Diu Thi Vu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Diu Thi Vu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Duc-Anh Nguyen
Ophthalmology Department, Hanoi Medical University, Hanoi, Vietnam
1 shared publication - Dung Thi Pham
Ophthalmology Department, Hanoi Medical University, Hanoi, Vietnam
1 shared publication - Hien Thi Hoang
Ophthalmology Department, Hanoi Medical University, Hanoi, Vietnam
1 shared publication - Quoc Tung Mai
Department of Ophthalmology, Hanoi Medical University, Hanoi, Vietnam
1 shared publication - Simon Edward Skalicky
Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, Australia
1 shared publication - Tung Thanh Hoang
Ophthalmology Department, Hanoi Medical University, Hanoi, Vietnam
1 shared publication
Latest Publications
- Open Access
- 1 April 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 1263-1276
Glaucoma Home Monitoring Using Online Circular Contrast Perimetry Over 6 Months: Performance and Patient Attitudes in the Developing World Setting
Purpose: Online circular contrast perimetry (OCCP) provides perimetry on any computer or tablet without additional hardware. This study assessed the longitudinal performance and user feedback of home OCCP in an Asian population. Methods: Twenty glaucoma and fifteen healthy participants underwent a comprehensive ocular examination and visual field tests in clinic, using OCCP and standard automated perimetry. Within a week, participants were asked to repeat OCCP at home. OCCP was then repeated after 3 months and 6 months at home, followed by a user-experience survey. Results: No significant difference between clinic and home OCCP for test duration, false negative (FN) and fixation loss (FL) rates was found. False positive (FP) rate of home OCCP was slightly higher than that of clinic OCCP (p = 0.04). Bland-Altman plots indicated a small difference between Mean Deviation (MD) (1.26 dB, p = 0.0087) and good agreements between Pattern Standard Deviation (PSD) and Visual Index (VI) of clinic OCCP and home OCCP with insignificant difference of PSD and VI (p > 0.05). Intraclass correlation coefficient (ICC) analysis demonstrated good correlation of MD & VI and poor correlation of PSD between clinic OCCP and home OCCP. Over 6 months, home OCCP indicated moderate to excellent correlation of indices. Participants reported a positive attitude toward home OCCP; however, a high dropout rate was noted for the 3- and 6-month at-home testing. Conclusion: Comparable results were observed between clinic and home OCCP at baseline. Acceptable consistency of home OCCP findings over 6 months was recognized. Patients may require additional support to achieve desired adherence to at-home monitoring protocols.
- 1 April 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 1263-1276
Open AccessGlaucoma Home Monitoring Using Online Circular Contrast Perimetry Over 6 Months: Performance and Patient Attitudes in the Developing World Setting
Purpose: Online circular contrast perimetry (OCCP) provides perimetry on any computer or tablet without additional hardware. This study assessed the longitudinal performance and user feedback of home OCCP in an Asian population. Methods: Twenty glaucoma and fifteen healthy participants underwent a comprehensive ocular examination and visual field tests in clinic, using OCCP and standard automated perimetry. Within a week, participants were asked to repeat OCCP at home. OCCP was then repeated after 3 months and 6 months at home, followed by a user-experience survey. Results: No significant difference between clinic and home OCCP for test duration, false negative (FN) and fixation loss (FL) rates was found. False positive (FP) rate of home OCCP was slightly higher than that of clinic OCCP (p = 0.04). Bland-Altman plots indicated a small difference between Mean Deviation (MD) (1.26 dB, p = 0.0087) and good agreements between Pattern Standard Deviation (PSD) and Visual Index (VI) of clinic OCCP and home OCCP with insignificant difference of PSD and VI (p > 0.05). Intraclass correlation coefficient (ICC) analysis demonstrated good correlation of MD & VI and poor correlation of PSD between clinic OCCP and home OCCP. Over 6 months, home OCCP indicated moderate to excellent correlation of indices. Participants reported a positive attitude toward home OCCP; however, a high dropout rate was noted for the 3- and 6-month at-home testing. Conclusion: Comparable results were observed between clinic and home OCCP at baseline. Acceptable consistency of home OCCP findings over 6 months was recognized. Patients may require additional support to achieve desired adherence to at-home monitoring protocols.