Mario Leyba
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mario Leyba has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Carl R. Doerhoff
Capital Region Medical Center, Jefferson City, MO
1 shared publication - Eric J. Mallico
Novant Health Bariatric Solutions-Salisbury, Salisbury, NC
1 shared publication - John G. Linn
Northshore University Health System, Evanston, USA
1 shared publication - Karl A. LeBlanc
Our Lady of the Lake Physician Group, 7777 Hennessy Blvd., Suite 612, Baton Rouge, LA, 70808, USA
1 shared publication - Matthew I. Goldblatt
Department of Surgery, Division of Minimally Invasive Gastrointestinal Surgery, Medical College of Wisconsin, Milwaukee, WI
1 shared publication - Matthew Reynolds
HCA Florida Healthcare, Largo, FL
1 shared publication
Latest Publications
- Open Access
- 16 October 2024
- Published by Wolters Kluwer Health in Surgical Laparoscopy, Endoscopy & Percutaneous Techniques
- Vol. 34 (6) , 596-602
Ventral Hernia Repair With a Hybrid Absorbable-permanent Preperitoneal Mesh
Objective: To analyze device safety and clinical outcomes of ventral hernia repair with the GORE SYNECOR Preperitoneal Biomaterial (PRE device), a permanent high-strength mesh with bioabsorbable web scaffold technology. Materials and Methods: This multicenter retrospective review analyzed device/procedure endpoints and patient-reported outcomes in patients treated for hernia repair ≥1 year from study enrollment. Results: Included in this analysis were 148 patients with a mean age of 56 years; 66.2% met the Ventral Hernia Working Group grade 2 classification. Median hernia size was 30.0 cm2 and 58.8% of patients had an incisional hernia. Repairs were primarily a robotic (53.4%) or open approach (41.9%). All meshes were placed extraperitoneal. Procedure-related adverse events within 30 days occurred in 13 (8.8%) patients and included 7 (4.8%) patients with surgical site infection, 2 (1.4%) with surgical site occurrence (SSO), 4 (2.7%) requiring readmission, and 3 (2.0%) who had reoperation. The rate of SSO events requiring procedural intervention was 2.7% (4 patients) through 30 days and 3.4% (5 patients) at 12 months. The rate of procedure-related surgical site infection remained at 4.8% through 12 months (no further reports after 30 d) and 3.4% for SSO (2 reports after 30 d). There were no site-reported clinically diagnosed hernia recurrences throughout the study. Median patient follow-up including in-person visit, physical examination, reported adverse event, explant, death, and questionnaire response was 28 months (n = 148). Median patient follow-up with patient questionnaire was 36 months (n = 88). Conclusions: Use of the PRE device, which incorporates the proven advantages of both an absorbable synthetic mesh and the long-term durability of a permanent macroporous mesh, is safe and effective in complex ventral hernia repairs. When used in the retromuscular space, the combination of these 2 materials had lower wound complications and recurrence rates than either type of material alone.
- 16 October 2024
- Published by Wolters Kluwer Health in Surgical Laparoscopy, Endoscopy & Percutaneous Techniques
- Vol. 34 (6) , 596-602
Open AccessVentral Hernia Repair With a Hybrid Absorbable-permanent Preperitoneal Mesh
Objective: To analyze device safety and clinical outcomes of ventral hernia repair with the GORE SYNECOR Preperitoneal Biomaterial (PRE device), a permanent high-strength mesh with bioabsorbable web scaffold technology. Materials and Methods: This multicenter retrospective review analyzed device/procedure endpoints and patient-reported outcomes in patients treated for hernia repair ≥1 year from study enrollment. Results: Included in this analysis were 148 patients with a mean age of 56 years; 66.2% met the Ventral Hernia Working Group grade 2 classification. Median hernia size was 30.0 cm2 and 58.8% of patients had an incisional hernia. Repairs were primarily a robotic (53.4%) or open approach (41.9%). All meshes were placed extraperitoneal. Procedure-related adverse events within 30 days occurred in 13 (8.8%) patients and included 7 (4.8%) patients with surgical site infection, 2 (1.4%) with surgical site occurrence (SSO), 4 (2.7%) requiring readmission, and 3 (2.0%) who had reoperation. The rate of SSO events requiring procedural intervention was 2.7% (4 patients) through 30 days and 3.4% (5 patients) at 12 months. The rate of procedure-related surgical site infection remained at 4.8% through 12 months (no further reports after 30 d) and 3.4% for SSO (2 reports after 30 d). There were no site-reported clinically diagnosed hernia recurrences throughout the study. Median patient follow-up including in-person visit, physical examination, reported adverse event, explant, death, and questionnaire response was 28 months (n = 148). Median patient follow-up with patient questionnaire was 36 months (n = 88). Conclusions: Use of the PRE device, which incorporates the proven advantages of both an absorbable synthetic mesh and the long-term durability of a permanent macroporous mesh, is safe and effective in complex ventral hernia repairs. When used in the retromuscular space, the combination of these 2 materials had lower wound complications and recurrence rates than either type of material alone.