YZYuying Zhou

Yuying Zhou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuying Zhou has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High-κ dielectric materials in EWOD device

    by Xiang Ao, Yuying Zhou, Tongshi Feng, Rui Liu, Shengfa Liang, Wenchang Zhang


  • High-Sensitivity InGaZnO FET Sensor Array With Offset Self-Calibration for Multibiomarker Sensing

    by Yao Li, Yuying Zhou, Bing Chen, Shuaidi Zhang, Ke Hu, Peiyun Li, Congyan Lu, Jiawei Wang, Xiaonan Yang, Feng Zhang, et al.

    This work proposes a dual-gate InGaZnO thin-film transistor sensor array for label-free and cross-scale multiple biomarkers detection, including single-stranded deoxyribonucleic acid (ssDNA) and protein CA125. We exploit dual gate modulation for threshold voltage and CMOS-based SAR-assisted digital-to-analog converter (DAC) VBG calibration circuit to eliminate initial VTH offset variation caused by different functionalizations, which improve the reliability of the multibiomarker sensor array. At the same time, receptor enhancement on the indium gallium zinc oxide (IGZO) sensing membrane was detected by fluorescence assay, realizing higher sensitivity for biosensor. We demonstrate the sensor array response for pH in static and real-time mode, realizing near-Nernst limit sensitivity (55.02 mV/pH). Furthermore, at the top-gate configuration, with low operation voltage (0.1 V) and low offset variation (about 2 nA), the IGZO sensor array exhibits great performance for biomarker sensing which achieves sensitivity up to 4.426%/decade for ssDNA and 1102 nA/decade for CA125, with the limit of detection (LoD) of 1.67 aM for ssDNA and 0.1 fg/mL for CA125. This biosensor array provides a potential approach to realize miniaturization and high-density integration of multidimensional-biomarker detection.


  • Open Access

    Recent Advances in Enhancing the Sensitivity of Biosensors Based on Field Effect Transistors

    by Yuying Zhou, Tongshi Feng, Yao Li, Xiang Ao, Shengfa Liang, Xiaonan Yang, Lingfei Wang, Xiaoxin Xu, Wenchang Zhang

    Biosensors based on field effect transistor (FET), also known as Bio‐FETs, offer numerous advantages, including high sensitivity, rapid response speed, low operating voltage, compact size, high reliability, and easily integrative. These features endow Bio‐FETs with tremendous performance in rapid analysis for samples with ultra‐low concentration at large‐scale, broadening their multiple potential applications. In recent years, the research based on Bio‐FETs has attracted more and more attention. A lot of effort is put into the challenge to improve their sensitivity, which can be influenced by various factors. This review focuses on the current approaches from multiple perspectives, including overcoming the influence of Debye shielding effects, promoting the binding efficiency of analytes and FETs surface, and improving the structures of FETs device. Correspondingly, novel strategies to increase the Debye length, facilitate high frequency electric field modulation, enhance the specific interaction efficiency, and enlarge the specific surface area (SBET) are also summarized. Additionally, there is a lack of a reliable standard method to characterize the sensitivity of FETs currently. Regarding this issue, the most commonly used definitions and representation parameters of sensitivity are also evaluated. Overall, this review outlines the potential future research directions to offer insights for enhancing the sensitivity of Bio‐FETs.