Masaki Okawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Masaki Okawa has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Tsubasa Ikami
Institute of Fluid Science, Tohoku University 1 , 2-1-1 Katahira, Aoba, Sendai, Miyagi 980-8577
3 shared publications - Hiroki Nagai
Institute of Fluid Science, Tohoku University 1 , 2-1-1 Katahira, Aoba, Sendai, Miyagi 980-8577
2 shared publications Kanako Watanabe
Department of Chemical Engineering, Tohoku University, Sendai, Miyagi 980-8579, Japan
2 shared publicationsYuma Yamagishi
Department of Aerospace Engineering, Graduate school of Engineering, Tohoku University, Sendai, Miyagi 980-8579, Japan
2 shared publications- Gabriel Yiting Lim1 shared publication
Hiroki Nagai
Institute of Fluid Science, Tohoku University, 2-1-1, Katahira, Aoba-ku, Sendai, Miyagi 980-8577, Japan
1 shared publication
Latest Publications
- Open Access
- 3 August 2026
- Published by Elsevier in Aerospace Science and Technology
- Vol. 179
Unsteady aerodynamic characteristics of a high-performance pitching airfoil under light dynamic stall at low reynolds number
- 3 August 2026
- Published by Elsevier in Aerospace Science and Technology
- Vol. 179
Open AccessUnsteady aerodynamic characteristics of a high-performance pitching airfoil under light dynamic stall at low reynolds number
- Open Access
- 22 May 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (6) , 069501
Corrigendum: High-luminescence polymer/ceramic pressure-sensitive paint employing low-refractive-index silica nanoparticles (2025 Meas. Sci. Technol. 36 035104)
Corrigendum: High-luminescence polymer/ceramic pressure-sensitive paint employing low-refractive-index silica nanoparticles (2025 Meas. Sci. Technol. 36 035104), Okawa, Maski, Ikami, Tusbasa, Yamagishi, Yuma, Watanabe, Kanako, Ngai, Hiroki
- 22 May 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (6) , 069501
Open AccessCorrigendum: High-luminescence polymer/ceramic pressure-sensitive paint employing low-refractive-index silica nanoparticles (2025 Meas. Sci. Technol. 36 035104)
Corrigendum: High-luminescence polymer/ceramic pressure-sensitive paint employing low-refractive-index silica nanoparticles (2025 Meas. Sci. Technol. 36 035104), Okawa, Maski, Ikami, Tusbasa, Yamagishi, Yuma, Watanabe, Kanako, Ngai, Hiroki
- Open Access
- 11 February 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (3) , 035104
High-luminescence polymer/ceramic pressure-sensitive paint employing low-refractive-index silica nanoparticles
Pressure-sensitive paint (PSP) is an optical pressure-measurement technique that uses oxygen quenching. In unsteady PSP measurements, PSPs necessitate not only pressure sensitivity and response speed but also higher luminescence intensity. In this study, spherical silica nanoparticles are mixed into the paint to achieve a brighter luminescence. We prototype PSPs using particle size and mixing ratio as parameters and evaluate their performance. The results exhibit the luminescence intensity changes due to the low refractive index of silica; the smaller the particle size and the higher the particle ratio, the stronger the luminescence intensity. Silica-based PSPs are approximately 1.5 times brighter than titania-based PSP; which have frequently been used in previous studies. Additionally, a comprehensive performance investigation indicates that the silica-based PSP with the brightest formulation has a pressure sensitivity of 0.72 %/kPa with a response speed of 11.0 µs. These results prove that the higher luminescence is compatible with the high sensitivity and fast response using low-refractive index nanoparticles.
- 11 February 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (3) , 035104
Open AccessHigh-luminescence polymer/ceramic pressure-sensitive paint employing low-refractive-index silica nanoparticles
Pressure-sensitive paint (PSP) is an optical pressure-measurement technique that uses oxygen quenching. In unsteady PSP measurements, PSPs necessitate not only pressure sensitivity and response speed but also higher luminescence intensity. In this study, spherical silica nanoparticles are mixed into the paint to achieve a brighter luminescence. We prototype PSPs using particle size and mixing ratio as parameters and evaluate their performance. The results exhibit the luminescence intensity changes due to the low refractive index of silica; the smaller the particle size and the higher the particle ratio, the stronger the luminescence intensity. Silica-based PSPs are approximately 1.5 times brighter than titania-based PSP; which have frequently been used in previous studies. Additionally, a comprehensive performance investigation indicates that the silica-based PSP with the brightest formulation has a pressure sensitivity of 0.72 %/kPa with a response speed of 11.0 µs. These results prove that the higher luminescence is compatible with the high sensitivity and fast response using low-refractive index nanoparticles.
- Open Access
- 1 December 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (12)
Spatiotemporal feature extraction using frequency-domain approach for flow-field data analysis
Large-scale spatiotemporal data can easily be obtained from fluid-flow measurements owing to the development of measurement instruments. Data-driven analysis methods such as Proper Orthogonal Decomposition (POD) are used to analyze large-scale data and decompose flow-field structures into spatiotemporal correlations. In addition to decomposing the data into modes, selecting and extracting dominant features automatically are necessary. This study proposes a new analysis method that simultaneously selects the dominant POD modes and their corresponding dominant frequencies by estimating the amplitude and initial phase of the POD coefficients in the frequency domain rather than directly estimating the POD coefficients. The proposed method is applied to two types of experimental flow-field data to validate the method. In the first case, the proposed method is applied for noise reduction in pressure-sensitive paint data with a low signal-to-noise ratio. The results show that the proposed method can reduce noise more accurately and naturally than the other methods. In the second case, the dominant frequencies in the flow field and their spatial structures are estimated for vortex shedding at the trailing edge of the National Advisory Committee for Aeronautics 0012 airfoil. The data are acquired using particle image velocimetry. The results show that the proposed method can decompose flow-field data containing multiple frequency components into spatial correlations, and it can be used as a tool for feature extraction in the flow field.
- 1 December 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (12)
Open AccessSpatiotemporal feature extraction using frequency-domain approach for flow-field data analysis
Large-scale spatiotemporal data can easily be obtained from fluid-flow measurements owing to the development of measurement instruments. Data-driven analysis methods such as Proper Orthogonal Decomposition (POD) are used to analyze large-scale data and decompose flow-field structures into spatiotemporal correlations. In addition to decomposing the data into modes, selecting and extracting dominant features automatically are necessary. This study proposes a new analysis method that simultaneously selects the dominant POD modes and their corresponding dominant frequencies by estimating the amplitude and initial phase of the POD coefficients in the frequency domain rather than directly estimating the POD coefficients. The proposed method is applied to two types of experimental flow-field data to validate the method. In the first case, the proposed method is applied for noise reduction in pressure-sensitive paint data with a low signal-to-noise ratio. The results show that the proposed method can reduce noise more accurately and naturally than the other methods. In the second case, the dominant frequencies in the flow field and their spatial structures are estimated for vortex shedding at the trailing edge of the National Advisory Committee for Aeronautics 0012 airfoil. The data are acquired using particle image velocimetry. The results show that the proposed method can decompose flow-field data containing multiple frequency components into spatial correlations, and it can be used as a tool for feature extraction in the flow field.