Omar Darwish
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Omar Darwish has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
- Radhouene Neji
School of Biomedical Engineering and Imaging Sciences King's College London London UK
4 shared publications - Ralph Sinkus
Université de Paris, Center for Research on Inflammation, UMR 1149 National Institute for Health and Medical Research (INSERM), Team “From micro to macro in cancer development” Paris France
4 shared publications - Anne-Sophie van Schelt
Research Department of Imaging Physics and Engineering, School of Biomedical Engineering and Imaging Sciences King's College London London UK
2 shared publications - Arnie Purushotham
School of Cancer and Pharmaceutical Sciences, King’s College London, London, United Kingdom
2 shared publications - Thomas Joseph Vogl
Center for Cancer Research, Medical University of Vienna, Vienna, Austria
2 shared publications - Vitali Koch
Clinic for Radiology and Nuclear Medicine, University Hospital, Goethe University Frankfurt, 60590 Frankfurt am Main, Germany
2 shared publications
Latest Publications
- Open Access
- 16 July 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (14) , 2233
Cardiovascular Magnetic Resonance Elastography: Current Evidence, Challenges, and Future Perspectives
Myocardial and aortic stiffness are increasingly recognized as clinically relevant biomarkers for cardiovascular disease, yet their noninvasive quantification remains challenging. Magnetic resonance elastography (MRE) has emerged as a promising technique for the spatial mapping of tissue biomechanics by visualizing and analyzing propagating shear waves. This narrative review summarizes the current state of cardiovascular MRE, spanning technical developments in wave generation (acoustic, electromagnetic, gravitational, and transducer-free approaches), pulse sequence design (echo-planar imaging, gradient-recalled echo, spiral, and free-breathing three-dimensional acquisitions), and inversion algorithms (local frequency estimation, direct inversion, finite element methods, and multifrequency elastography). We present evidence from phantom validation, animal models (myocardial infarction, hypertension, right ventricular hypertrophy), and human studies encompassing cardiac amyloidosis, hypertrophic cardiomyopathy, diastolic dysfunction, and abdominal aortic aneurysm. Additionally, we discuss current challenges, including waveguide effects, standardization needs, and clinical translation barriers, and highlight emerging solutions through artificial intelligence, multifrequency methods, and transducer-free cardiac MRE.
- 16 July 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (14) , 2233
Open AccessCardiovascular Magnetic Resonance Elastography: Current Evidence, Challenges, and Future Perspectives
Myocardial and aortic stiffness are increasingly recognized as clinically relevant biomarkers for cardiovascular disease, yet their noninvasive quantification remains challenging. Magnetic resonance elastography (MRE) has emerged as a promising technique for the spatial mapping of tissue biomechanics by visualizing and analyzing propagating shear waves. This narrative review summarizes the current state of cardiovascular MRE, spanning technical developments in wave generation (acoustic, electromagnetic, gravitational, and transducer-free approaches), pulse sequence design (echo-planar imaging, gradient-recalled echo, spiral, and free-breathing three-dimensional acquisitions), and inversion algorithms (local frequency estimation, direct inversion, finite element methods, and multifrequency elastography). We present evidence from phantom validation, animal models (myocardial infarction, hypertension, right ventricular hypertrophy), and human studies encompassing cardiac amyloidosis, hypertrophic cardiomyopathy, diastolic dysfunction, and abdominal aortic aneurysm. Additionally, we discuss current challenges, including waveguide effects, standardization needs, and clinical translation barriers, and highlight emerging solutions through artificial intelligence, multifrequency methods, and transducer-free cardiac MRE.
- Open Access
- 14 July 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (5) , 2292-2308
Combined ADC and T 2 Mapping in the Prostate Using a 3D Reduced FOV Sequence
Purpose: To develop a 3D reduced FOV sequence for combined ADC and T 2 mapping in the prostate in a single scan. Methods: A 3D ADC and T 2 mapping reduced FOV acquisition is enabled using T 2 and diffusion preparation modules with slab‐selective tip‐down pulses and magnitude stabilizer gradients. Imaging shots are followed by 2D phase navigators for phase correction of diffusion‐prepared shots and dummy RF pulses for T 2 ‐prepared shots, as well as a constant delay to maintain the steady state of the longitudinal magnetization. Mono‐exponential fitting is used for ADC and T 2 mapping. T 2 mapping accuracy was assessed in a phantom against a single‐echo spin‐echo reference. In vivo, the sequence was compared in the prostate of 11 healthy volunteers against a multi‐echo spin‐echo acquisition, as well as standard and reduced FOV (rFOV) single‐shot EPI (ssEPI). Results: In the phantom experiments, T 2 values were not significantly different from the reference single‐echo spin‐echo measurements. ADC values in vivo were not significantly different from those obtained using ssEPI. T 2 values in vivo showed a mean bias of −21.7 ms compared to those obtained using multi‐echo spin‐echo with the first echo discarded in the fitting. The proposed sequence achieved similar overall image quality scores to those of ssEPI and rFOV ssEPI, improved perceived distortion scores, but lower perceived SNR scores. Conclusion: The proposed approach enables 3D reduced FOV, single‐scan ADC, and T 2 mapping with mono‐exponential fitting in the prostate.
- 14 July 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (5) , 2292-2308
Open AccessCombined ADC and T 2 Mapping in the Prostate Using a 3D Reduced FOV Sequence
Purpose: To develop a 3D reduced FOV sequence for combined ADC and T 2 mapping in the prostate in a single scan. Methods: A 3D ADC and T 2 mapping reduced FOV acquisition is enabled using T 2 and diffusion preparation modules with slab‐selective tip‐down pulses and magnitude stabilizer gradients. Imaging shots are followed by 2D phase navigators for phase correction of diffusion‐prepared shots and dummy RF pulses for T 2 ‐prepared shots, as well as a constant delay to maintain the steady state of the longitudinal magnetization. Mono‐exponential fitting is used for ADC and T 2 mapping. T 2 mapping accuracy was assessed in a phantom against a single‐echo spin‐echo reference. In vivo, the sequence was compared in the prostate of 11 healthy volunteers against a multi‐echo spin‐echo acquisition, as well as standard and reduced FOV (rFOV) single‐shot EPI (ssEPI). Results: In the phantom experiments, T 2 values were not significantly different from the reference single‐echo spin‐echo measurements. ADC values in vivo were not significantly different from those obtained using ssEPI. T 2 values in vivo showed a mean bias of −21.7 ms compared to those obtained using multi‐echo spin‐echo with the first echo discarded in the fitting. The proposed sequence achieved similar overall image quality scores to those of ssEPI and rFOV ssEPI, improved perceived distortion scores, but lower perceived SNR scores. Conclusion: The proposed approach enables 3D reduced FOV, single‐scan ADC, and T 2 mapping with mono‐exponential fitting in the prostate.
- Open Access
- 17 June 2026
- Published by Taylor & Francis in Annals of Medicine
- Vol. 58 (1) , 2687212
Navigating the diagnostic ‘gray zone’: prospective evaluation of an integrated MRI-Biomarker model for renal allograft triage
A critical dilemma in post-transplant surveillance is determining when minor functional changes (subtle serum creatinine fluctuations or slow renal function decline) or ambiguous ultrasound findings (including mildly elevated resistive index or cortical echogenicity) warrant invasive biopsy and treatment modification. We aimed to develop a non-invasive integrated tool combining advanced diffusion MRI with functional biomarkers to stratify patients within this diagnostic gray zone. In this prospective study, 120 renal transplant recipients underwent multi-b-value diffusion-weighted imaging at 3.0 T within 48 h prior to an allograft biopsy. Quantitative parameters of six diffusion MRI models were extracted from renal cortex and medulla. Clinical indicators, including serum HCO3-, were recorded. To establish a clear endpoint, patients were categorized into a Treatment-Changed group (presence of actionable active pathology, requiring modified therapies) and a Treatment-Unchanged group (normal or solely chronic/non-reversible lesions). Multivariable logistic regression identified independent predictors. Diagnostic performance was assessed using area under the curve (AUC) using repeated stratified 5-fold cross validation with 10 repeats and bootstrap resampling. Kaplan–Meier analysis assessed the association between model-based risk and subsequent graft functional decline, defined as a 30% or greater decrease in estimated glomerular filtration rate (eGFR) from baseline. The cortical distributed diffusion coefficient (DDC) and serum HCO3-, emerged as independent predictors of treatment-changed group. The integrated model achieved an AUC of 0.941, significantly outperforming the standard clinical reference model (eGFR, proteinuria, and ultrasound; AUC 0.563). Net reclassification improvement (0.479) demonstrated the model correctly reclassified 45.6% of patients. Furthermore, model-derived high-risk status significantly predicted long-term graft functional decline (log-rank p = 0.005). This integrated multiparametric protocol provides promising preliminary decision support for renal allograft surveillance. By noninvasively identifying the potential presence of actionable active pathology, this preliminary model may help optimize biopsy referrals and stratify patients who potentially require treatment modification. However, given the single-centre design, external validation is required before clinical implementation.
- 17 June 2026
- Published by Taylor & Francis in Annals of Medicine
- Vol. 58 (1) , 2687212
Open AccessNavigating the diagnostic ‘gray zone’: prospective evaluation of an integrated MRI-Biomarker model for renal allograft triage
A critical dilemma in post-transplant surveillance is determining when minor functional changes (subtle serum creatinine fluctuations or slow renal function decline) or ambiguous ultrasound findings (including mildly elevated resistive index or cortical echogenicity) warrant invasive biopsy and treatment modification. We aimed to develop a non-invasive integrated tool combining advanced diffusion MRI with functional biomarkers to stratify patients within this diagnostic gray zone. In this prospective study, 120 renal transplant recipients underwent multi-b-value diffusion-weighted imaging at 3.0 T within 48 h prior to an allograft biopsy. Quantitative parameters of six diffusion MRI models were extracted from renal cortex and medulla. Clinical indicators, including serum HCO3-, were recorded. To establish a clear endpoint, patients were categorized into a Treatment-Changed group (presence of actionable active pathology, requiring modified therapies) and a Treatment-Unchanged group (normal or solely chronic/non-reversible lesions). Multivariable logistic regression identified independent predictors. Diagnostic performance was assessed using area under the curve (AUC) using repeated stratified 5-fold cross validation with 10 repeats and bootstrap resampling. Kaplan–Meier analysis assessed the association between model-based risk and subsequent graft functional decline, defined as a 30% or greater decrease in estimated glomerular filtration rate (eGFR) from baseline. The cortical distributed diffusion coefficient (DDC) and serum HCO3-, emerged as independent predictors of treatment-changed group. The integrated model achieved an AUC of 0.941, significantly outperforming the standard clinical reference model (eGFR, proteinuria, and ultrasound; AUC 0.563). Net reclassification improvement (0.479) demonstrated the model correctly reclassified 45.6% of patients. Furthermore, model-derived high-risk status significantly predicted long-term graft functional decline (log-rank p = 0.005). This integrated multiparametric protocol provides promising preliminary decision support for renal allograft surveillance. By noninvasively identifying the potential presence of actionable active pathology, this preliminary model may help optimize biopsy referrals and stratify patients who potentially require treatment modification. However, given the single-centre design, external validation is required before clinical implementation.
- Open Access
- 19 April 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (2) , 682-697
Single‐Breathhold 3D MR Elastography in the Liver, With Simultaneous R2* and PDFF Mapping
Purpose: To develop a sequence for the rapid acquisition of MR elastography (MRE) parameters in 3D, with simultaneous measurement of proton‐density fat fraction (PDFF) and R 2 * for multiparametric assessment of liver disease. Methods: The proposed sequence uses an interleaved motion‐encoding scheme to acquire 3D volumes of all motion encodings and wave offsets from a single series of readouts with constant repetition time. This leads to a highly time‐efficient acquisition, which together with incoherent k‐space undersampling permits all MRE data to be acquired in a single breathhold. The undersampled volumes are reconstructed using compressed sensing with model‐based temporal regularisation. The sequence can be combined with a multi‐echo readout to allow 3D PDFF and R 2 * maps to be reconstructed from the reference volume of the MRE acquisition. Validation was performed in phantoms and in eight healthy volunteers. Results: Phantom measurements of all viscoelastic parameters, PDFF, and R 2 * corresponded closely with reference measurements. Average liver tissue parameter values acquired with the combined MRE, PDFF and R 2 * sequence at 3 T were 1.36 0.15 m/s for shear‐wave speed, 1.78 0.41 kPa for the magnitude of the complex shear modulus, 0.70 0.16 kPa for the loss modulus, 3.6% 1.0% for PDFF, and 46.9 7.3 s −1 for R 2 *. Conclusion: Single‐breathhold 3D MRE in the liver was achieved with a novel acquisition ordering. The sequence offers 3D elastograms from a 16‐s breathhold, or 3D elastograms with co‐registered PDFF and R 2 * maps from a 21‐s breathhold.
- 19 April 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (2) , 682-697
Open AccessSingle‐Breathhold 3D MR Elastography in the Liver, With Simultaneous R2* and PDFF Mapping
Purpose: To develop a sequence for the rapid acquisition of MR elastography (MRE) parameters in 3D, with simultaneous measurement of proton‐density fat fraction (PDFF) and R 2 * for multiparametric assessment of liver disease. Methods: The proposed sequence uses an interleaved motion‐encoding scheme to acquire 3D volumes of all motion encodings and wave offsets from a single series of readouts with constant repetition time. This leads to a highly time‐efficient acquisition, which together with incoherent k‐space undersampling permits all MRE data to be acquired in a single breathhold. The undersampled volumes are reconstructed using compressed sensing with model‐based temporal regularisation. The sequence can be combined with a multi‐echo readout to allow 3D PDFF and R 2 * maps to be reconstructed from the reference volume of the MRE acquisition. Validation was performed in phantoms and in eight healthy volunteers. Results: Phantom measurements of all viscoelastic parameters, PDFF, and R 2 * corresponded closely with reference measurements. Average liver tissue parameter values acquired with the combined MRE, PDFF and R 2 * sequence at 3 T were 1.36 0.15 m/s for shear‐wave speed, 1.78 0.41 kPa for the magnitude of the complex shear modulus, 0.70 0.16 kPa for the loss modulus, 3.6% 1.0% for PDFF, and 46.9 7.3 s −1 for R 2 *. Conclusion: Single‐breathhold 3D MRE in the liver was achieved with a novel acquisition ordering. The sequence offers 3D elastograms from a 16‐s breathhold, or 3D elastograms with co‐registered PDFF and R 2 * maps from a 21‐s breathhold.
- Open Access
- 1 March 2025
- Published by Radiological Society of North America (RSNA) in Radiology: Imaging Cancer
- Vol. 7 (2) , e240138
Tumor Biomechanics Quantified Using MR Elastography to Predict Response to Neoadjuvant Chemotherapy in Individuals with Breast Cancer
Assessment of tumor biomechanics through MR elastography improved the identification of complete responders among individuals with breast cancer undergoing neoadjuvant chemotherapy.
- 1 March 2025
- Published by Radiological Society of North America (RSNA) in Radiology: Imaging Cancer
- Vol. 7 (2) , e240138
Open AccessTumor Biomechanics Quantified Using MR Elastography to Predict Response to Neoadjuvant Chemotherapy in Individuals with Breast Cancer
Assessment of tumor biomechanics through MR elastography improved the identification of complete responders among individuals with breast cancer undergoing neoadjuvant chemotherapy.
- Open Access
MR Elastography Using the Gravitational Transducer
MR elastography is a non-invasive imaging technique that provides quantitative maps of tissue biomechanical properties, i.e., elasticity and viscosity. Currently, hepatic MR elastography is deployed in the clinic to assess liver fibrosis in MAFLD patients. In addition, research has demonstrated MR elastography’s ability to non-invasively assess chronic liver disease and to characterize breast cancer lesions and brain tumors. MR elastography requires efficient mechanical wave generation and penetration, motion-sensitized MRI sequences, and MR elastography inversion algorithms to retrieve the biomechanical properties of the tissue. MR elastography promises to enable non-invasive and versatile assessment of tissue, leading to better diagnosis and staging of several clinical conditions.
Open AccessMR Elastography Using the Gravitational Transducer
MR elastography is a non-invasive imaging technique that provides quantitative maps of tissue biomechanical properties, i.e., elasticity and viscosity. Currently, hepatic MR elastography is deployed in the clinic to assess liver fibrosis in MAFLD patients. In addition, research has demonstrated MR elastography’s ability to non-invasively assess chronic liver disease and to characterize breast cancer lesions and brain tumors. MR elastography requires efficient mechanical wave generation and penetration, motion-sensitized MRI sequences, and MR elastography inversion algorithms to retrieve the biomechanical properties of the tissue. MR elastography promises to enable non-invasive and versatile assessment of tissue, leading to better diagnosis and staging of several clinical conditions.
- Open Access
- 25 November 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (4) , 1602-1614
3D MR elastography at 0. 55 T : Concomitant field effects and feasibility
Purpose: To demonstrate the feasibility of hepatic 3D MR elastography (MRE) at 0.55 T in healthy volunteers using Hadamard encoding and to study the effects of concomitant fields in the domain of MRE in general. Methods: Concomitant field effects in MRE are assessed using a Taylor series expansion and an encoding scheme is proposed to study the corresponding effects on 3D MRE at 0.55 T in numerical simulations and in phantom experiments. In addition, five healthy volunteers were enrolled and scanned at 60 Hz mechanical excitation with a Hadamard‐encoded 3D MRE sequence at 0.55 T and were also scanned with a reference 3D MRE sequence at 3 T for comparison. The retrieved biomechanical parameters were the magnitude of the complex shear modulus (| G *|), the shear wave speed (Cs), and the loss modulus ( G ″). Comparison of apparent SNR between 3 T and 0.55 T was performed. Results: Theoretical analysis, numerical simulations and phantom experiments demonstrated that the effects of concomitant fields in 3D MRE at 0.55 T are negligible. In the healthy volunteer experiments, the mean values of | G *|, Cs, and G″ in the liver were 2.1 ± 0.3 kPa, 1.5 ± 0.1 m/s, and 0.8 ± 0.1 kPa at 0.55 T, respectively, and 2.0 ± 0.2 kPa, 1.5 ± 0.1 m/s, and 0.9 ± 0.1 kPa at 3 T, respectively. Bland–Altman analysis demonstrated good agreement between the biomechanical parameters retrieved at 0.55 T and 3 T. A 2.1‐fold relative apparent SNR decrease was observed in 3D MRE at 0.55 T in comparison with 3 T. Conclusion: Hepatic 3D MRE is feasible at 0.55 T, showing promising initial results in healthy volunteers.
- 25 November 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (4) , 1602-1614
Open Access3D MR elastography at 0. 55 T : Concomitant field effects and feasibility
Purpose: To demonstrate the feasibility of hepatic 3D MR elastography (MRE) at 0.55 T in healthy volunteers using Hadamard encoding and to study the effects of concomitant fields in the domain of MRE in general. Methods: Concomitant field effects in MRE are assessed using a Taylor series expansion and an encoding scheme is proposed to study the corresponding effects on 3D MRE at 0.55 T in numerical simulations and in phantom experiments. In addition, five healthy volunteers were enrolled and scanned at 60 Hz mechanical excitation with a Hadamard‐encoded 3D MRE sequence at 0.55 T and were also scanned with a reference 3D MRE sequence at 3 T for comparison. The retrieved biomechanical parameters were the magnitude of the complex shear modulus (| G *|), the shear wave speed (Cs), and the loss modulus ( G ″). Comparison of apparent SNR between 3 T and 0.55 T was performed. Results: Theoretical analysis, numerical simulations and phantom experiments demonstrated that the effects of concomitant fields in 3D MRE at 0.55 T are negligible. In the healthy volunteer experiments, the mean values of | G *|, Cs, and G″ in the liver were 2.1 ± 0.3 kPa, 1.5 ± 0.1 m/s, and 0.8 ± 0.1 kPa at 0.55 T, respectively, and 2.0 ± 0.2 kPa, 1.5 ± 0.1 m/s, and 0.9 ± 0.1 kPa at 3 T, respectively. Bland–Altman analysis demonstrated good agreement between the biomechanical parameters retrieved at 0.55 T and 3 T. A 2.1‐fold relative apparent SNR decrease was observed in 3D MRE at 0.55 T in comparison with 3 T. Conclusion: Hepatic 3D MRE is feasible at 0.55 T, showing promising initial results in healthy volunteers.