Chenghao Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chenghao Li has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Chunwei Cai
School of New Energy, Harbin Institute of Technology, Weihai, China
5 shared publications - Shuai Wu
School of New Energy, Harbin Institute of Technology, Weihai, China
5 shared publications - Xichen Liu
School of New Energy, Harbin Institute of Technology, Weihai, China
4 shared publications - Jinpeng Yu
Qingdao University
2 shared publications Xiuyun Ren
College of New Energy, Harbin Institute of Technology-Weihai, Weihai, China
2 shared publicationsMingdong Qi
State Grid Ningbo Electric Power Supply Company, Ningbo, China
1 shared publication
Latest Publications
- 3 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 16591-16604
Failure Mechanisms of Four-Plate Seawater Capacitive Power Transfer: A Poynting Vector Perspective
Existing research indicates that conventional four-plate Capacitive Power Transfer (CPT) system can hardly realize power transmission when the plates are fully submerged in seawater. However, the root cause of this failure in power transmission has not been investigated currently, still relying on simulation and experimental results, leading puzzles for scholars. Therefore, this article attempts to elucidate the failure mechanisms from the perspective of electromagnetics (EM) theory. It reveals that the high conductivity of seawater leads to significant attenuation and a dominant real part in CPT near-field complex Poynting vector, preventing effective reactive power coupling crucial for CPT. Then, an equivalent circuit model of seawater CPT is developed based on Poynting's theorem, establishing a fundamental connection between EM phenomena and lumped circuit models. Finally, the significant influence of conductivity on CPT is proved by simulation in COMSOL and experiments in lab and actual ocean, validating the feasibility of the theoretical analysis.
- 3 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 16591-16604
Failure Mechanisms of Four-Plate Seawater Capacitive Power Transfer: A Poynting Vector Perspective
Existing research indicates that conventional four-plate Capacitive Power Transfer (CPT) system can hardly realize power transmission when the plates are fully submerged in seawater. However, the root cause of this failure in power transmission has not been investigated currently, still relying on simulation and experimental results, leading puzzles for scholars. Therefore, this article attempts to elucidate the failure mechanisms from the perspective of electromagnetics (EM) theory. It reveals that the high conductivity of seawater leads to significant attenuation and a dominant real part in CPT near-field complex Poynting vector, preventing effective reactive power coupling crucial for CPT. Then, an equivalent circuit model of seawater CPT is developed based on Poynting's theorem, establishing a fundamental connection between EM phenomena and lumped circuit models. Finally, the significant influence of conductivity on CPT is proved by simulation in COMSOL and experiments in lab and actual ocean, validating the feasibility of the theoretical analysis.
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (2) , 1526-1532
An Implementation Method of Capacitive Power Transfer in Seawater Environments With Single-Wire Connection Using Seawater Ionic Conduction Effect
The strong ionic conduction of seawater creates a quasielectrostatic shielding effect, leading to weak capacitive power transfer (CPT) with the mutual coupling between capacitors suppressed. To achieve undersea CPT, this letter proposes and introduces an implementation method using a single wire to connect two Y-type capacitors, thus constructing a dual-pathway system where seawater serves as second conductive channel. The single wire is designed to provide an additional conduction path for power loop, which guides current in the seawater to the receiver. The conductive principle of the method is first introduced, describing the power flow and the distribution of the displacement and conduction current. Then, a LC-CL compensated topology with single wire and Y-type capacitors is analyzed to obtain constant voltage output. Finally, an experimental prototype is built to verify the proposal. The results indicate the system can successfully transfer 2 kW with 91% dc-dc efficiency to the load.
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (2) , 1526-1532
An Implementation Method of Capacitive Power Transfer in Seawater Environments With Single-Wire Connection Using Seawater Ionic Conduction Effect
The strong ionic conduction of seawater creates a quasielectrostatic shielding effect, leading to weak capacitive power transfer (CPT) with the mutual coupling between capacitors suppressed. To achieve undersea CPT, this letter proposes and introduces an implementation method using a single wire to connect two Y-type capacitors, thus constructing a dual-pathway system where seawater serves as second conductive channel. The single wire is designed to provide an additional conduction path for power loop, which guides current in the seawater to the receiver. The conductive principle of the method is first introduced, describing the power flow and the distribution of the displacement and conduction current. Then, a LC-CL compensated topology with single wire and Y-type capacitors is analyzed to obtain constant voltage output. Finally, an experimental prototype is built to verify the proposal. The results indicate the system can successfully transfer 2 kW with 91% dc-dc efficiency to the load.
- 21 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (6) , 7603-7614
Modeling and Implementation of a Long-Distance Seawater Single-Wire CPT System for Underwater Sensor
A long-distance, strong-misalignment tolerance seawater capacitive power transfer system with two insulated electric-field couplers and single-wire for underwater sensors is proposed in this article, and it has the advantages of low cost, low weight and hard worn-out compared with traditional structure. First, quasi electric double layer theory for coupler in seawater is proposed, and seawater between two couplers can be considered as equipotential medium is demonstrated in detail. Second, model of seawater electric-field coupled channel is built. The feasibility of long distance and strong misalignment tolerance is proved. Then, double T-LCL compensation network is investigated and selected for constant output voltage, zero phase angle (ZPA), and antifrequency-offset. Experimental results in lab show that the system can deliver 732.1 W at a dc–dc efficiency of 89.2%. In actual ocean, the experimental transmission distance is 10 m, achieving 206.8 W power transmission and 83% efficiency, which verifies the proposed program is adapted to power supply of sensors in complex ocean environment and the advantages of long distance. This article is also accompanied by a video file demonstrating experiment in actual ocean.
- 21 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (6) , 7603-7614
Modeling and Implementation of a Long-Distance Seawater Single-Wire CPT System for Underwater Sensor
A long-distance, strong-misalignment tolerance seawater capacitive power transfer system with two insulated electric-field couplers and single-wire for underwater sensors is proposed in this article, and it has the advantages of low cost, low weight and hard worn-out compared with traditional structure. First, quasi electric double layer theory for coupler in seawater is proposed, and seawater between two couplers can be considered as equipotential medium is demonstrated in detail. Second, model of seawater electric-field coupled channel is built. The feasibility of long distance and strong misalignment tolerance is proved. Then, double T-LCL compensation network is investigated and selected for constant output voltage, zero phase angle (ZPA), and antifrequency-offset. Experimental results in lab show that the system can deliver 732.1 W at a dc–dc efficiency of 89.2%. In actual ocean, the experimental transmission distance is 10 m, achieving 206.8 W power transmission and 83% efficiency, which verifies the proposed program is adapted to power supply of sensors in complex ocean environment and the advantages of long distance. This article is also accompanied by a video file demonstrating experiment in actual ocean.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (3) , 4640-4651
Modeling and Analysis of Undersea Capacitive Power Transfer Based on Conduction Current in Seawater
The liquid environment and high conductivity of the seawater, which changes the characteristic of capacitive coupler compared to the air condition, are the difficulties to adoption of capacitive power transfer (CPT) technology for marine device. In this paper, a universal circuit model of the bipolar plate fully immersed into water environment is proposed and divided into three cases based on the conductivity, validating the conduction path dominates the capacitive coupling in seawater. Then, the theoretical model of undersea four-plates coupler immersed into seawater, which consists of four coupling capacitances between metal plate and seawater and six seawater resistances, is derived, analyzed and simulated. It well explains the reason of stable parameters of the coupler and power mainly flowing in receiving side since coupling object is seawater rather than plate. Later, a seawater capacitive power transfer (SCPT) system with Y-type capacitor and single wire is proposed for realizing efficient power transmission. Finally, a laboratory prototype is established and achieves stable 171W and 85% DC-DC efficiency with lower than 1% variation under random misalignment.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (3) , 4640-4651
Modeling and Analysis of Undersea Capacitive Power Transfer Based on Conduction Current in Seawater
The liquid environment and high conductivity of the seawater, which changes the characteristic of capacitive coupler compared to the air condition, are the difficulties to adoption of capacitive power transfer (CPT) technology for marine device. In this paper, a universal circuit model of the bipolar plate fully immersed into water environment is proposed and divided into three cases based on the conductivity, validating the conduction path dominates the capacitive coupling in seawater. Then, the theoretical model of undersea four-plates coupler immersed into seawater, which consists of four coupling capacitances between metal plate and seawater and six seawater resistances, is derived, analyzed and simulated. It well explains the reason of stable parameters of the coupler and power mainly flowing in receiving side since coupling object is seawater rather than plate. Later, a seawater capacitive power transfer (SCPT) system with Y-type capacitor and single wire is proposed for realizing efficient power transmission. Finally, a laboratory prototype is established and achieves stable 171W and 85% DC-DC efficiency with lower than 1% variation under random misalignment.
- 10 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (2) , 3726-3737
Modeling and Design of a Transcutaneous Resonant Capacitive Power Transfer Link for Biomedical Implants
This article proposes a transcutaneous resonant capacitive power transfer link for biomedical implants using parallel thin-film electrodes as coupling plates. First, the practical multilayer tissue circuit model is obtained by tissue dielectric properties and current path. Analysis is presented to identify the influencing factors of loss mechanisms on power transfer efficiency (PTE) and power delivered to the load (PDL). Then, an asymmetric insulation layer coupler is proposed to reduce losses. The parameters of this design are obtained from the finite-element method for maximum PTE and high PDL. Moreover, the safety assessment and power transfer strategies are performed according to the IEEE C95.1 guideline; 90.73 mW of PDL is safely received at 47.02% PTE. Finally, two sets of comparative experiments are conducted at 6.78-MHz operating frequency using pork as the medium, evaluating the performance of symmetric insulation layer (t2 = 0.015 mm) and asymmetric insulation layer coupler (t2 = 0.15 mm). The experimental results show good agreement with the analytical and simulation results; the asymmetric insulation layer compared with the symmetry insulation layer improves efficiency by 8.9%.
- 10 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (2) , 3726-3737
Modeling and Design of a Transcutaneous Resonant Capacitive Power Transfer Link for Biomedical Implants
This article proposes a transcutaneous resonant capacitive power transfer link for biomedical implants using parallel thin-film electrodes as coupling plates. First, the practical multilayer tissue circuit model is obtained by tissue dielectric properties and current path. Analysis is presented to identify the influencing factors of loss mechanisms on power transfer efficiency (PTE) and power delivered to the load (PDL). Then, an asymmetric insulation layer coupler is proposed to reduce losses. The parameters of this design are obtained from the finite-element method for maximum PTE and high PDL. Moreover, the safety assessment and power transfer strategies are performed according to the IEEE C95.1 guideline; 90.73 mW of PDL is safely received at 47.02% PTE. Finally, two sets of comparative experiments are conducted at 6.78-MHz operating frequency using pork as the medium, evaluating the performance of symmetric insulation layer (t2 = 0.015 mm) and asymmetric insulation layer coupler (t2 = 0.15 mm). The experimental results show good agreement with the analytical and simulation results; the asymmetric insulation layer compared with the symmetry insulation layer improves efficiency by 8.9%.