Bhavana Kanwar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bhavana Kanwar has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Swatantra Pratap Singh
Indian Institute of Technology Bombay
5 shared publications - Amritanshu Shriwastav
Indian Institute of Technology Bombay
1 shared publication Azhan Ahmad
Environmental Science and Engineering Department, Indian Institute of Technology Bombay, Mumbai, 400076, India
1 shared publication- Lokesh P. Padhye
Stony Brook University
1 shared publication Mitil Koli
Indian Institute of Technology Bombay
1 shared publication- Najmul Haque Barbhuiya
Environmental Science and Engineering Department (ESED)
1 shared publication
Latest Publications
- 29 August 2026
- Published by American Chemical Society (ACS) in ACS ES&T Engineering
- Vol. 6 (10) , 2824-2835
Electrochemical Degradation of PFOA Using Graphite-Sheet Electrodes: Kinetics and Mechanisms
Per- and polyfluoroalkyl substances (PFAS) are persistent, bioaccumulative, and toxic contaminants characterized by highly stable fluorinated alkyl chains. Due to their chemical resilience, PFAS are frequently detected in both influents and effluents of conventional wastewater treatment plants, where they undergo minimal to no removal. Electrooxidation offers a promising, chemical-free approach for PFAS remediation, but it typically relies on expensive, high-performance electrodes such as boron-doped diamond (BDD) or titanium-based materials, limiting scalability and practical deployment. This study establishes the use of low-cost, unmodified, flexible graphite sheet electrodes as anodes for the electrochemical degradation of perfluorooctanoic acid (PFOA). The degradation efficiency was assessed under varying conditions, including initial PFOA concentrations (5–1,000 μg·L–1), current densities (2.5–12.5 mA.cm–2), pH (3–9), electrolyte concentrations (0–0.05 M NaCl), and the presence of reactive radical species. Under optimized conditions (0.05 M NaCl, 10 mA.cm–2, pH ≈ 6), ∼99% PFOA degradation was achieved within 90 min at an initial concentration of 10 μg·L–1, with a corresponding energy consumption of 16.09 kWh.m–3 per order. Hydroxyl radicals and chlorine-based reactive species were identified as key contributors to the degradation mechanism. However, degradation efficiency was inhibited in the presence of a complex wastewater matrix, consistent with the known limitations of radical-mediated processes. Liquid chromatography–mass spectrometry (LC-MS) analysis of the 90 min sample revealed the formation of intermediate degradation products, including shorter-chain perfluoroalkyl carboxylic acids such as perfluoroheptanoic acid (PFHpA), perfluorohexanoic acid (PFHxA), perfluoropentanoic acid (PFPeA), and perfluorobutanoic acid (PFBA). Overall, the electrochemical oxidation approach demonstrated in this study offers a promising, economically attractive alternative for the degradation of PFAS in contaminated groundwater and wastewater.
- 29 August 2026
- Published by American Chemical Society (ACS) in ACS ES&T Engineering
- Vol. 6 (10) , 2824-2835
Electrochemical Degradation of PFOA Using Graphite-Sheet Electrodes: Kinetics and Mechanisms
Per- and polyfluoroalkyl substances (PFAS) are persistent, bioaccumulative, and toxic contaminants characterized by highly stable fluorinated alkyl chains. Due to their chemical resilience, PFAS are frequently detected in both influents and effluents of conventional wastewater treatment plants, where they undergo minimal to no removal. Electrooxidation offers a promising, chemical-free approach for PFAS remediation, but it typically relies on expensive, high-performance electrodes such as boron-doped diamond (BDD) or titanium-based materials, limiting scalability and practical deployment. This study establishes the use of low-cost, unmodified, flexible graphite sheet electrodes as anodes for the electrochemical degradation of perfluorooctanoic acid (PFOA). The degradation efficiency was assessed under varying conditions, including initial PFOA concentrations (5–1,000 μg·L–1), current densities (2.5–12.5 mA.cm–2), pH (3–9), electrolyte concentrations (0–0.05 M NaCl), and the presence of reactive radical species. Under optimized conditions (0.05 M NaCl, 10 mA.cm–2, pH ≈ 6), ∼99% PFOA degradation was achieved within 90 min at an initial concentration of 10 μg·L–1, with a corresponding energy consumption of 16.09 kWh.m–3 per order. Hydroxyl radicals and chlorine-based reactive species were identified as key contributors to the degradation mechanism. However, degradation efficiency was inhibited in the presence of a complex wastewater matrix, consistent with the known limitations of radical-mediated processes. Liquid chromatography–mass spectrometry (LC-MS) analysis of the 90 min sample revealed the formation of intermediate degradation products, including shorter-chain perfluoroalkyl carboxylic acids such as perfluoroheptanoic acid (PFHpA), perfluorohexanoic acid (PFHxA), perfluoropentanoic acid (PFPeA), and perfluorobutanoic acid (PFBA). Overall, the electrochemical oxidation approach demonstrated in this study offers a promising, economically attractive alternative for the degradation of PFAS in contaminated groundwater and wastewater.
- 19 January 2026
- Published by Elsevier in Environmental Research
- Vol. 293, 123807
Microbial fuel cell powered Fenton degradation of ciprofloxacin from wastewater employing MIL-88B(Fe)-MOF-laser-induced graphene cathode
- 19 January 2026
- Published by Elsevier in Environmental Research
- Vol. 293, 123807
Microbial fuel cell powered Fenton degradation of ciprofloxacin from wastewater employing MIL-88B(Fe)-MOF-laser-induced graphene cathode
- 16 December 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (51) , 24492-24501
Reusable Laser-Induced Graphene Catalytic Filters for Pollutant Removal
- 16 December 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (51) , 24492-24501
Reusable Laser-Induced Graphene Catalytic Filters for Pollutant Removal
- Open Access
- 4 December 2024
- Published by Springer Nature in Research Square
Antibiotic amoxicillin degradation by electrochemical oxidation process: Effects of process parameters and degradation pathway at environmentally relevant concentrations
Amoxicillin (AMX) is a common antibiotic used in both human and veterinary medicine in order to both cure and avoid bacterial infections. Traces of AMX have been found in ground and surface water, urban effluents, water, and wastewater treatment facilities due to its widespread use. The level of hazard and disposal of this class of micropollutants is the reason for concern. Advanced technology is required since conventional wastewater treatment plants are ineffective at eliminating these emerging contaminants. Electrochemical oxidation is a promising method of treating wastewater, which uses electrogenerated radicals to mineralize organic pollutants. This work investigated the detailed process mechanism for AMX degradation utilizing a low-cost, thin, flexible graphite sheet with lower AMX concentrations, initial pH value, voltage, electrolyte concentration, and wastewater matrix. The degradation of AMX by in-situ generated hydroxyl radicals is a function of applied voltage and follows pseudo-first-order reaction kinetics. The removal efficiencies of AMX have been achieved up to 99% within 3 hours of reaction time. Moreover, intermediate by-products have been identified using liquid chromatography-mass spectrometry, and a plausible pathway has been proposed. This study could serve as a process reference for controlling AMX wastewater contamination via the electrochemical oxidation technique.
- 4 December 2024
- Published by Springer Nature in Research Square
Open AccessAntibiotic amoxicillin degradation by electrochemical oxidation process: Effects of process parameters and degradation pathway at environmentally relevant concentrations
Amoxicillin (AMX) is a common antibiotic used in both human and veterinary medicine in order to both cure and avoid bacterial infections. Traces of AMX have been found in ground and surface water, urban effluents, water, and wastewater treatment facilities due to its widespread use. The level of hazard and disposal of this class of micropollutants is the reason for concern. Advanced technology is required since conventional wastewater treatment plants are ineffective at eliminating these emerging contaminants. Electrochemical oxidation is a promising method of treating wastewater, which uses electrogenerated radicals to mineralize organic pollutants. This work investigated the detailed process mechanism for AMX degradation utilizing a low-cost, thin, flexible graphite sheet with lower AMX concentrations, initial pH value, voltage, electrolyte concentration, and wastewater matrix. The degradation of AMX by in-situ generated hydroxyl radicals is a function of applied voltage and follows pseudo-first-order reaction kinetics. The removal efficiencies of AMX have been achieved up to 99% within 3 hours of reaction time. Moreover, intermediate by-products have been identified using liquid chromatography-mass spectrometry, and a plausible pathway has been proposed. This study could serve as a process reference for controlling AMX wastewater contamination via the electrochemical oxidation technique.