Yasmeen A. A. Hassan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yasmeen A. A. Hassan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Nermine Victor Fares
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Abbassia, Cairo 11566, Egypt
3 shared publications Lobna A. Hussein
2 shared publications- Miriam Farid Ayad
Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Ain Shams University, Cairo, Egypt
2 shared publications - Lobna A. Hussein
Ain Shams University
1 shared publication Miriam F. Ayad
1 shared publication- Sherif Okeil
Technische Universität Braunschweig, Institut für Partikeltechnik, Volkmaroder Str. 5, Braunschweig, Germany
1 shared publication
Latest Publications
- Open Access
- 10 March 2026
- Published by Elsevier in SSRN Electronic Journal
Comparative Optimization of LLE, SPE, and QuEChERS for the Simultaneous HPLC-DAD Determination of Multiclass Pesticides in Potatoes: Application to Dissipation and Processing Studies
The economic viability of Egyptian potato exports relies heavily on compliance with strict international regulations regarding pesticide residues. This study establishes a robust, sensitive, green, and cost-effective High-Performance Liquid Chromatographic method with Diode Array Detection to quantify six multiclass pesticide residues simultaneously: Thiamethoxam, Cymoxanil, Metalaxyl, Fludioxonil, Imazalil, and Famoxadone in potato matrix. To overcome matrix complexity, a comprehensive optimization of sample preparation was conducted, critically comparing Liquid-Liquid Extraction (LLE), QuEChERS, and Solid Phase Extraction. Results demonstrated that LLE, utilizing a dichloromethane: acetone (50: 50, v/v) mixture with salt-assisted partitioning (1.0 g anhydrous magnesium sulfate and 0.5 g sodium chloride), offered superior extraction efficiency (recoveries 75.84%–87.92%). A C18 column was used to resolve the analytes within 12 minutes, using an acetonitrile-water gradient. Method validation per SANTE and ICH guidelines exhibited high linearity (R2 >0.999), accuracy, and precision (mean recoveries 99.02%–100.67% with average %RSD < 1.22%). It was then successfully applied to market sample monitoring. Furthermore, a dissipation study indicated that the residues follow first-order degradation kinetics in field conditions. Additionally, the impact of household processing was evaluated, showing that boiling potatoes for 30 minutes effectively reduces residue concentrations below Maximum Residue Limits, ensuring consumer safety. This optimized method provides a reliable analytical tool for routine quality control in import-export surveillance. Additionally, the Analytical GREEnness with score 0.69 and Green Analytical Procedure Index metrics were used to evaluate the environmental impact of the proposed method.
- 10 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessComparative Optimization of LLE, SPE, and QuEChERS for the Simultaneous HPLC-DAD Determination of Multiclass Pesticides in Potatoes: Application to Dissipation and Processing Studies
The economic viability of Egyptian potato exports relies heavily on compliance with strict international regulations regarding pesticide residues. This study establishes a robust, sensitive, green, and cost-effective High-Performance Liquid Chromatographic method with Diode Array Detection to quantify six multiclass pesticide residues simultaneously: Thiamethoxam, Cymoxanil, Metalaxyl, Fludioxonil, Imazalil, and Famoxadone in potato matrix. To overcome matrix complexity, a comprehensive optimization of sample preparation was conducted, critically comparing Liquid-Liquid Extraction (LLE), QuEChERS, and Solid Phase Extraction. Results demonstrated that LLE, utilizing a dichloromethane: acetone (50: 50, v/v) mixture with salt-assisted partitioning (1.0 g anhydrous magnesium sulfate and 0.5 g sodium chloride), offered superior extraction efficiency (recoveries 75.84%–87.92%). A C18 column was used to resolve the analytes within 12 minutes, using an acetonitrile-water gradient. Method validation per SANTE and ICH guidelines exhibited high linearity (R2 >0.999), accuracy, and precision (mean recoveries 99.02%–100.67% with average %RSD < 1.22%). It was then successfully applied to market sample monitoring. Furthermore, a dissipation study indicated that the residues follow first-order degradation kinetics in field conditions. Additionally, the impact of household processing was evaluated, showing that boiling potatoes for 30 minutes effectively reduces residue concentrations below Maximum Residue Limits, ensuring consumer safety. This optimized method provides a reliable analytical tool for routine quality control in import-export surveillance. Additionally, the Analytical GREEnness with score 0.69 and Green Analytical Procedure Index metrics were used to evaluate the environmental impact of the proposed method.
- Open Access
- 23 November 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (12) , 246
Development of All-Solid-State Potentiometric Sensors for Monitoring Carbendazim Residues in Oranges: A Degradation Kinetics Investigation
Monitoring fungicide residues in orange fruits is vital, as fungicides for orange cultivation are increasingly used to prevent yield loss. At the same time, increasing restrictions are added by regulatory organizations. For facile on-site monitoring of the fungicide carbendazim (MBC), five ion-selective potentiometric sensors are proposed and compared. The first two sensors were prepared with a precipitation-based technique using molybdate (sensor 1) and tetraphenylborate (TPB) (sensor 2), respectively. Furthermore, two ionophore-based sensors were prepared using β-cyclodextrin as ionophore together with TPB (sensor 3) and tetrakis(4-chlorophenyl)borate (TpClPB) (sensor 4) as ion-exchanger. Further incorporation of multi-walled carbon nanotubes (MWCNTs) between the graphite rod and the sensing membrane of sensor 4 (sensor 5) further improved the stability and significantly lowered the limit of detection (LOD). Their performance was evaluated according to IUPAC recommendations, revealing linear response in the concentration range 1 × 10−4–1 × 10−2 M, 1 × 10−5–1 × 10−2 M, 1 × 10−5–1 × 10−3 M, 1 × 10−6–1 × 10−3 M, and 1 × 10−7–1 × 10−3 M with a Nernstian slope of 54.56, 55.48, 56.00, 56.85, and 57.34 mV/decade, respectively. The LOD values for the five sensors were found to be 7.92 × 10−5, 9.98 × 10−6, 9.72 × 10−6, 9.61 × 10−7, and 9.57 × 10−8 M, respectively. The developed potentiometric sensors were successfully applied to determine the residue and degradation rate of MBC in orange samples. After the researched fungicide was applied to the orange trees, the preharvest interval (PHI) could be calculated based on the MBC degradation kinetics determined in the tested orange samples.
- 23 November 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (12) , 246
Open AccessDevelopment of All-Solid-State Potentiometric Sensors for Monitoring Carbendazim Residues in Oranges: A Degradation Kinetics Investigation
Monitoring fungicide residues in orange fruits is vital, as fungicides for orange cultivation are increasingly used to prevent yield loss. At the same time, increasing restrictions are added by regulatory organizations. For facile on-site monitoring of the fungicide carbendazim (MBC), five ion-selective potentiometric sensors are proposed and compared. The first two sensors were prepared with a precipitation-based technique using molybdate (sensor 1) and tetraphenylborate (TPB) (sensor 2), respectively. Furthermore, two ionophore-based sensors were prepared using β-cyclodextrin as ionophore together with TPB (sensor 3) and tetrakis(4-chlorophenyl)borate (TpClPB) (sensor 4) as ion-exchanger. Further incorporation of multi-walled carbon nanotubes (MWCNTs) between the graphite rod and the sensing membrane of sensor 4 (sensor 5) further improved the stability and significantly lowered the limit of detection (LOD). Their performance was evaluated according to IUPAC recommendations, revealing linear response in the concentration range 1 × 10−4–1 × 10−2 M, 1 × 10−5–1 × 10−2 M, 1 × 10−5–1 × 10−3 M, 1 × 10−6–1 × 10−3 M, and 1 × 10−7–1 × 10−3 M with a Nernstian slope of 54.56, 55.48, 56.00, 56.85, and 57.34 mV/decade, respectively. The LOD values for the five sensors were found to be 7.92 × 10−5, 9.98 × 10−6, 9.72 × 10−6, 9.61 × 10−7, and 9.57 × 10−8 M, respectively. The developed potentiometric sensors were successfully applied to determine the residue and degradation rate of MBC in orange samples. After the researched fungicide was applied to the orange trees, the preharvest interval (PHI) could be calculated based on the MBC degradation kinetics determined in the tested orange samples.