZ 85721, USA
1 shared publication
Latest Publications
- Open Access
- 19 November 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (11) , 1163
Around-Body Versus On-Body Motion Sensing: A Comparison of Efficacy Across a Range of Body Movements and Scales
Motion is vital for life. Currently, the clinical assessment of motion abnormalities is largely qualitative. We previously developed methods to quantitatively assess motion using visual detection systems (around-body) and stretchable electronic sensors (on-body). Here we compare the efficacy of these methods across predefined motions, hypothesizing that the around-body system detects motion with similar accuracy as on-body sensors. Six human volunteers performed six defined motions covering three excursion lengths, small, medium, and large, which were analyzed via both around-body visual marker detection (MoCa version 1.0) and on-body stretchable electronic sensors (BioStamp version 1.0). Data from each system was compared as to the extent of trackability and comparative efficacy between systems. Both systems successfully detected motions, allowing quantitative analysis. Angular displacement between systems had the highest agreement efficiency for the bicep curl and body lean motion, with 73.24% and 65.35%, respectively. The finger pinch motion had an agreement efficiency of 36.71% and chest abduction/adduction had 45.55%. Shoulder abduction/adduction and shoulder flexion/extension motions had the lowest agreement efficiencies with 24.49% and 26.28%, respectively. MoCa was comparable to BioStamp in terms of angular displacement, though velocity and linear speed output could benefit from additional processing. Our findings demonstrate comparable efficacy for non-contact motion detection to that of on-body sensor detection, and offers insight as to the best system selection for specific clinical uses based on the use-case of the desired motion being analyzed.
- 19 November 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (11) , 1163
Open AccessAround-Body Versus On-Body Motion Sensing: A Comparison of Efficacy Across a Range of Body Movements and Scales
Motion is vital for life. Currently, the clinical assessment of motion abnormalities is largely qualitative. We previously developed methods to quantitatively assess motion using visual detection systems (around-body) and stretchable electronic sensors (on-body). Here we compare the efficacy of these methods across predefined motions, hypothesizing that the around-body system detects motion with similar accuracy as on-body sensors. Six human volunteers performed six defined motions covering three excursion lengths, small, medium, and large, which were analyzed via both around-body visual marker detection (MoCa version 1.0) and on-body stretchable electronic sensors (BioStamp version 1.0). Data from each system was compared as to the extent of trackability and comparative efficacy between systems. Both systems successfully detected motions, allowing quantitative analysis. Angular displacement between systems had the highest agreement efficiency for the bicep curl and body lean motion, with 73.24% and 65.35%, respectively. The finger pinch motion had an agreement efficiency of 36.71% and chest abduction/adduction had 45.55%. Shoulder abduction/adduction and shoulder flexion/extension motions had the lowest agreement efficiencies with 24.49% and 26.28%, respectively. MoCa was comparable to BioStamp in terms of angular displacement, though velocity and linear speed output could benefit from additional processing. Our findings demonstrate comparable efficacy for non-contact motion detection to that of on-body sensor detection, and offers insight as to the best system selection for specific clinical uses based on the use-case of the desired motion being analyzed.