HAHovakim A. Aleksanyan

Hovakim A. Aleksanyan

*This is an algorithmically generated author record based on publicly available information.

Hovakim A. Aleksanyan has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Surgical treatment of an extensive acetabular defect in a patient with aseptic instability of a total hip arthroplasty: a clinical case and updated literature review

    by N. V. Zagorodniy, A. G. Nazarenko, S. V. Kagramanov, O. A. Aleksanyan, G. A. Chragyan, I. V. Frolikov, M. R. Abdullin, Н. В. Загородний, А. Г. Назаренко, С. В. Каграманов, et al.

    The objective of this study was to demonstrate, using a clinical example, the possibility of one-stage revision hip arthroplasty with a custom 3D-printed acetabular implant for an extensive acetabular defect with pelvic discontinuity, and to review recent literature on this topic. We report a 45-year-old female patient with multiple prior hip surgeries (reconstructive procedures in childhood; primary and revision arthroplasties in 1991, 1998, 2001 and 2012) who presented in 2019 with aseptic instability of the right total hip arthroplasty and a Paprosky type IIIB acetabular defect. One-stage revision arthroplasty was performed using a custom triflange acetabular component designed from CT data and manufactured from titanium powder using direct metal laser sintering (DMLS). The Harris Hip Score improved from 21 points preoperatively to 82 points at 6 months; the WOMAC score decreased from 73 to 15 points over the same period. No early postoperative complications occurred; mild residual limp related to scarring and gluteal muscle atrophy persisted. An updated review of the 2018–2026 literature confirms that custom additively manufactured implants remain an effective option for restoring limb support and hip function in extensive acetabular defects and pelvic discontinuity, although dislocation, nerve injury and infection remain relevant risks requiring further refinement of planning, fixation and stability strategies.

  • Open Access

    Robotic Hip arthroplasty in patients with dysplastic coxarthrosis

    by Ilya V. Frolikov, Фроликов Илья Вадимович, Sergey V. Kagramanov, Каграманов Сергей Владимирович, Nikolay V. Zagorodniy, Загородний Николай Васильевич, Hamlet A. Chragyan, Чрагян Гамлет Ашотович, Hovakim A. Aleksanyan, Алексанян Оваким Аргамович, et al.

    Dysplastic coxarthrosis represents one of the most challenging issues in modern orthopedics, accounting for 48.4% of all coxarthrosis cases in patients under 50 years of age. Anatomical deformities in hip dysplasia create significant technical difficulties during arthroplasty, leading to a higher incidence of complications. The key problem of this pathology is the progressive degeneration of the joint: incongruence of the femoral head and acetabulum of the hip joint, which causes early wear of the articular surfaces , subluxation/dislocation of the hip, limb shortening, and compensatory postural disorders. The prevalence of hip dysplasia is 2%–3% among newborns, with 30% of patients with hip dysplasia developing secondary osteoarthritis by the age of 40, and, in the absence of positive response from conservative therapy, requiring total hip arthroplasty. Total hip arthroplasty for dysplastic coxarthrosis remains a technically complex operation due to pronounced anatomical changes: hypoplasia of the acetabulum, bone deficiency in various planes, a narrow femoral canal, and increased anteversion of the femur. Over the past two decades, there has been an evolution in computer technologies in total hip arthroplasty from simple navigation systems to advanced robotic platforms. For hip arthroplasty, modern robotic systems use 3D planning based on computed tomography data, which allows minimizing positioning errors of the cup to ≤1° and ≤1 mm, taking into account the patient’s individual anatomical features. The relevance of implementing robotic systems for patients with dysplastic coxarthrosis is confirmed by studies demonstrating a reduction in the incidence of dislocations in robot-assisted operations, as well as a decrease in the risk of aseptic instability, restoration of biomechanical parameters: offset, lower limb length, acetabular reaming while minimizing potential bone defects in the acetabulum for subsequent revision intervention.

  • Use of Modern Robotic Systems in Knee Arthroplasty

    by National Medical Research Center of Traumatology and Orthopedics named after N. N. Priorov, Israil M.–Kh. Gayrabekov, Sergey V. Kagramanov, Hovakim A. Aleksanyan, Nikolay V. Zagorodniy, Peoples Friendship University of Russia named after Patrice Lumumba, Mukhamed R. Khazhkasimov

    INTRODUCTION: In recent years, robot-assisted total knee replacement is gaining increasing significance due to its potential in improving clinical outcomes and reducing the risk of complications. The introduction of robotic systems (RSs) in surgical practice permitted to improve the accuracy of implant placement, which is of key significance for restoring the normal joint function. AIM: To analyze the use of modern RSs in the knee arthroplasty (KA) based of the available literature sources. MATERIALS AND METHODS: In the course of study, a search was conducted in the MEDLINE, CyberLeninka, Mendeley, Web of Science and EMBASE databases for clinical studies, review articles and meta-analyses that addressed the topic of total knee arthroplasty in humans using both conventional and robot-assisted methods. RSs provide support to surgeons in bone cutting and ensure continuous feedback during surgery permitting to achieve the optimal kinematics of the joint and soft tissue balance. Accurate information about position and movement of instruments minimizes the risk of implant malposition, which is a common cause of reoperations. Different RSs, such as Cuvis Joint™ and МАКО among others, offer unique advantages and functionalities, each having particular applications and limitations. CONCLUSION: The introduction of robot-assisted technologies in knee arthroplasty represents a significant progress in orthopedic surgery. Further research and accumulation of the clinical experience will help optimize application of these systems, which will probably lead to improvement of long-term treatment outcomes.


  • Open Access

    The use of an individual acetabular component for acetabular defect: a clinical case

    by Hovakim A. Aleksanyan, Hamlet A. Chragyan, Sergey V. Kagramanov, Ruslan A. Khanmuradov, Nikolay V. Zagorodniy, Алексанян Оваким Аргамович, Чрагян Гамлет Ашотович

    BACKGROUND: The incidence of total hip replacements is increasing every year. Acetabular defects are becoming more frequent, with Paprosky type IIIA and above becoming more common. Recently, customized 3D-printed constructs have been used to remodel severe defects. We wanted to demonstrate the possibility of treating a patient with a severe acetabular defect by performing a one-stage revision endoprosthesis using a customized design. CLINICAL CASES DESCRIPTION: A 69-year-old patient underwent primary total hip replacement of the right hip joint with a Biomet endoprosthesis for coxarthrosis in 2010. In 2011 on the left side with a Zimmer endoprosthesis. In 2013 revision endoprosthesis of the right hip joint due to instability was preformed. In the postoperative period, there were repeated dislocations with subsequent closed repositioning. In 2015, revision endoprosthetic replacement with a Burkh-Schneider antiprotrusion ring was done for recurrent dislocation. In november 2017, she was diagnosed with instability of the right total hip joint, for which she underwent revision hip replacement with a customized acetabular component. HHS score before revision arthroplasty was 18 points, 1 month after surgery 75 points, after 3 months 65, after 6 months 82, after 4 years 74. Quality of life was assessed using the WOMAC scale: 92 points before surgery, 38 points 1 month after surgery, 31 points in 3 months, 15 points in 6 months, and 35 points in 4 years. As of the last visit, the patient moves with a cane, and still has a limp due to scar remodeling and gluteal muscles atrophy. CONCLUSION: In case of severe acetabular defects, the use of individual components allows achieving reliable "implantbone" fixation, which leads to improved functional results. However, in chronic pelvic bone integrity defects, the use of an individual acetabular component does not always achieve reliable stabilization. All existing methods for solving this problem are currently ambiguous and require further improvement.

  • Open Access

    Early results of revision acetabular endoprosthetics using individual designs

    by Hovakim A. Aleksanyan, Hamlet A. Chragyan, Sergey V. Kagramanov, Artem V. Ivanov, Konstantin Yu. Ukolov, Egor V. Polevoy, Алексанян Оваким Аргамович, Чрагян Гамлет Ашотович

    BACKGROUND: 3D-printed implants are one of the options for acetabulum reconstruction. The popularity of this technique is increasing every year. AIM: To evaluate the early clinical, radiological and functional results of revision arthroplasty using individual acetabular components in patients with acetabulum bone defects. MATERIALS AND METHODS: Revision endoprosthetics was performed in 50 patients. There were 36 female and 14 male patients. The patients mean age was 60.413.4 (2389) years. According to the Paprosky classification, the defects in 1 case corresponded to type IIC, in 12 cases to type IIIA, in 37 cases to type IIIB, including 8 cases with violation of the acetabulum integrity. Hip joint function was assessed using the Harris Hip Score (HHS), pain severity using the Visual Analogue Scale (VAS), and social adjustment using the Western Ontario and McMaster Universities Arthritis Index (WOMAC). RESULTS: Significant improvement was obtained on all assessment scales. The HHS score improved on average from 33.6 to 87.1 points, the VAS scale from 78.1 to 4.7 points, and the WOMAC from 75.8 to 11.6 points. There were 8 cases (21%) with complications in total. In one case with a violation of the acetabulum integrity we observed migration of the sciatic bone from the lower flange of the construct. CONCLUSION: Thus, the results of the acetabulum reconstruction using individually fabricated acetabular components are promising.


  • Open Access

    Treatment of an extensive acetabular defect in a patient with aseptic instability of a total hip arthroplasty

    by Hovakim A. Aleksanyan, Hamlet A. Chragyan, Sergey V. Kagramanov, Nikolay V. Zagorodniy, Алексанян Оваким Аргамович, Чрагян Гамлет Ашотович

    The aim of the study is to demonstrate, using a clinical example, the possibility of treating a patient with a severe acetabular defect by performing a one-stage revision arthroplasty using an individual design. Materials and methods. A 45-year-old female patient was admitted with complaints of pain, limitation of movement in the right hip joint, and gait disturbance. From anamnesis at the age of 5 years, reconstructive operations of the hip joints were performed. In 1991, CITO performed primary total arthroplasty of the right hip joint with an endoprosthesis from ESKA Implants. In 1998, due to the instability of the acetabular component of the total endoprosthesis of the right hip joint, revision arthroplasty was performed, and the cup was placed with a cement fixation. In 2001, for left-sided dysplastic coxarthrosis, primary total arthroplasty of the left hip joint was performed. In 2012, due to the instability of the total endoprosthesis of the left hip joint, revision arthroplasty was performed using an ESI anti-protrusion ring (ENDOSERVICE) with a cement cup and a Zweimller-type femoral component; the femur defect was repaired using a fresh frozen cortical graft. In October 2019, instability of the total endoprosthesis of the right hip joint was revealed, for which revision endoprosthetics was performed using an individual acetabular component. Results. The HHS index before revision arthroplasty was 21 points, after 1 month after surgery 44 points, after 3 months after surgery 65, after 6 months 82. Quality of life was assessed according to the WOMAC scale: before surgery 73 points, after 1 month after surgery 54 points, after 3 months 31, after 6 months 15 points. At the time of the last consultation, the patient moves with a cane, lameness persists, associated with scar reconstruction and atrophy of the gluteal muscles. Conclusion. The use of individual structures allows to restore the support ability of the lower limb and the function of the hip joint in the case of an extensive defect of the pelvic bones of the pelvic discontinuity type.