Jack Bardzil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jack Bardzil has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Philipp Kukura
University of Oxford
5 shared publications - Jan Christoph Thiele
University of Oxford
4 shared publications - Justin L. P. Benesch
Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, Oxford, UK
4 shared publications - Dan Loewenthal
University of Oxford
3 shared publications Jack S. Peters
Kavli Institute for NanoScience Discovery, University of Oxford, Oxford, United Kingdom
3 shared publications- Kishwar Iqbal
The Kavli Institute for Nanoscience Discovery, University of Oxford, Dorothy Crowfoot Hodgkin Building, South Parks Road, Oxford OX1 3QU, U.K.
2 shared publications
Latest Publications
- Open Access
Super-resolved mass photometry reveals the dissociation pathways of individual protein complexes
Mass photometry (MP) measures the mass of single unlabelled molecules as they adsorb to a glass surface, but conventional analysis captures each molecule only momentarily, as it binds, and neglects its subsequent fate. Here we correct for coverslip drift and use mass-dependent localisation precision to link successive events at one site to a single molecule and enables two workflows for studying protein assemblies. In tandem MP, matching each binding event with its outcomes yields a two-dimensional precursor-product spectrum that separates dissociation from unbinding, providing structural insights into the protein assemblies and the kinetics of subunit loss. By comparing citrate synthase homologues, we reveal distinct fingerprints and disassembly pathways among complexes of the same oligomeric state. In particle tracking, differential imaging allows for continuous recording of particle mass and position. By examining adeno-associated virus capsids, we recovered accurate masses, and reveals acid-induced disassembly and movement behaviour that depends on both viral and imaging surfaces. Our code is freely available and applies to data obtained on commercial instruments with minimal changes to experimental protocols, offering additional dimensions to MP analysis beyond the mass histogram to return time-resolved, single-molecule histories.
Open AccessSuper-resolved mass photometry reveals the dissociation pathways of individual protein complexes
Mass photometry (MP) measures the mass of single unlabelled molecules as they adsorb to a glass surface, but conventional analysis captures each molecule only momentarily, as it binds, and neglects its subsequent fate. Here we correct for coverslip drift and use mass-dependent localisation precision to link successive events at one site to a single molecule and enables two workflows for studying protein assemblies. In tandem MP, matching each binding event with its outcomes yields a two-dimensional precursor-product spectrum that separates dissociation from unbinding, providing structural insights into the protein assemblies and the kinetics of subunit loss. By comparing citrate synthase homologues, we reveal distinct fingerprints and disassembly pathways among complexes of the same oligomeric state. In particle tracking, differential imaging allows for continuous recording of particle mass and position. By examining adeno-associated virus capsids, we recovered accurate masses, and reveals acid-induced disassembly and movement behaviour that depends on both viral and imaging surfaces. Our code is freely available and applies to data obtained on commercial instruments with minimal changes to experimental protocols, offering additional dimensions to MP analysis beyond the mass histogram to return time-resolved, single-molecule histories.
- Open Access
- 26 October 2026
- Published by Springer Nature in Nature Methods
- Vol. 23 (11) , 2151-2154
Continuous mass photometry by single-molecule trapping
The dynamic choreography of biomolecular interactions underpins the processes of life, but its direct observation remains challenging. Here we introduce continuous mass photometry, enabling hour-long, mass-resolved observation of individual biomolecules tethered to supported lipid bilayers, their complexes and interactions, with up to sub-kilodalton mass precision and millisecond temporal resolution. Our approach represents a quantitative time-resolved single-molecule measurement modality for studying complex biomolecular mechanisms in action.
- 26 October 2026
- Published by Springer Nature in Nature Methods
- Vol. 23 (11) , 2151-2154
Open AccessContinuous mass photometry by single-molecule trapping
The dynamic choreography of biomolecular interactions underpins the processes of life, but its direct observation remains challenging. Here we introduce continuous mass photometry, enabling hour-long, mass-resolved observation of individual biomolecules tethered to supported lipid bilayers, their complexes and interactions, with up to sub-kilodalton mass precision and millisecond temporal resolution. Our approach represents a quantitative time-resolved single-molecule measurement modality for studying complex biomolecular mechanisms in action.
- Open Access
Continuous mass photometry by single molecule trapping
The dynamic choreography of biomolecular interactions underpins the processes of life, but its direct observation remains challenging. Here, we introduce confined diffusion mass photometry, enabling hour-long, mass-resolved observation of individual biomolecules, their complexes and interactions with up to sub-kDa mass precision and ms temporal resolution. Our approach represents a quantitative time-resolved single-molecule measurement modality for studying complex biomolecular mechanisms in action.
Open AccessContinuous mass photometry by single molecule trapping
The dynamic choreography of biomolecular interactions underpins the processes of life, but its direct observation remains challenging. Here, we introduce confined diffusion mass photometry, enabling hour-long, mass-resolved observation of individual biomolecules, their complexes and interactions with up to sub-kDa mass precision and ms temporal resolution. Our approach represents a quantitative time-resolved single-molecule measurement modality for studying complex biomolecular mechanisms in action.
- Open Access
Deep learning-based event classification of mass photometry data for optimal mass measurement at the single-molecule level
Mass photometry (MP) is a powerful technique for studying biomolecular structure, interactions, and dynamics in solution. It detects and quantifies small reflectivity changes at a glass-water interface during protein (un)binding, with signals typically averaged over 100 milliseconds. However, particle motion at the point of single-molecule measurement can compromise key metrics such as mass resolution, sensitivity, and concentration. We present a three-dimensional convolutional residual network trained via supervised learning to classify landing events based on their spatiotemporal dynamics. By analysing 3D event thumbnails, our method isolates optimal single-molecule measurements, eliminating cumulative histogram artifacts and improving resolving power by up to a factor of 2. Validated across diverse experimental datasets—including resolved and partially resolved samples, and varying masses, concentrations, and integration times—our approach delivers robust performance under (sub)optimal conditions. Our approach provides measurement-level data-driven feedback, facilitating high quality MP measurements in challenging scenarios.
Open AccessDeep learning-based event classification of mass photometry data for optimal mass measurement at the single-molecule level
Mass photometry (MP) is a powerful technique for studying biomolecular structure, interactions, and dynamics in solution. It detects and quantifies small reflectivity changes at a glass-water interface during protein (un)binding, with signals typically averaged over 100 milliseconds. However, particle motion at the point of single-molecule measurement can compromise key metrics such as mass resolution, sensitivity, and concentration. We present a three-dimensional convolutional residual network trained via supervised learning to classify landing events based on their spatiotemporal dynamics. By analysing 3D event thumbnails, our method isolates optimal single-molecule measurements, eliminating cumulative histogram artifacts and improving resolving power by up to a factor of 2. Validated across diverse experimental datasets—including resolved and partially resolved samples, and varying masses, concentrations, and integration times—our approach delivers robust performance under (sub)optimal conditions. Our approach provides measurement-level data-driven feedback, facilitating high quality MP measurements in challenging scenarios.
- Open Access
Best practice mass photometry: A guide to optimal single molecule mass measurement
Mass photometry (MP) has emerged as a powerful approach to study biomolecular structure, dynamics and interactions. The capabilities of the method ultimately hinge on the ability to accurately measure the tiny optical contrast generated by individual molecules landing at a glass-water interface, which enables mass-resolved quantification of biomolecular mixtures. Ideally, this capability is only limited by shot noise inherent to photon detection, but in practice depends on additional parameters and details of the assay. Here, we focus on the key parameters affecting MP performance, and present simple steps that can be taken to achieve optimal MP performance in terms of mass resolution, quantitative detection limit and analyte concentration range without compromising the ease and simplicity of the technique.
Open AccessBest practice mass photometry: A guide to optimal single molecule mass measurement
Mass photometry (MP) has emerged as a powerful approach to study biomolecular structure, dynamics and interactions. The capabilities of the method ultimately hinge on the ability to accurately measure the tiny optical contrast generated by individual molecules landing at a glass-water interface, which enables mass-resolved quantification of biomolecular mixtures. Ideally, this capability is only limited by shot noise inherent to photon detection, but in practice depends on additional parameters and details of the assay. Here, we focus on the key parameters affecting MP performance, and present simple steps that can be taken to achieve optimal MP performance in terms of mass resolution, quantitative detection limit and analyte concentration range without compromising the ease and simplicity of the technique.