YKYoshiyuki Kondo

Yoshiyuki Kondo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yoshiyuki Kondo has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Hideya Ikemiya

    Kyushu University 744 Moto-oka Nishi-ku Fukuoka-shi 819-0395 Fukuoka Japan

    1 shared publication
  • Masanobu Kubota

    Kyushu University 744 Moto-oka Nishi-ku Fukuoka-shi 819-0395 Fukuoka Japan

    1 shared publication
  • 正員,フェロー

    Kyushu University 744 Moto-oka Nishi-ku Fukuoka-shi 819-0395 Fukuoka Japan

    1 shared publication
  • 池宮 秀也

    Kyushu University 744 Moto-oka Nishi-ku Fukuoka-shi 819-0395 Fukuoka Japan

    1 shared publication
  • , 九州大学大学院工学研究院

    Kyushu University 744 Moto-oka Nishi-ku Fukuoka-shi 819-0395 Fukuoka Japan

    1 shared publication
  • ,久保田祐信

    Kyushu University 744 Moto-oka Nishi-ku Fukuoka-shi 819-0395 Fukuoka Japan

    1 shared publication

Latest Publications

  • Open Access

    Effect of Loading Rate and Tempering Temperature on Fracture Toughness of Hydrogen-Charged Low Alloy Steel SCM440

    by 池宮 秀也, ,久保田祐信, ,近藤良之, Hideya Ikemiya, Masanobu Kubota, Yoshiyuki Kondo, 正員,フェロー, , 九州大学大学院工学研究院

    J - R curves under continuous hydrogen charge were obtained to evaluate the effect of absorbed hydrogen on fracture toughness of SCM440 low alloy steel. The effect of absorbed hydrogen, loading rate and tempering temperature were investigated. Five materials which were tempered at different temperature to change Vickers hardness were used. Continuous hydrogen charge, which isolated the crack tip from the electrolyte and kept the crack in dry condition, was conducted during the test. Material hardness and loading rate significantly affected J - R curves and JIC. Low loading rate and high hardness resulted in drastically decreased JIC. The materials which were tempered at 803K showed 90% reduction of JIC compared with that of uncharged specimen. The significant reduction was experienced in materials with Vickers hardness higher than 310. Quasi-cleavage fracture surface was predominantly observed in the tests which resulted in low JIC. It is indicated that the hardness of low alloy steel used as a structural material should be limited below 300 on the viewpoint of fracture toughness. This study showed that low loading test that lasts for eighty hours at least is necessary to assess the JIC of hydrogen charged material.