Taylor Spangler
Research Subjects
Research Interests
Taylor Spangler has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Assaf Govari
Biosense Webster, Irvine, CA (A.G., A.A., K.O., T. Sharma, P.P., C.B., T.T., Q.C., W.M.).
2 shared publications - Christopher Beeckler
Biosense Webster, Irvine, CA (A.G., A.A., K.O., T. Sharma, P.P., C.B., T.T., Q.C., W.M.).
2 shared publications - Hiroshi Nakagawa
Department of Cardiovascular Medicine Cleveland Clinic Cleveland Ohio USA
2 shared publications - Tushar Sharma
Biosense Webster, Irvine, CA (A.G., A.A., K.O., T. Sharma, P.P., C.B., T.T., Q.C., W.M.).
2 shared publications - Andrea Natale
Texas Cardiac Arrhythmia Institute, St David's Medical Center , Austin, TX
1 shared publication - Andreas Altman
Biosense Webster, Irvine, CA (A.G., A.A., K.O., T. Sharma, P.P., C.B., T.T., Q.C., W.M.).
1 shared publication
Latest Publications
- Open Access
- 1 April 2026
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 19 (4) , e014473
Safety and Chronic Atrial Lesion Formation With a Large-Tip, Contact-Force-Sensing Multipolar Pulsed Field Ablation Catheter: Effect of Application Number in a Porcine Beating Heart Model
BACKGROUND: Integration of catheter–tissue contact force with pulsed field ablation (PFA) dosing is essential for achieving safe and durable lesion formation with contact force sensing catheters in ventricular models. However, data on the use of these catheters for atrial ablation remain limited. This study evaluated the procedural safety and 30-day lesion characteristics of atrial PFA delivered with the OMNYPULSE ablation catheter in a porcine model. METHODS: Twelve pigs were randomized to receive either 6 (×6 or Group A) or 12 (×12 or group B) PFA applications per ablation. Following 3-dimensional electroanatomic mapping, PFA was delivered to the right superior and inferior pulmonary veins, cavotricuspid isthmus, right atrial posterior wall, left atrial roof, and mitral annulus. Procedural safety was assessed acutely, and lesion characteristics were evaluated on 30-day histology. Maximum transmurality extent (MTE) was defined as >80% of the lesion span exhibiting continuous endocardial-to-epicardial fibrosis within representative histological sections. RESULTS: Adequate catheter–tissue contact was achieved during PFA delivery (contact force, 28±15 g). No acute procedural complications were observed. At 30 days, PVs and right atrial sites (ie, cavotricuspid isthmus and right atrial posterior wall) demonstrated near-complete MTE regardless of PFA dosing. In contrast, MTE was significantly lower at the mitral annulus and LA roof compared with other sites (44±30% and 21±26%, respectively; P <0.001). Increasing the number of PFA applications (×12) resulted in a remarkable improvement in MTE at these locations, with MTE increases of up to 68% compared with ×6 dosing at these sites. CONCLUSIONS: Atrial PFA using the OMNYPULSE catheter was feasible and safe in a porcine model. However, lesion transmurality varied by atrial location and was dose-dependent at select sites, underscoring the need for site-specific PFA dosing strategies. Further studies are warranted to define optimal PFA parameters for consistent atrial lesion formation.
- 1 April 2026
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 19 (4) , e014473
Open AccessSafety and Chronic Atrial Lesion Formation With a Large-Tip, Contact-Force-Sensing Multipolar Pulsed Field Ablation Catheter: Effect of Application Number in a Porcine Beating Heart Model
BACKGROUND: Integration of catheter–tissue contact force with pulsed field ablation (PFA) dosing is essential for achieving safe and durable lesion formation with contact force sensing catheters in ventricular models. However, data on the use of these catheters for atrial ablation remain limited. This study evaluated the procedural safety and 30-day lesion characteristics of atrial PFA delivered with the OMNYPULSE ablation catheter in a porcine model. METHODS: Twelve pigs were randomized to receive either 6 (×6 or Group A) or 12 (×12 or group B) PFA applications per ablation. Following 3-dimensional electroanatomic mapping, PFA was delivered to the right superior and inferior pulmonary veins, cavotricuspid isthmus, right atrial posterior wall, left atrial roof, and mitral annulus. Procedural safety was assessed acutely, and lesion characteristics were evaluated on 30-day histology. Maximum transmurality extent (MTE) was defined as >80% of the lesion span exhibiting continuous endocardial-to-epicardial fibrosis within representative histological sections. RESULTS: Adequate catheter–tissue contact was achieved during PFA delivery (contact force, 28±15 g). No acute procedural complications were observed. At 30 days, PVs and right atrial sites (ie, cavotricuspid isthmus and right atrial posterior wall) demonstrated near-complete MTE regardless of PFA dosing. In contrast, MTE was significantly lower at the mitral annulus and LA roof compared with other sites (44±30% and 21±26%, respectively; P <0.001). Increasing the number of PFA applications (×12) resulted in a remarkable improvement in MTE at these locations, with MTE increases of up to 68% compared with ×6 dosing at these sites. CONCLUSIONS: Atrial PFA using the OMNYPULSE catheter was feasible and safe in a porcine model. However, lesion transmurality varied by atrial location and was dose-dependent at select sites, underscoring the need for site-specific PFA dosing strategies. Further studies are warranted to define optimal PFA parameters for consistent atrial lesion formation.
- Open Access
- 1 December 2025
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 18 (12) , e013911
Real-Time Prediction of Irreversible Lesion Size During Pulsed Field Ablation: Prospective Validation of a Novel Ablation Index Based on Contact Force and Number of Applications in a Swine Beating Heart Model
BACKGROUND: In a previous study, on pulsed-field ablation (PFA) in the swine ventricle, we found that lesion depth was described (±1 mm accuracy) by a logarithmic function of contact force (CF) and the number of PFA pulses (PF-ablation index). This study was designed to validate prospectively whether the novel PF-ablation index would allow PFA lesions to be created at depths of 3.5, 4.5, 5.5, and 6.5 mm with high prediction accuracy in a swine-beating heart model. METHODS: A 7.5F catheter with a 3.5 mm ablation electrode and CF sensor (ThermoCool SmartTouch SF-Dual Energy) was connected to a PFA system (TRUPULSE 2). In 6 closed-chest swine, a biphasic PFA pulse was delivered between the ablation electrode and a skin patch at 123 separate ventricular sites at 5 different levels of CF (1) low (average CF: 4–15 g; median, 12 g; n=25), (2) moderate (16–30 g; median, 23 g; n=41); 3) high (31–45 g; median, 36 g; n=27), (4) very high (46–68 g; median, 52 g; n=18); or (5) no electrode contact, 1 to 2 mm from the endocardium (n=12). PFA application was terminated when the PF-ablation index reached a predicted lesion depth of 3.5 mm (27 sites), 4.5 mm (25 sites), 5.5 mm (29 sites), and 6.5 mm (30 sites). Swine were euthanized 2 hours after ablation. Lesion size was measured using triphenyl tetrazolium chloride staining. RESULTS: Predicted lesion depth by the PF-ablation index correlated well with actual lesion depthwith ±1.0 mm accuracy in 97/106 (92%) lesions and ±1.5 mm accuracy in all 106 lesions. There were no or poor relationships between intracardiac electrogram attenuation, impedance decrease, electrode temperature, and lesion size. No detectable lesions were created without electrode contact. CONCLUSIONS: A novel PF-ablation index incorporating CF and the number of PFA pulses provides high accuracy in predicting lesion depth in real-time. Intracardiac electrogram attenuation, impedance decrease, and electrode temperature are poor predictors of PFA lesion size.
- 1 December 2025
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 18 (12) , e013911
Open AccessReal-Time Prediction of Irreversible Lesion Size During Pulsed Field Ablation: Prospective Validation of a Novel Ablation Index Based on Contact Force and Number of Applications in a Swine Beating Heart Model
BACKGROUND: In a previous study, on pulsed-field ablation (PFA) in the swine ventricle, we found that lesion depth was described (±1 mm accuracy) by a logarithmic function of contact force (CF) and the number of PFA pulses (PF-ablation index). This study was designed to validate prospectively whether the novel PF-ablation index would allow PFA lesions to be created at depths of 3.5, 4.5, 5.5, and 6.5 mm with high prediction accuracy in a swine-beating heart model. METHODS: A 7.5F catheter with a 3.5 mm ablation electrode and CF sensor (ThermoCool SmartTouch SF-Dual Energy) was connected to a PFA system (TRUPULSE 2). In 6 closed-chest swine, a biphasic PFA pulse was delivered between the ablation electrode and a skin patch at 123 separate ventricular sites at 5 different levels of CF (1) low (average CF: 4–15 g; median, 12 g; n=25), (2) moderate (16–30 g; median, 23 g; n=41); 3) high (31–45 g; median, 36 g; n=27), (4) very high (46–68 g; median, 52 g; n=18); or (5) no electrode contact, 1 to 2 mm from the endocardium (n=12). PFA application was terminated when the PF-ablation index reached a predicted lesion depth of 3.5 mm (27 sites), 4.5 mm (25 sites), 5.5 mm (29 sites), and 6.5 mm (30 sites). Swine were euthanized 2 hours after ablation. Lesion size was measured using triphenyl tetrazolium chloride staining. RESULTS: Predicted lesion depth by the PF-ablation index correlated well with actual lesion depthwith ±1.0 mm accuracy in 97/106 (92%) lesions and ±1.5 mm accuracy in all 106 lesions. There were no or poor relationships between intracardiac electrogram attenuation, impedance decrease, electrode temperature, and lesion size. No detectable lesions were created without electrode contact. CONCLUSIONS: A novel PF-ablation index incorporating CF and the number of PFA pulses provides high accuracy in predicting lesion depth in real-time. Intracardiac electrogram attenuation, impedance decrease, and electrode temperature are poor predictors of PFA lesion size.
- Open Access
- 17 November 2024
- Published by Elsevier in American Journal of Transplantation
- Vol. 25 (4) , 734-743
A novel intravascular bioartificial pancreas device shows safety and islet functionality over 30 days in nondiabetic swine
- 17 November 2024
- Published by Elsevier in American Journal of Transplantation
- Vol. 25 (4) , 734-743
Open AccessA novel intravascular bioartificial pancreas device shows safety and islet functionality over 30 days in nondiabetic swine