Ilya V. Frolikov
Research Subjects
Ilya V. Frolikov has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Hamlet A. Chragyan
National medical research center for traumatology and orthopedics named after N.N. Priorov
2 shared publications - Hovakim A. Aleksanyan
N.N. Priorov National Medical Research Center of Traumatology and Orthopaedics
2 shared publications - Nikolay Vasilievich Zagorodniy
FSBI National Medical Research Center of Traumatology and Orthopedics named after N.N. Priorov" of the Ministry of Health of Russia
2 shared publications - Sergey V. Kagramanov
Priorov National Medical Research Center of Traumatology and Orthopedics
2 shared publications - Anton Gerasimovich Nazarenko
N.N. Priorov National Medical Research Center of Traumatology and Orthopaedics
1 shared publication - Giramutdin I. Esedov
Priorov National Medical Research Center of Traumatology and Orthopedics
1 shared publication
Latest Publications
- Open Access
- 12 September 2026
- Published by Arterialnaya Gipertenziya in Russian surgical journal
- Vol. 2 (3) , 268-277
Surgical treatment of an extensive acetabular defect in a patient with aseptic instability of a total hip arthroplasty: a clinical case and updated literature review
The objective of this study was to demonstrate, using a clinical example, the possibility of one-stage revision hip arthroplasty with a custom 3D-printed acetabular implant for an extensive acetabular defect with pelvic discontinuity, and to review recent literature on this topic. We report a 45-year-old female patient with multiple prior hip surgeries (reconstructive procedures in childhood; primary and revision arthroplasties in 1991, 1998, 2001 and 2012) who presented in 2019 with aseptic instability of the right total hip arthroplasty and a Paprosky type IIIB acetabular defect. One-stage revision arthroplasty was performed using a custom triflange acetabular component designed from CT data and manufactured from titanium powder using direct metal laser sintering (DMLS). The Harris Hip Score improved from 21 points preoperatively to 82 points at 6 months; the WOMAC score decreased from 73 to 15 points over the same period. No early postoperative complications occurred; mild residual limp related to scarring and gluteal muscle atrophy persisted. An updated review of the 2018–2026 literature confirms that custom additively manufactured implants remain an effective option for restoring limb support and hip function in extensive acetabular defects and pelvic discontinuity, although dislocation, nerve injury and infection remain relevant risks requiring further refinement of planning, fixation and stability strategies.
- 12 September 2026
- Published by Arterialnaya Gipertenziya in Russian surgical journal
- Vol. 2 (3) , 268-277
Open AccessSurgical treatment of an extensive acetabular defect in a patient with aseptic instability of a total hip arthroplasty: a clinical case and updated literature review
The objective of this study was to demonstrate, using a clinical example, the possibility of one-stage revision hip arthroplasty with a custom 3D-printed acetabular implant for an extensive acetabular defect with pelvic discontinuity, and to review recent literature on this topic. We report a 45-year-old female patient with multiple prior hip surgeries (reconstructive procedures in childhood; primary and revision arthroplasties in 1991, 1998, 2001 and 2012) who presented in 2019 with aseptic instability of the right total hip arthroplasty and a Paprosky type IIIB acetabular defect. One-stage revision arthroplasty was performed using a custom triflange acetabular component designed from CT data and manufactured from titanium powder using direct metal laser sintering (DMLS). The Harris Hip Score improved from 21 points preoperatively to 82 points at 6 months; the WOMAC score decreased from 73 to 15 points over the same period. No early postoperative complications occurred; mild residual limp related to scarring and gluteal muscle atrophy persisted. An updated review of the 2018–2026 literature confirms that custom additively manufactured implants remain an effective option for restoring limb support and hip function in extensive acetabular defects and pelvic discontinuity, although dislocation, nerve injury and infection remain relevant risks requiring further refinement of planning, fixation and stability strategies.
- Open Access
- 25 August 2026
- Published by ECO-Vector LLC (Publications) in N.N. Priorov Journal of Traumatology and Orthopedics
- Vol. 33 (3) , 704-714
Robotic Hip arthroplasty in patients with dysplastic coxarthrosis
Dysplastic coxarthrosis represents one of the most challenging issues in modern orthopedics, accounting for 48.4% of all coxarthrosis cases in patients under 50 years of age. Anatomical deformities in hip dysplasia create significant technical difficulties during arthroplasty, leading to a higher incidence of complications. The key problem of this pathology is the progressive degeneration of the joint: incongruence of the femoral head and acetabulum of the hip joint, which causes early wear of the articular surfaces , subluxation/dislocation of the hip, limb shortening, and compensatory postural disorders. The prevalence of hip dysplasia is 2%–3% among newborns, with 30% of patients with hip dysplasia developing secondary osteoarthritis by the age of 40, and, in the absence of positive response from conservative therapy, requiring total hip arthroplasty. Total hip arthroplasty for dysplastic coxarthrosis remains a technically complex operation due to pronounced anatomical changes: hypoplasia of the acetabulum, bone deficiency in various planes, a narrow femoral canal, and increased anteversion of the femur. Over the past two decades, there has been an evolution in computer technologies in total hip arthroplasty from simple navigation systems to advanced robotic platforms. For hip arthroplasty, modern robotic systems use 3D planning based on computed tomography data, which allows minimizing positioning errors of the cup to ≤1° and ≤1 mm, taking into account the patient’s individual anatomical features. The relevance of implementing robotic systems for patients with dysplastic coxarthrosis is confirmed by studies demonstrating a reduction in the incidence of dislocations in robot-assisted operations, as well as a decrease in the risk of aseptic instability, restoration of biomechanical parameters: offset, lower limb length, acetabular reaming while minimizing potential bone defects in the acetabulum for subsequent revision intervention.
- 25 August 2026
- Published by ECO-Vector LLC (Publications) in N.N. Priorov Journal of Traumatology and Orthopedics
- Vol. 33 (3) , 704-714
Open AccessRobotic Hip arthroplasty in patients with dysplastic coxarthrosis
Dysplastic coxarthrosis represents one of the most challenging issues in modern orthopedics, accounting for 48.4% of all coxarthrosis cases in patients under 50 years of age. Anatomical deformities in hip dysplasia create significant technical difficulties during arthroplasty, leading to a higher incidence of complications. The key problem of this pathology is the progressive degeneration of the joint: incongruence of the femoral head and acetabulum of the hip joint, which causes early wear of the articular surfaces , subluxation/dislocation of the hip, limb shortening, and compensatory postural disorders. The prevalence of hip dysplasia is 2%–3% among newborns, with 30% of patients with hip dysplasia developing secondary osteoarthritis by the age of 40, and, in the absence of positive response from conservative therapy, requiring total hip arthroplasty. Total hip arthroplasty for dysplastic coxarthrosis remains a technically complex operation due to pronounced anatomical changes: hypoplasia of the acetabulum, bone deficiency in various planes, a narrow femoral canal, and increased anteversion of the femur. Over the past two decades, there has been an evolution in computer technologies in total hip arthroplasty from simple navigation systems to advanced robotic platforms. For hip arthroplasty, modern robotic systems use 3D planning based on computed tomography data, which allows minimizing positioning errors of the cup to ≤1° and ≤1 mm, taking into account the patient’s individual anatomical features. The relevance of implementing robotic systems for patients with dysplastic coxarthrosis is confirmed by studies demonstrating a reduction in the incidence of dislocations in robot-assisted operations, as well as a decrease in the risk of aseptic instability, restoration of biomechanical parameters: offset, lower limb length, acetabular reaming while minimizing potential bone defects in the acetabulum for subsequent revision intervention.