AKAlexander Küenzi
Alexander Küenzi
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alexander Küenzi has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Cedric Bessire
School of Engineering and Computer Science, Bern University of Applied Science, 2501 Biel, Switzerland
3 shared publications - Matt Stark
Institute for Human Centered Engineering (HuCE), Bern University of Applied Sciences (BFH), Quellgasse 21, Biel, 2501, Bern, Switzerland
2 shared publications - Sandro Carrara
École Polytechnique Fédérale de Lausanne
2 shared publications - Adel Ghezri
School of Biomedical and Precision Engineering, Bern University, 3010 Bern, Switzerland
1 shared publication - Amirmahdi Tavakolidakhrabadi
Institute for Human Centered Engineering HuCE, Department of Engineering and Computer Science, Bern University of Applied Sciences, 2501 Biel, Switzerland
1 shared publication - Christof Grüring
Department of Medical Parasitology and Infection Biology, Swiss Tropical and Public Health Institute
1 shared publication
Latest Publications
- Open Access
- 29 June 2026
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 311, 118956
A novel capillary-driven dual-mode imaging flow cytometry system for malaria parasite detection and quantification
- 29 June 2026
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 311, 118956
Open AccessA novel capillary-driven dual-mode imaging flow cytometry system for malaria parasite detection and quantification
- Open Access
- 26 March 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (4) , 214
Optimized Microfluidic Biosensor for Sensitive C-Reactive Protein Detection
Lateral flow immunoassays (LFIAs) were integrated into microfluidic chips and tested to enhance point-of-care testing (POCT), with the aim of improving sensitivity and expanding the range of CRP detection. The microfluidic approach improves upon traditional methods by precisely controlling fluid speed, thus enhancing sensitivity and accuracy in CRP measurements. The microfluidic approach also enables a one-step detection system, eliminating the need for buffer solution steps and reducing the nitrocellulose (NC) pad area to just the detection test line. This approach minimizes the non-specific binding of conjugated antibodies to unwanted areas of the NC pad, eliminating the need to block those areas, which enhances the sensitivity of detection. The gold nanoparticle method detects CRP in the high-sensitivity range of 1–10 g/mL, which is suitable for chronic disease monitoring. To broaden the CRP detection range, including infection levels beyond 10 g/mL, fluorescent labels were introduced, extending the measuring range from 1 to 70 g/mL. Experimental results demonstrate that integrating microfluidic technology significantly enhances operational efficiency by precisely controlling the flow rate and optimizing the mixing efficiency while reducing fabrication resources by eliminating the need for separate pads, making these methods suitable for resource-limited settings. Microfluidics also provides greater control over fluid dynamics compared to traditional LFIA methods, which contributes to enhanced detection sensitivity even with lower sample volumes and no buffer solution, helping to enhance the usability of POCT. These findings highlight the potential to develop accessible, accurate, and cost-effective diagnostic tools essential for timely medical interventions at the POC.- 26 March 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (4) , 214
Open AccessOptimized Microfluidic Biosensor for Sensitive C-Reactive Protein Detection
Lateral flow immunoassays (LFIAs) were integrated into microfluidic chips and tested to enhance point-of-care testing (POCT), with the aim of improving sensitivity and expanding the range of CRP detection. The microfluidic approach improves upon traditional methods by precisely controlling fluid speed, thus enhancing sensitivity and accuracy in CRP measurements. The microfluidic approach also enables a one-step detection system, eliminating the need for buffer solution steps and reducing the nitrocellulose (NC) pad area to just the detection test line. This approach minimizes the non-specific binding of conjugated antibodies to unwanted areas of the NC pad, eliminating the need to block those areas, which enhances the sensitivity of detection. The gold nanoparticle method detects CRP in the high-sensitivity range of 1–10 g/mL, which is suitable for chronic disease monitoring. To broaden the CRP detection range, including infection levels beyond 10 g/mL, fluorescent labels were introduced, extending the measuring range from 1 to 70 g/mL. Experimental results demonstrate that integrating microfluidic technology significantly enhances operational efficiency by precisely controlling the flow rate and optimizing the mixing efficiency while reducing fabrication resources by eliminating the need for separate pads, making these methods suitable for resource-limited settings. Microfluidics also provides greater control over fluid dynamics compared to traditional LFIA methods, which contributes to enhanced detection sensitivity even with lower sample volumes and no buffer solution, helping to enhance the usability of POCT. These findings highlight the potential to develop accessible, accurate, and cost-effective diagnostic tools essential for timely medical interventions at the POC. - Open Access
- 12 December 2024
- Published by MDPI AG in Journal of Manufacturing and Materials Processing
- Vol. 8 (6) , 289
Energy Efficient Jet Polishing via Electrolytic Plasma Enhances Corrosion Resistance in Stainless Steel
This study systematically compares the surface polishing performance and finishing results of the following two different electrolytic plasma polishing technologies on stainless steel AISI 316L: (i) plasma electrolytic polishing (PEP) and (ii) plasma electrolytic polishing jet (PEP-Jet). The two techniques are compared against an industrial standard polishing method, electropolishing (EP). For comparable energy density consumption, the samples treated with the PEP-Jet technique showed the highest removal rate, up to three times less than the initial roughness, resulting in the highest surface roughness reduction from Sa = 249 nm to Sa = 81 nm. Microstructure characterization of samples treated using PEP-Jet also showed well-defined crystalline grain boundaries with a distinct appearance of predominantly inter-crystalline structures within individual grains, which is uncommon with EP techniques. The surfaces treated using PEP-Jet exhibited the lowest corrosion rate of mm/year, and no signs of areal corrosion were detected in the performed corrosion tests in contrast with the other samples and their respective treatments. The comparative analysis revealed that the high ionic current delivered by the electrolyte jet flow in the PEP-Jet process effectively stabilizes the plasma at the contact zone, thereby enhancing the plasma polishing of austenitic stainless steel samples. The efficacy of this method has been demonstrated in terms of reducing energy consumption and enhancing corrosion resistance in comparison with (PEP) and (EP) as state-of-the-art processes in corrosive environments of high-alloyed steel.- 12 December 2024
- Published by MDPI AG in Journal of Manufacturing and Materials Processing
- Vol. 8 (6) , 289
Open AccessEnergy Efficient Jet Polishing via Electrolytic Plasma Enhances Corrosion Resistance in Stainless Steel
This study systematically compares the surface polishing performance and finishing results of the following two different electrolytic plasma polishing technologies on stainless steel AISI 316L: (i) plasma electrolytic polishing (PEP) and (ii) plasma electrolytic polishing jet (PEP-Jet). The two techniques are compared against an industrial standard polishing method, electropolishing (EP). For comparable energy density consumption, the samples treated with the PEP-Jet technique showed the highest removal rate, up to three times less than the initial roughness, resulting in the highest surface roughness reduction from Sa = 249 nm to Sa = 81 nm. Microstructure characterization of samples treated using PEP-Jet also showed well-defined crystalline grain boundaries with a distinct appearance of predominantly inter-crystalline structures within individual grains, which is uncommon with EP techniques. The surfaces treated using PEP-Jet exhibited the lowest corrosion rate of mm/year, and no signs of areal corrosion were detected in the performed corrosion tests in contrast with the other samples and their respective treatments. The comparative analysis revealed that the high ionic current delivered by the electrolyte jet flow in the PEP-Jet process effectively stabilizes the plasma at the contact zone, thereby enhancing the plasma polishing of austenitic stainless steel samples. The efficacy of this method has been demonstrated in terms of reducing energy consumption and enhancing corrosion resistance in comparison with (PEP) and (EP) as state-of-the-art processes in corrosive environments of high-alloyed steel.