Abdeslem Beldjilali has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Nadia Saidi-Amroun
Material Physics Laboratory, Physics Faculty, University of Sciences and Technology (USTHB), BP 32 El-Alia, Bab-Ezzouar, Algiers, Algeria
3 shared publications - Fella Salhi
University of Sciences and Technology Houari Boumediene (USTHB)
1 shared publication - M. Saidi
Material Physics Laboratory, University of Sciences and Technology (USTHB) Algiers, Algeria
1 shared publication Mahdi Mansour
Materials Physics Laboratory Physics Faculty University of Sciences and Technology (USTHB) BP 32 El Alia, Bab Ezzouar 16111 Algiers Algeria
1 shared publicationMohamed Saidi
Materials Physics Laboratory Physics Faculty University of Sciences and Technology (USTHB) BP 32 El Alia, Bab Ezzouar 16111 Algiers Algeria
1 shared publication- Sarah Mouaci
Department of Materials and Components, University of Science and Technology Houari Boumediene (USTHB), BP 32 El Alia, Bab Ezzouar 16111, Algiers, Algeria
1 shared publication
Latest Publications
- 4 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 2443-2450
Investigation of Early Effects of Moderate Warm-Ups on Transformer Oils: Electric and Spectroscopic Analysis
This paper is devoted to studying, under in-service conditions, the probable effects induced by moderate heating on the electrical behavior of transformer oil. The experimental tools used are the Polarization and Depolarization Currents technique (PDC) and the FTIR spectroscopy. The aim is to highlight and understand how the insulating oil is affected by the frequent warm-ups into in service power transformer. The experiments, carried out under DC voltages and room temperature, are conducted on two kinds of oil samples: The first are virgin and they were not submitted to any thermal treatment or electrical stresses. Samples of the second family were subjected, before each measurement, to a specific heating at 75 °C during one hour. The PDC technique allows qualitative evidence (under DC electric fields and in a rest situation) the electrostatic effect of the moderate thermal heating. The measurements indicate a fully space charge conduction mechanism for the previously heated oil, while the conduction measured in the unheated oil does not follow any specific mechanism. After being supplemented by the FTIR spectroscopy, the electrical current features are interpreted as a trapping/de-trapping processes that are respectively correlated to the dehydrogenation/reticulation phenomena in transformer oil.
- 4 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 2443-2450
Investigation of Early Effects of Moderate Warm-Ups on Transformer Oils: Electric and Spectroscopic Analysis
This paper is devoted to studying, under in-service conditions, the probable effects induced by moderate heating on the electrical behavior of transformer oil. The experimental tools used are the Polarization and Depolarization Currents technique (PDC) and the FTIR spectroscopy. The aim is to highlight and understand how the insulating oil is affected by the frequent warm-ups into in service power transformer. The experiments, carried out under DC voltages and room temperature, are conducted on two kinds of oil samples: The first are virgin and they were not submitted to any thermal treatment or electrical stresses. Samples of the second family were subjected, before each measurement, to a specific heating at 75 °C during one hour. The PDC technique allows qualitative evidence (under DC electric fields and in a rest situation) the electrostatic effect of the moderate thermal heating. The measurements indicate a fully space charge conduction mechanism for the previously heated oil, while the conduction measured in the unheated oil does not follow any specific mechanism. After being supplemented by the FTIR spectroscopy, the electrical current features are interpreted as a trapping/de-trapping processes that are respectively correlated to the dehydrogenation/reticulation phenomena in transformer oil.
- Open Access
- 1 March 2019
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 13 (2) , 272-278
Effect of electrodes material on transient currents in dielectric liquid
In this study, results of polarisation and depolarisation currents measured on an insulating liquid are presented. The goal is to contribute to a better understanding of mechanisms occurring at the metal–liquid contact. Electrodes of different metallic nature are associated with the same mineral oil, the metal / liquid / metal structure is submitted to DC voltages and the transient current is recorded with a high sensitive electrometer. The current versus time feature shows that the conduction process is in good compliance with the metal work function rather than with its electric conductivity. The current versus field characteristics indicate a predominance of the ohmic behaviour for the low fields. The space charge limited conduction regime appears as soon as the electrical constraint exceeds ∼1 MV/m, which corresponds to 10% of the breakdown voltage. Schottky injection is suspected to occur from the metal into the liquid since the applied fields are uniform and non‐extremely intensified.
- 1 March 2019
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 13 (2) , 272-278
Open AccessEffect of electrodes material on transient currents in dielectric liquid
In this study, results of polarisation and depolarisation currents measured on an insulating liquid are presented. The goal is to contribute to a better understanding of mechanisms occurring at the metal–liquid contact. Electrodes of different metallic nature are associated with the same mineral oil, the metal / liquid / metal structure is submitted to DC voltages and the transient current is recorded with a high sensitive electrometer. The current versus time feature shows that the conduction process is in good compliance with the metal work function rather than with its electric conductivity. The current versus field characteristics indicate a predominance of the ohmic behaviour for the low fields. The space charge limited conduction regime appears as soon as the electrical constraint exceeds ∼1 MV/m, which corresponds to 10% of the breakdown voltage. Schottky injection is suspected to occur from the metal into the liquid since the applied fields are uniform and non‐extremely intensified.
- 7 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 23 (1) , 573-585
Space charge modeling in polymers: review of external applied constraints effects
The purpose of this work is to describe, with numerical simulation, the space charge behavior in polymeric materials. Particular intent is accorded to the variation of the thermo-electrical constraints. The simulation is performed for a range of the electric field from 10 to 110 MV/m and the space charge behavior was described at various temperatures: 0, 27, 60 and 100 ° C. In general, the numerical results show a predominance of the temperature effect, vs. the electric field, on the space charge behavior. The dynamic of the electrical charges is different under 100 ° C, a forehead is observed on their distribution in the sample. Strong electric field enhancements are remarked in the dielectric, they exceed 38% of the applied field under 100 ° C. Only 1.3% of augmentations are observed under room temperature even with higher applied field of 110 MV/m. Both experimental and theoretical Current-Field characteristics, plotted in log-log scale, show linear behavior with slopes greater than one. The different values of slope indicate space charge limited conduction; a change is remarked at 40 MV/m which can defines the beginning of the high fields regime in the case of the studied polymer (Polyethylene Naphthalate).
- 7 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 23 (1) , 573-585
Space charge modeling in polymers: review of external applied constraints effects
The purpose of this work is to describe, with numerical simulation, the space charge behavior in polymeric materials. Particular intent is accorded to the variation of the thermo-electrical constraints. The simulation is performed for a range of the electric field from 10 to 110 MV/m and the space charge behavior was described at various temperatures: 0, 27, 60 and 100 ° C. In general, the numerical results show a predominance of the temperature effect, vs. the electric field, on the space charge behavior. The dynamic of the electrical charges is different under 100 ° C, a forehead is observed on their distribution in the sample. Strong electric field enhancements are remarked in the dielectric, they exceed 38% of the applied field under 100 ° C. Only 1.3% of augmentations are observed under room temperature even with higher applied field of 110 MV/m. Both experimental and theoretical Current-Field characteristics, plotted in log-log scale, show linear behavior with slopes greater than one. The different values of slope indicate space charge limited conduction; a change is remarked at 40 MV/m which can defines the beginning of the high fields regime in the case of the studied polymer (Polyethylene Naphthalate).