  • A Study of Self-Heating Effect Correction Methods for NTC Thermistors

    by Jianping Sun, Hongjun Wang, Jiahao Li, Ting Li, Guangyao Wang, Weiwei Feng, Lan Du, Wei Shan, Liquan Sun

    Correcting for self-heating effects is crucial for minimizing uncertainties in negative temperature coefficient (NTC) thermistor thermometer measurements. This study examined a self-heating effect correction method for NTC thermistors at the triple point of water (TPW) and a water bath under varying currents. The resistance–temperature characteristics of the thermistors over a temperature range of -5 to 35 °C were determined. Both two-current and multi-current methods were applied to correct the self-heating effects in the thermistors. The results showed that excessive excitation current hindered accurate self-heating correction, while a minimal current would result in a high signal-to-noise ratio, with a recommended test current below 20 μA. Moreover, optimizing the current ratio in the two-current method significantly reduced the measurement uncertainty. The multi-current method further reduced the uncertainty, even though this reduction diminished as the number of excitation currents increased. The multi-current method increased the measurement time and experimental complexity. The self-heating effect and its uncertainty reduced with increasing temperature. Considering both measurement uncertainty and ease of implementation, an improved two-current method with a current ratio of 1:2 is suggested for the accurate measurement and correction of self-heating effects in thermistor thermometers. The self-heating effect from the measured resistance value across all temperature ranges should be corrected to ensure accurate and precise temperature measurements.


  • Study on the reproduction method of miniature Ga fixed points for shipborne thermometer calibration

    by Junru Liu, Guangyao Wang, Jiang Pan, Jianping Sun, Ting Li, Chuanjie Wei, Weiwei Feng, Liquan Sun, Ziang Wu, Xingjun Niu

    The onsite calibration precision of the ocean thermometer can be efficiently raised by temperature scale transfer technology based on miniature fixed points. A new reproduction method of miniature Ga fixed points was studied for the sub-millikelvin precision measurement requirement. The onsite calibration system consists of a miniature Ga fixed point and a shipborne calibration device. The performance of miniature Ga fixed point is highly dependent on placement methods and the value-taking methods of phase transition temperature. This paper analyzed and compared the melting plateau of a miniature Ga fixed point with two placement methods and three value-taking methods of phase transition temperatures. The experimental results showed that utilizing horizontal placement and the average value method can achieve fixed point reproducibility within 1 mK. The performance of the miniature Ga fixed point was verified using the SBE 3plus thermometer from the SBE 911plus CTD system, with a thermometer accuracy of ±1 mK. The difference between the measured value by SBE 3plus and the Ga melting plateau value was within 0.5 mK. Thus, the study of the miniature Ga fixed point offers effective technical support for the onsite calibration of ocean thermometer.

  • Study on the Number and Spacing of Calibration Points for High-Precision NTC Thermistors Across the Ocean Temperature Range

    by Liquan Sun, Guangyao Wang, Jianping Sun, Weiwei Feng, Hongjun Wang, Ting Li, Lan Du, Hao Huang, Junru Liu

    Marine monitoring often requires the temperature measurement accuracy to be less than 1 mK. A series of regularly arranged temperature points is taken to calibrate the equation expressing resistance-temperature characteristics under ocean conditions. Seventy-two negative temperature coefficient thermistors underwent coincident measurement procedures with nine equally spaced points from -5 to 35 °C in a high-precision thermostatic water bath, followed by calibration using Lagrange interpolation and least-squares fitting methods. Ten of these thermistors, with average interpolation errors below 0.1 mK and calibration uncertainty estimated at 0.6 mK ( k = 2), were used to study the impact of the number and placement of calibration points on interpolation error, aiming to enhance measurement precision across the ocean temperature range. The results reveal that the standard deviation for the 10 thermistors using six unequally spaced points was only 20% higher than when using nine equally spaced points. However, the standard deviation for five equally spaced points nearly doubled, with a maximum difference of 0.1 mK, still achieving sub-millikelvin accuracy. By adjusting the calibration points near both ends of the range, the optimal placement for five calibration points was found to minimize temperature deviation and adhere to the Chebyshev criterion. This ideal distribution, determined through sequential calculations, contributes to improved calibration precision.