Yanhui Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yanhui Wang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Chenwei Peng
Department of Building Science, Tsinghua University, Beijing 100084, China
3 shared publications - Jiewen Deng
Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
3 shared publications - Hui Zhang
Department of Building Science, Tsinghua University, Beijing 100084, China
2 shared publications - Qingpeng Wei
Department of Building Science, Tsinghua University, Beijing 100084, China
2 shared publications - Yangyang Su
Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
2 shared publications - Donglin Xie
Department of Landscape Architecture, School of Architecture, Tsinghua University, Beijing 100084, China
1 shared publication
Latest Publications
- Open Access
- 4 July 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (13) , 6173
Research on the Configurations and Control Methods of a Hybrid System of Air-Source Heat Pumps and Gas Boilers for Space Heating: Simulation and Comparative Analysis
This study analyzes the configurations and control strategies of hybrid heating systems of air-source heat pumps (ASHPs) and gas boilers for space heating in different climatic regions in China, with the aim of improving the comprehensive energy efficiency. Parallel and series hybrid modes were proposed, and simulation analysis was conducted to analyze the energy performance, energy costs, and CO2 emissions of different hybrid systems. The results show that the supply water temperatures of ASHPs in series mode are lower than that of ASHPs in parallel mode; thus, the COP of ASHPs in series mode reached 2.73 and was higher than the COP of ASHPs in parallel mode with a value of 2.65. Then, the optimal intermediate temperatures of hybrid system in series mode were analyzed, so as to guide the system control. The results show that compared with series mode with a fixed 50% load distribution, the operational costs and CO2 emissions were reduced by 10.0% and 10.4% in Harbin, reduced by 6.4% and 8.3% in Beijing, and reduced by 10.0% and 15.1% in Wuhan. Additionally, the optimal intermediate temperature was affected by the building load ratio, supply water temperature, ambient air temperature, and the electricity–gas price ratio. The series-hybrid ASHP and gas boiler system achieves remarkable energy and cost savings across different climatic conditions, providing a scientific basis for promoting low-carbon heating solutions.
- 4 July 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (13) , 6173
Open AccessResearch on the Configurations and Control Methods of a Hybrid System of Air-Source Heat Pumps and Gas Boilers for Space Heating: Simulation and Comparative Analysis
This study analyzes the configurations and control strategies of hybrid heating systems of air-source heat pumps (ASHPs) and gas boilers for space heating in different climatic regions in China, with the aim of improving the comprehensive energy efficiency. Parallel and series hybrid modes were proposed, and simulation analysis was conducted to analyze the energy performance, energy costs, and CO2 emissions of different hybrid systems. The results show that the supply water temperatures of ASHPs in series mode are lower than that of ASHPs in parallel mode; thus, the COP of ASHPs in series mode reached 2.73 and was higher than the COP of ASHPs in parallel mode with a value of 2.65. Then, the optimal intermediate temperatures of hybrid system in series mode were analyzed, so as to guide the system control. The results show that compared with series mode with a fixed 50% load distribution, the operational costs and CO2 emissions were reduced by 10.0% and 10.4% in Harbin, reduced by 6.4% and 8.3% in Beijing, and reduced by 10.0% and 15.1% in Wuhan. Additionally, the optimal intermediate temperature was affected by the building load ratio, supply water temperature, ambient air temperature, and the electricity–gas price ratio. The series-hybrid ASHP and gas boiler system achieves remarkable energy and cost savings across different climatic conditions, providing a scientific basis for promoting low-carbon heating solutions.
- Open Access
Research on Configuration Optimization and Control Methods for Mid-Deep Geothermal Heat Pumps Coupled with Air-Source Heat Pump Systems for Space Heating in Residential Buildings
Mid-deep geothermal heat pump systems (MD-GHPs) feature high energy efficiency and low energy consumption, yet their promotion is restricted by high initial investment. While the initial investment of air-source heat pumps (ASHPs) is obviously lower, it also has a larger energy consumption. To address the complementary strengths and weaknesses of single-source heat pump systems, this paper puts forward an integrated system combining MD-GHPs and ASHPs, and the series mode was determined as the optimal integration approach for the hybrid system through comparative analysis. Simulation analysis was conducted to explore the adaptability of series mode, and numbers of mid-deep ground heat exchangers in nine cities across various climate regions were studied. The MD-GHP system is suitable for space heating in Xining and Xi’an, while ASHPs are suitable for space heating in Nanjing and Hangzhou. For intermediate resource areas like Urumqi and Tsingdao, the series mode achieves the best economic benefits during the 24th year of operation.
Open AccessResearch on Configuration Optimization and Control Methods for Mid-Deep Geothermal Heat Pumps Coupled with Air-Source Heat Pump Systems for Space Heating in Residential Buildings
Mid-deep geothermal heat pump systems (MD-GHPs) feature high energy efficiency and low energy consumption, yet their promotion is restricted by high initial investment. While the initial investment of air-source heat pumps (ASHPs) is obviously lower, it also has a larger energy consumption. To address the complementary strengths and weaknesses of single-source heat pump systems, this paper puts forward an integrated system combining MD-GHPs and ASHPs, and the series mode was determined as the optimal integration approach for the hybrid system through comparative analysis. Simulation analysis was conducted to explore the adaptability of series mode, and numbers of mid-deep ground heat exchangers in nine cities across various climate regions were studied. The MD-GHP system is suitable for space heating in Xining and Xi’an, while ASHPs are suitable for space heating in Nanjing and Hangzhou. For intermediate resource areas like Urumqi and Tsingdao, the series mode achieves the best economic benefits during the 24th year of operation.
- Open Access
- 19 November 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (22) , 10097
How to Evaluate the Operating Performance of Mid-Deep Geothermal Heat Pump Systems (MD-GHPs): A Study on a Multistage Evaluation Index System
Mid-deep geothermal heat pump systems (MD-GHPs) use mid-deep borehole heat exchangers (MDBHEs) to extract heat from the geothermal energy at a depth of 2–3 km, and have been used for space heating in China over the last decade. This paper proposes a comprehensive and multilevel evaluation-index system to analyze and evaluate the energy performance of MD-GHPs. The multilevel evaluation index system consists of a target layer, a criterion layer, and an index layer, where the criterion layer is subdivided into six aspects and the index layer includes 26 specific indices, reflecting the geothermal resources, heat transfer performance of the MDBHEs, energy efficiency of the heat pump systems, building space heating demand, grid dynamic response capability, and energy-saving and economic benefits. Then, based on both expert survey results and case study data, the entropy weight method and the analytic hierarchy process are integrated to determine indicator weight coefficients among the multilevel evaluation indices, comprehensively considering both subjective and objective analyses. Furthermore, a fuzzy comprehensive evaluation model is conducted to integrate these weighted indices into a multi-criteria evaluation of MD-GHP performance. Finally, the proposed method was applied to evaluate the practical performance of four projects, returning scores of 61.56, 58.33, 72.73, and 78.41. These evaluations enable an overall assessment of the energy performance of MD-GHPs, reflecting the technical weaknesses and offering optimization guidance for system design and operation.
- 19 November 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (22) , 10097
Open AccessHow to Evaluate the Operating Performance of Mid-Deep Geothermal Heat Pump Systems (MD-GHPs): A Study on a Multistage Evaluation Index System
Mid-deep geothermal heat pump systems (MD-GHPs) use mid-deep borehole heat exchangers (MDBHEs) to extract heat from the geothermal energy at a depth of 2–3 km, and have been used for space heating in China over the last decade. This paper proposes a comprehensive and multilevel evaluation-index system to analyze and evaluate the energy performance of MD-GHPs. The multilevel evaluation index system consists of a target layer, a criterion layer, and an index layer, where the criterion layer is subdivided into six aspects and the index layer includes 26 specific indices, reflecting the geothermal resources, heat transfer performance of the MDBHEs, energy efficiency of the heat pump systems, building space heating demand, grid dynamic response capability, and energy-saving and economic benefits. Then, based on both expert survey results and case study data, the entropy weight method and the analytic hierarchy process are integrated to determine indicator weight coefficients among the multilevel evaluation indices, comprehensively considering both subjective and objective analyses. Furthermore, a fuzzy comprehensive evaluation model is conducted to integrate these weighted indices into a multi-criteria evaluation of MD-GHP performance. Finally, the proposed method was applied to evaluate the practical performance of four projects, returning scores of 61.56, 58.33, 72.73, and 78.41. These evaluations enable an overall assessment of the energy performance of MD-GHPs, reflecting the technical weaknesses and offering optimization guidance for system design and operation.