YCYanis Chemli

Yanis Chemli

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yanis Chemli has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Validation of Cardiorespiratory‐Gated Proton Beam Delivery for Stereotactic Arrhythmia Radioablation

    by Jagdip Kang, Felicitas J. Bijari, Yanis Chemli, Yen‐Lin Chen, Helen Deng, Nicolas Depauw, Maeva Dhaynaut, Adriano Garonna, Hyeongseok Kim, Marina Macdonald‐Soccorso, et al.

    Aims: Stereotactic arrhythmia radioablation (STAR) is a promising noninvasive therapy for refractory ventricular tachycardia. Using scanned proton beams for STAR enables precisely focused, high doses of ionizing radiation. Effective mitigation of target motion is critical for safety but remains challenging due to the complex interplay between beam scanning and cardiorespiratory motion. We evaluated the safety and feasibility of accurately delivering gated scanned proton beams to a ventricular myocardial target and compared lesion outcomes of respiratory (single)‐ and cardiorespiratory (dual)‐gated proton beams. Methods: Six pigs (the first two used as a test of the protocol) underwent baseline CT for treatment planning with a single fractional dose of 35 Gy to a myocardial target in the left ventricular free wall. They were subsequently treated with either single‐ or dual‐gated delivery using scanned proton beams. Treatment response was evaluated by echocardiography, blood analysis and positron emission tomography (PET)‐CT at baseline and 14−15 weeks after irradiation. Lesions were assessed at termination, and tissues were harvested for histopathology. Results: Average target expansion for intrafractional motion was lower with dual compared to single gating (16%−23% vs. 48%−72%, N = 2 in each arm). The irradiated area was distinguishable in vivo on PET‐CT and ex vivo in necropsy at the expected location in all animals. Visual lesion transmurality was confirmed by histology. Lesion sizes were not far from the expected volumes in dual‐gated animals but were larger in single‐gated animals ( p = 0.3 for between‐group comparison, N = 2 in each arm). Conclusions: The results confirmed the feasibility of the workflow. Dual‐gated irradiation was associated with reduced radiation exposure of the myocardium outside the target volume, and with lesion sizes closer to those planned.

  • YRT-PET: An Open-Source GPU-Accelerated Image Reconstruction Engine for Positron Emission Tomography

    by Yassir Najmaoui, Yanis Chemli, Maxime Toussaint, Yoann Petibon, Baptiste Marty, Kathryn Fontaine, Jean-Dominique Gallezot, Gašper Razdevšek, Matic Orehar, Maeva Dhaynaut, et al.

    Image reconstruction for positron emission tomography (PET) requires an accurate model of the PET scanner geometry and degrading factors to produce high-quality and clinically meaningful images. It is typically implemented by scanner manufacturers, with proprietary software designed specifically for each scanner. This limits the ability to perform direct comparisons between scanners or to develop advanced image reconstruction algorithms. Open-source image reconstruction software can offer an alternative to manufacturer implementations, allowing more control and portability. Several existing software packages offer a wide range of features and interfaces, but there is still a need for an engine that simultaneously offers reusable code, fast implementation and convenient interfaces for interoperability and extensibility.


  • PET Mapping of Receptor Occupancy Using Joint Direct Parametric Reconstruction

    by Thibault Marin, Vasily Belov, Yanis Chemli, Jinsong Ouyang, Yassir Najmaoui, Georges El Fakhri, Sridhar Duvvuri, Philip Iredale, Nicolas J. Guehl, Marc D. Normandin, et al.

    Receptor occupancy (RO) studies using PET neuroimaging play a critical role in the development of drugs targeting the central nervous system (CNS). The conventional approach to estimate drug receptor occupancy consists in estimation of binding potential changes between two PET scans (baseline and post-drug injection). This estimation is typically performed separately for each scan by first reconstructing dynamic PET scan data before fitting a kinetic model to time activity curves. This approach fails to properly model the noise in PET measurements, resulting in poor RO estimates, especially in low receptor density regions. Objective: In this work, we evaluate a novel joint direct parametric reconstruction framework to directly estimate distributions of RO and other kinetic parameters in the brain from a pair of baseline and post-drug injection dynamic PET scans. Methods: The proposed method combines the use of regularization on RO maps with alternating optimization to enable estimation of occupancy even in low binding regions. Results: Simulation results demonstrate the quantitative improvement of this method over conventional approaches in terms of accuracy and precision of occupancy. The proposed method is also evaluated in preclinical in-vivo experiments using 11C-MK-6884 and a muscarinic acetylcholine receptor 4 positive allosteric modulator drug, showing improved estimation of receptor occupancy as compared to traditional estimators. Conclusion: The proposed joint direct estimation framework improves RO estimation compared to conventional methods, especially in intermediate to low-binding regions. Significance: This work could potentially facilitate the evaluation of new drug candidates targeting the CNS.


  • Effects of List-Mode-Based Intraframe Motion Correction in Dynamic Brain PET Imaging

    by Amal Tiss, Yanis Chemli, Nicolas Guehl, Thibault Marin, Keith Johnson, Georges El Fakhri, Jinsong Ouyang

    Motion is unavoidable in dynamic 18F-MK6240 Positron Emission Tomography (PET) imaging, especially in Alzheimer’s disease (AD) research requiring long scan duration. To understand how motion correction affects quantitative analysis, we investigated two approaches: II-MC, which corrects for both inter-frame and intra-frame motion, and IO-MC, which only corrects for inter-frame motion. These methods were applied to 83 scans from 34 subjects, and we calculated distribution volume ratios (DVR) using the multilinear reference tissue model with two parameters (MRTM2) in tau-rich brain regions. Most of the studies yielded similar DVR results for both II-MC and IO-MC. However, in one scan of an AD subject, the inferior temporal region showed 14% higher DVR with II-MC compared to IO-MC. This difference was reasonable given the AD diagnosis, although similar results were not observed in other regions. Although discrepancies between IO-MC and II-MC results were rare, they underscore the importance of incorporating intra-frame motion correction for more accurate and dependable PET quantitation, particularly in the context of dynamic imaging. These findings suggest that while the overall impact of intra-frame motion correction may be subtle, it can improve the reliability of longitudinal PET data, ultimately enhancing our understanding of tau protein distribution in AD pathology.


  • Simulation results for limited-angle ultra-high time-of-flight resolution PET system

    by T. Marin, Y. Zhuo, M. Orehar, G. Razdevšekc, R. Dolenec, I. Mounime, J. Alamo, J. M. Benlloch, Y. Chemli, J. M. Fernández-Tenllado, et al.

    Positron emission tomography (PET) has become standard practice in many clinical applications including oncology, cardiology and neurology. Recent developments in PET scanners have pushed the limits of these applications, thanks to long axial field of view scanners which can improve system sensitivity and the use of time-of-flight (TOF) information which can improve spatial resolution. However, the cost and space requirements for total-body PET systems has created a need for flexible, low-cost yet high-sensitivity systems with large axial field of view. Additionally, currently achievable TOF resolutions (around 200 ps for current clinical scanners) limit the gains in image resolution. In this work, we present the first reconstructions for a flexible two-panel ultra-high TOF resolution PET system expected to achieve 75 ps full-width at half maximum (FWHM). The scanner relies on pixelated L(Y)SO scintillators with novel detectors with dual readout measuring depth-of-interaction (DOI) information. The performance of the new system is demonstrated on Monte-Carlo simulations of an anthropomorphological numerical phantom reconstructed using a newly developed TOF+DOI-enabled reconstruction engine. The presented reconstructions exhibit high image quality, demonstrating the promise of the proposed PET system.