Hien Thi Hoang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hien Thi Hoang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Duc-Anh Nguyen
Ophthalmology Department, Hanoi Medical University, Hanoi, Vietnam
2 shared publications - Quoc Tung Mai
Department of Ophthalmology, Hanoi Medical University, Hanoi, Vietnam
2 shared publications - Simon Edward Skalicky
Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, Australia
2 shared publications - Tung Thanh Hoang
Ophthalmology Department, Hanoi Medical University, Hanoi, Vietnam
2 shared publications Deus Bigirimana
Univ Melbourne, Dept Surg, Melbourne, Vic, Australia
1 shared publication- Diu Thi Vu
Ophthalmology Department, Hanoi Medical University, Hanoi, Vietnam
1 shared publication
Latest Publications
- Open Access
- 1 April 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 1263-1276
Glaucoma Home Monitoring Using Online Circular Contrast Perimetry Over 6 Months: Performance and Patient Attitudes in the Developing World Setting
Purpose: Online circular contrast perimetry (OCCP) provides perimetry on any computer or tablet without additional hardware. This study assessed the longitudinal performance and user feedback of home OCCP in an Asian population. Methods: Twenty glaucoma and fifteen healthy participants underwent a comprehensive ocular examination and visual field tests in clinic, using OCCP and standard automated perimetry. Within a week, participants were asked to repeat OCCP at home. OCCP was then repeated after 3 months and 6 months at home, followed by a user-experience survey. Results: No significant difference between clinic and home OCCP for test duration, false negative (FN) and fixation loss (FL) rates was found. False positive (FP) rate of home OCCP was slightly higher than that of clinic OCCP (p = 0.04). Bland-Altman plots indicated a small difference between Mean Deviation (MD) (1.26 dB, p = 0.0087) and good agreements between Pattern Standard Deviation (PSD) and Visual Index (VI) of clinic OCCP and home OCCP with insignificant difference of PSD and VI (p > 0.05). Intraclass correlation coefficient (ICC) analysis demonstrated good correlation of MD & VI and poor correlation of PSD between clinic OCCP and home OCCP. Over 6 months, home OCCP indicated moderate to excellent correlation of indices. Participants reported a positive attitude toward home OCCP; however, a high dropout rate was noted for the 3- and 6-month at-home testing. Conclusion: Comparable results were observed between clinic and home OCCP at baseline. Acceptable consistency of home OCCP findings over 6 months was recognized. Patients may require additional support to achieve desired adherence to at-home monitoring protocols.
- 1 April 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 1263-1276
Open AccessGlaucoma Home Monitoring Using Online Circular Contrast Perimetry Over 6 Months: Performance and Patient Attitudes in the Developing World Setting
Purpose: Online circular contrast perimetry (OCCP) provides perimetry on any computer or tablet without additional hardware. This study assessed the longitudinal performance and user feedback of home OCCP in an Asian population. Methods: Twenty glaucoma and fifteen healthy participants underwent a comprehensive ocular examination and visual field tests in clinic, using OCCP and standard automated perimetry. Within a week, participants were asked to repeat OCCP at home. OCCP was then repeated after 3 months and 6 months at home, followed by a user-experience survey. Results: No significant difference between clinic and home OCCP for test duration, false negative (FN) and fixation loss (FL) rates was found. False positive (FP) rate of home OCCP was slightly higher than that of clinic OCCP (p = 0.04). Bland-Altman plots indicated a small difference between Mean Deviation (MD) (1.26 dB, p = 0.0087) and good agreements between Pattern Standard Deviation (PSD) and Visual Index (VI) of clinic OCCP and home OCCP with insignificant difference of PSD and VI (p > 0.05). Intraclass correlation coefficient (ICC) analysis demonstrated good correlation of MD & VI and poor correlation of PSD between clinic OCCP and home OCCP. Over 6 months, home OCCP indicated moderate to excellent correlation of indices. Participants reported a positive attitude toward home OCCP; however, a high dropout rate was noted for the 3- and 6-month at-home testing. Conclusion: Comparable results were observed between clinic and home OCCP at baseline. Acceptable consistency of home OCCP findings over 6 months was recognized. Patients may require additional support to achieve desired adherence to at-home monitoring protocols.
- Open Access
- 1 December 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 3767-3780
Glaucoma Clinic Monitoring Over 6 Months Using Online Circular Contrast Perimetry in Comparison with Standard Automatic Perimetry: The Developing-World Setting
Purpose: Online circular contrast perimetry provides visual field testing on any computer or tablet without additional hardware. This study compared outcomes of online circular contrast perimetry (OCCP) and standard automated perimetry (SAP) in a developing world setting. Methods: The longitudinal and observation study was conducted on patients sampled during 2023 at Hanoi Medical University Hospital. Participants were either healthy volunteers as controls or stable glaucoma patients with either primary angle closure or primary open-angle glaucoma. They underwent a comprehensive ocular examination, retinal nerve fiber layer optical coherence tomography scan, and visual field tests performed at baseline and after 3 months and 6 months, using OCCP and SAP in clinic. Results: The current study was carried out in 168 eyes of 87 patients at baseline, 133 eyes of 69 patients at 3 months, and 121 eyes of 63 patients at 6 months. At baseline, OCCP mean deviation (MD) (R2 = 0.804, p < 0.001) and visual index (VI) (R2 = 0.892, p < 0.001) were strongly correlated with SAP MD and visual field index (VFI) respectively. There was strong agreement and correlation between MD and VI/VFI for SAP and OCCP on repeated testing after 6 months. At 6 months AUC of SAP VFI (0.79) was superior to AUC of OCCP VI (0.67, p = 0.036); otherwise there was no difference in AUC of MD or VI/VFI at baseline, 3 and 6 months, when comparing OCCP and SAP. Conclusion: OCCP parameters are significantly correlated with those of SAP. OCCP has the potential to provide a complementary role to SAP in glaucoma screening and monitoring.
- 1 December 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 3767-3780
Open AccessGlaucoma Clinic Monitoring Over 6 Months Using Online Circular Contrast Perimetry in Comparison with Standard Automatic Perimetry: The Developing-World Setting
Purpose: Online circular contrast perimetry provides visual field testing on any computer or tablet without additional hardware. This study compared outcomes of online circular contrast perimetry (OCCP) and standard automated perimetry (SAP) in a developing world setting. Methods: The longitudinal and observation study was conducted on patients sampled during 2023 at Hanoi Medical University Hospital. Participants were either healthy volunteers as controls or stable glaucoma patients with either primary angle closure or primary open-angle glaucoma. They underwent a comprehensive ocular examination, retinal nerve fiber layer optical coherence tomography scan, and visual field tests performed at baseline and after 3 months and 6 months, using OCCP and SAP in clinic. Results: The current study was carried out in 168 eyes of 87 patients at baseline, 133 eyes of 69 patients at 3 months, and 121 eyes of 63 patients at 6 months. At baseline, OCCP mean deviation (MD) (R2 = 0.804, p < 0.001) and visual index (VI) (R2 = 0.892, p < 0.001) were strongly correlated with SAP MD and visual field index (VFI) respectively. There was strong agreement and correlation between MD and VI/VFI for SAP and OCCP on repeated testing after 6 months. At 6 months AUC of SAP VFI (0.79) was superior to AUC of OCCP VI (0.67, p = 0.036); otherwise there was no difference in AUC of MD or VI/VFI at baseline, 3 and 6 months, when comparing OCCP and SAP. Conclusion: OCCP parameters are significantly correlated with those of SAP. OCCP has the potential to provide a complementary role to SAP in glaucoma screening and monitoring.