Wenbo Sui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wenbo Sui has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Changyu Shen
College of Optical and Electronic Technology, China Jiliang University , Hangzhou, Zhejiang 310018
3 shared publications - Jun Wu
College of Optical and Electronic Technology
2 shared publications - Jun Zhou
China Jiliang University
2 shared publications - Wenjun Zhou
China Jiliang University, Hangzhou, China
2 shared publications Xijie Feng
College of Optical and Electronic Technology, China Jiliang University, Hangzhou, China
2 shared publications- Yunjie Cao
College of Optical and Electronic Technology, China Jiliang University, Hangzhou, China
2 shared publications
Latest Publications
- 8 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 19203-19209
Trace Chromium Ion Detection Based on 4-Mercaptobenzoic Acid Functionalized Plasmonic Fiber-Optic Spectral Combs
High sensitivity chromium ions (Cr3+) sensor was developed based on the combination of gold nanomaterials-coated tilted fiber Bragg grating (TFBG) and 4-mercaptobenzoic acid (4-MBA). The TFBG was first deposited with a 50 nm gold film to excite sensitive surface plasmonic resonance (SPR) spectral combs and then functionalized with a 4-MBA layer that is available for specifically capturing Cr3+ ions. To further enhance the SPR-Cr3+ interaction, additional gold nanoparticles (AuNPs)-4-MBA composite was prepared and bonded with the Cr3+ captured by the TFBG. Thus, the SPR response to the capture of Cr3+ and the sensing performance were greatly enhanced. Experimental results show that the sensor exhibits a high sensitivity of 1.23 dB/log(nM) for Cr3+ with a detection limit of 0.04 nM, which is lower than that of the current similar optical Cr3+ detection sensor by one order of magnitude.
- 8 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 19203-19209
Trace Chromium Ion Detection Based on 4-Mercaptobenzoic Acid Functionalized Plasmonic Fiber-Optic Spectral Combs
High sensitivity chromium ions (Cr3+) sensor was developed based on the combination of gold nanomaterials-coated tilted fiber Bragg grating (TFBG) and 4-mercaptobenzoic acid (4-MBA). The TFBG was first deposited with a 50 nm gold film to excite sensitive surface plasmonic resonance (SPR) spectral combs and then functionalized with a 4-MBA layer that is available for specifically capturing Cr3+ ions. To further enhance the SPR-Cr3+ interaction, additional gold nanoparticles (AuNPs)-4-MBA composite was prepared and bonded with the Cr3+ captured by the TFBG. Thus, the SPR response to the capture of Cr3+ and the sensing performance were greatly enhanced. Experimental results show that the sensor exhibits a high sensitivity of 1.23 dB/log(nM) for Cr3+ with a detection limit of 0.04 nM, which is lower than that of the current similar optical Cr3+ detection sensor by one order of magnitude.
- 2 December 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (23)
Ultralow limit human IgG detection with 2H-MoS2/L-cysteine based plasmonic fiber-optic spectral combs
The detection of human immunoglobulin G (human IgG) provides crucial evidence in diagnosis of infectious diseases and monitoring of therapeutic effects. Here, we propose a plasmonic fiber-optical surface plasmon resonance (SPR) based sensor to realize the ultralow limit human IgG detection. The proposed sensor is fabricated by attaching a mixture of 2H-MoS2 nanosheets with L-cysteine on a gold-coated tilted fiber Bragg grating. The 2H-MoS2 possesses a large specific surface area, where the L-cysteine can enhance the stability of antibody modification. The composite membrane of 2H-MoS2 and L-cysteine can adsorb more probe rabbit anti-human IgG, which can improve sensitivity of the proposed sensor. The experimental results show that the proposed sensor exhibits a response time of approximately 220 s and a sensitivity of 0.11 dB/(ng/ml). The limit of detection of 0.87 ng/ml of the proposed sensor is one order of magnitude lower than those of other fiber-optic SPR human IgG sensors.
- 2 December 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (23)
Ultralow limit human IgG detection with 2H-MoS2/L-cysteine based plasmonic fiber-optic spectral combs
The detection of human immunoglobulin G (human IgG) provides crucial evidence in diagnosis of infectious diseases and monitoring of therapeutic effects. Here, we propose a plasmonic fiber-optical surface plasmon resonance (SPR) based sensor to realize the ultralow limit human IgG detection. The proposed sensor is fabricated by attaching a mixture of 2H-MoS2 nanosheets with L-cysteine on a gold-coated tilted fiber Bragg grating. The 2H-MoS2 possesses a large specific surface area, where the L-cysteine can enhance the stability of antibody modification. The composite membrane of 2H-MoS2 and L-cysteine can adsorb more probe rabbit anti-human IgG, which can improve sensitivity of the proposed sensor. The experimental results show that the proposed sensor exhibits a response time of approximately 220 s and a sensitivity of 0.11 dB/(ng/ml). The limit of detection of 0.87 ng/ml of the proposed sensor is one order of magnitude lower than those of other fiber-optic SPR human IgG sensors.
- 31 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Trace Detection of Cadmium ion Based on Glutathione-Functionalized TFBG-SPR Sensor
This paper presents a novel cadmium ion sensor that utilizes a tilted fiber Bragg grating functionalized by glutathione. Gold nanoparticles are used to amplify localized refractive index changes. The limit of detection is 0.07 nM.
- 31 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Trace Detection of Cadmium ion Based on Glutathione-Functionalized TFBG-SPR Sensor
This paper presents a novel cadmium ion sensor that utilizes a tilted fiber Bragg grating functionalized by glutathione. Gold nanoparticles are used to amplify localized refractive index changes. The limit of detection is 0.07 nM.