Nhat Minh Pham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nhat Minh Pham has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Lan Anh Nguyen
Hanoi Medical University
2 shared publicationsManh Hung Pham
Department of Cardiology, Hanoi Medical University–Hanoi Medical University Hospital, Vietnam
2 shared publications- Arne F. Jacob
Institute of High-Frequency Technology, Hamburg University of Technology, Hamburg, Germany
1 shared publication - Dinh Huynh Linh
Vietnam National Heart Institute, Bach Mai Hospital, Hanoi 11520, Vietnam
1 shared publication Hoai Nguyen Thi Thu
Bach Mai Hospital
1 shared publication- Hoai Thi Thu Nguyen
Department of Internal Medicine, Faculty of Medicine, VNU University of Medicine and Pharmacy, Hanoi, Vietnam; Vietnam National Heart Institute, Bach Mai Hospital, Hanoi, Vietnam
1 shared publication
Latest Publications
- Open Access
- 11 August 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (16) , 6219
Post-TAVR Neo-Sinus Geometry and Impaired Ventricular Recovery Are Associated with Early Leaflet Thrombosis: First MDCT Insights from Vietnam
Background/Objectives: Leaflet thrombosis after transcatheter aortic valve replacement (TAVR), typically identified as hypoattenuated leaflet thickening (HALT) on multidetector computed tomography (MDCT), is increasingly recognized as an early manifestation of bioprosthetic valve dysfunction. However, factors associated with early HALT in Southeast Asian populations remain poorly characterized. The objective of this study was to characterize MDCT features of leaflet thrombosis and identify factors independently associated with early HALT after TAVR. Methods: In this two-center observational study, patients undergoing MDCT 1–3 months after TAVR were evaluated. Leaflet thrombosis was defined as HALT. Leaflet involvement, thrombus severity, anatomical distribution, and post-implantation geometric parameters were analyzed. Multivariable logistic regression identified factors associated with early HALT. Results: Among 65 patients, HALT was detected in 30.8%, predominantly as subclinical leaflet thrombosis (29.2%), whereas clinical valve thrombosis was rare (1.5%). Most cases involved one or two leaflets, with preferential involvement of the non-coronary cusp. Patients with HALT showed greater increases in transvalvular peak gradients, and a peak gradient increase ≥10 mmHg was more frequent than in patients without HALT (30.0% vs. 4.4%; p = 0.008). Severe RCA ostial eccentricity (grade 3–4) combined with a neo-sinus–RCA distance > 13 mm was independently associated with HALT (adjusted OR 5.52; p = 0.006). Lack of left ventricular ejection fraction improvement after TAVR was also independently associated with HALT (adjusted OR 4.44; p = 0.018), though given the limited number of HALT events (n = 20), these multivariable associations should be regarded as exploratory and hypothesis-generating. Conclusions: Early post-TAVR leaflet thrombosis is common and predominantly subclinical. CT-derived neo-sinus geometry and impaired ventricular recovery were independently associated with HALT, supporting the hypothesis that altered neo-sinus washout contributes to thrombus formation.
- 11 August 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (16) , 6219
Open AccessPost-TAVR Neo-Sinus Geometry and Impaired Ventricular Recovery Are Associated with Early Leaflet Thrombosis: First MDCT Insights from Vietnam
Background/Objectives: Leaflet thrombosis after transcatheter aortic valve replacement (TAVR), typically identified as hypoattenuated leaflet thickening (HALT) on multidetector computed tomography (MDCT), is increasingly recognized as an early manifestation of bioprosthetic valve dysfunction. However, factors associated with early HALT in Southeast Asian populations remain poorly characterized. The objective of this study was to characterize MDCT features of leaflet thrombosis and identify factors independently associated with early HALT after TAVR. Methods: In this two-center observational study, patients undergoing MDCT 1–3 months after TAVR were evaluated. Leaflet thrombosis was defined as HALT. Leaflet involvement, thrombus severity, anatomical distribution, and post-implantation geometric parameters were analyzed. Multivariable logistic regression identified factors associated with early HALT. Results: Among 65 patients, HALT was detected in 30.8%, predominantly as subclinical leaflet thrombosis (29.2%), whereas clinical valve thrombosis was rare (1.5%). Most cases involved one or two leaflets, with preferential involvement of the non-coronary cusp. Patients with HALT showed greater increases in transvalvular peak gradients, and a peak gradient increase ≥10 mmHg was more frequent than in patients without HALT (30.0% vs. 4.4%; p = 0.008). Severe RCA ostial eccentricity (grade 3–4) combined with a neo-sinus–RCA distance > 13 mm was independently associated with HALT (adjusted OR 5.52; p = 0.006). Lack of left ventricular ejection fraction improvement after TAVR was also independently associated with HALT (adjusted OR 4.44; p = 0.018), though given the limited number of HALT events (n = 20), these multivariable associations should be regarded as exploratory and hypothesis-generating. Conclusions: Early post-TAVR leaflet thrombosis is common and predominantly subclinical. CT-derived neo-sinus geometry and impaired ventricular recovery were independently associated with HALT, supporting the hypothesis that altered neo-sinus washout contributes to thrombus formation.
- Open Access
- 20 November 2025
- Published by SAGE Publications in Journal of International Medical Research
- Vol. 53 (11)
Ten-year experience with transcatheter mitral valve repair using the MitraClip system in Vietnam: A multicenter observational study
Objectives: Numerous studies have demonstrated the safety and efficacy of percutaneous MitraClip transcatheter interventional therapy in treating mitral regurgitation. This study reports the largest series of outcomes in Vietnamese patients who underwent the MitraClip procedure. Methods and results: Between September 2014 and December 2024, 23 patients (20 males and 3 females; mean age, 66.3 ± 10.2 years) underwent the MitraClip procedure at five hospitals across Vietnam. Key findings included a high procedural success rate, with 91.3% of patients receiving successful implantations. Postprocedural complications were observed in 33.3% of patients. During the 30-day follow-up, two patients (9.5%) were readmitted; however, no mortality was reported. All patients achieved a mitral regurgitation grade of ≤2+, and 92.9% showed improvement to New York Heart Association Class I/II within 30 days postprocedure. Conclusions: Multicenter data from hospitals across Vietnam indicate that the MitraClip procedure is effective in reducing mitral regurgitation and demonstrate favorable short-term safety outcomes.
- 20 November 2025
- Published by SAGE Publications in Journal of International Medical Research
- Vol. 53 (11)
Open AccessTen-year experience with transcatheter mitral valve repair using the MitraClip system in Vietnam: A multicenter observational study
Objectives: Numerous studies have demonstrated the safety and efficacy of percutaneous MitraClip transcatheter interventional therapy in treating mitral regurgitation. This study reports the largest series of outcomes in Vietnamese patients who underwent the MitraClip procedure. Methods and results: Between September 2014 and December 2024, 23 patients (20 males and 3 females; mean age, 66.3 ± 10.2 years) underwent the MitraClip procedure at five hospitals across Vietnam. Key findings included a high procedural success rate, with 91.3% of patients receiving successful implantations. Postprocedural complications were observed in 33.3% of patients. During the 30-day follow-up, two patients (9.5%) were readmitted; however, no mortality was reported. All patients achieved a mitral regurgitation grade of ≤2+, and 92.9% showed improvement to New York Heart Association Class I/II within 30 days postprocedure. Conclusions: Multicenter data from hospitals across Vietnam indicate that the MitraClip procedure is effective in reducing mitral regurgitation and demonstrate favorable short-term safety outcomes.
- Open Access
- 29 November 2024
- Published by SAGE Publications in Journal of International Medical Research
- Vol. 52 (11)
Characterizing chest pain in patients with acute coronary syndrome at Vietnam National Heart Institute: a case-control study
Objective: This study aimed to distinguish chest pain characteristics between patients with and without acute coronary syndrome (ACS) at Vietnam National Heart Institute. Methods: A case-control study using a structured chest pain assessment questionnaire was performed to examine pain characteristics. Results: Smoking, a history of heart attack, and a family history of cardiovascular disease were associated with increased ACS-related chest pain risk. Patients without ACS more frequently reported left or central chest pain, mild discomfort, pain triggered by activity, and relief with rest or nitroglycerin. ACS-related chest pain was more often characterized by pain radiating to the back, a sensation of tightness or severe discomfort, gradual intensity increase, occurrence at rest or with minimal exertion, and accompanying sweating. No significant sex differences were found in ACS-related chest pain symptoms. Conclusions: Targeted assessment of chest pain features—such as pain radiation, pressure sensation, symptom escalation, duration, activity triggers, and relief factors—could improve public awareness and support the development of educational resources on ACS and non-ACS symptoms.
- 29 November 2024
- Published by SAGE Publications in Journal of International Medical Research
- Vol. 52 (11)
Open AccessCharacterizing chest pain in patients with acute coronary syndrome at Vietnam National Heart Institute: a case-control study
Objective: This study aimed to distinguish chest pain characteristics between patients with and without acute coronary syndrome (ACS) at Vietnam National Heart Institute. Methods: A case-control study using a structured chest pain assessment questionnaire was performed to examine pain characteristics. Results: Smoking, a history of heart attack, and a family history of cardiovascular disease were associated with increased ACS-related chest pain risk. Patients without ACS more frequently reported left or central chest pain, mild discomfort, pain triggered by activity, and relief with rest or nitroglycerin. ACS-related chest pain was more often characterized by pain radiating to the back, a sensation of tightness or severe discomfort, gradual intensity increase, occurrence at rest or with minimal exertion, and accompanying sweating. No significant sex differences were found in ACS-related chest pain symptoms. Conclusions: Targeted assessment of chest pain features—such as pain radiation, pressure sensation, symptom escalation, duration, activity triggers, and relief factors—could improve public awareness and support the development of educational resources on ACS and non-ACS symptoms.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 257-260
High-performance radar imaging with sparse receiver array
A sparse receiver array system based on a hybrid approach combining a two-stage-correlator with difference-pattern processing (DPP) is presented. With one sparse array and three dense arrays a thinning rate of more than 80% is demonstrated. The high resolution and low spurious signal generation of the two-stage-correlator are further improved by applying DPP with a suitable weighting factor. The performance of this approach is demonstrated by both simulation and measurements.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 257-260
High-performance radar imaging with sparse receiver array
A sparse receiver array system based on a hybrid approach combining a two-stage-correlator with difference-pattern processing (DPP) is presented. With one sparse array and three dense arrays a thinning rate of more than 80% is demonstrated. The high resolution and low spurious signal generation of the two-stage-correlator are further improved by applying DPP with a suitable weighting factor. The performance of this approach is demonstrated by both simulation and measurements.