Silvia de la Cruz-Jiménez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Silvia de la Cruz-Jiménez has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Álvaro Zubizarreta-Macho
Faculty of Dentistry, Alfonso X El Sabio University, 28691 Madrid, Spain
3 shared publications - Ana Belén Lobo Galindo
Department of Surgery, Faculty of Medicine, University of Salamanca, 37008 Salamanca, Spain
2 shared publications - Javier Flores-Fraile
Department of Surgery, Faculty of Medicine, University of Salamanca, Salamanca, Spain
2 shared publications - Paloma Martínez-Alcaraz
Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain
2 shared publications - Rubén Agustín-Panadero
Department of Stomatology, Faculty of Medicine and Dentistry, Universitat de València, 46010 Valencia, Spain
2 shared publications Charles Menouillard
Facultad de Odontología, Universidad Alfonso X el Sabio (UAX). RET4ODN Research Group, Villanueva de la Cañada, España
1 shared publication
Latest Publications
- Open Access
- 14 November 2026
- Published by Springer Nature in International Journal of Implant Dentistry
Impact of implant surface decontamination techniques on probing depth reduction in peri-implantitis: a meta-analysis of randomized controlled trials
Purpose: To evaluate the effectiveness of surgical and non-surgical interventions, with or without adjunctive therapies, for reducing probing depth (PD) in peri-implantitis through a systematic review and meta-analysis of randomized controlled trials (RCTs). Methods: This systematic review and meta-analysis was conducted according to PRISMA 2020 guidelines and registered in PROSPERO (CRD42021226821). Electronic searches were performed in PubMed, Scopus, and Web of Science to identify RCTs evaluating peri-implantitis treatments. The primary outcome was mean PD reduction at 6, 12, and 36 months. Methodological quality was assessed using the Jadad scale. Subgroup meta-analyses were performed using a random-effects model. Results: Ten unique RCTs, reported across 11 publications and follow-up reports, met the inclusion criteria. At 6 months, access flap surgery without regenerative procedures demonstrated the greatest PD reduction (− 3.39 mm; 95% CI: −3.72 to − 3.05) with no heterogeneity (I² = 0%). Resective surgery combined with adjunctive antibiotics and regenerative surgery using xenografts also achieved significant PD reductions, although substantial heterogeneity was observed. At 12 and 36 months, access flap surgery remained the most consistent intervention. Trim-and-fill analyses indicated no relevant publication bias. Although all treatment modalities were associated with clinical improvements, no approach demonstrated consistent superiority across all follow-up periods. Conclusions: Surgical and non-surgical interventions for peri-implantitis are effective in reducing probing depth. Access flap surgery without regenerative procedures showed the most consistent short- and medium-term outcomes; however, current evidence does not support the superiority of any single treatment modality across all follow-up periods. Further well-designed RCTs with standardized outcome measures are required.
- 14 November 2026
- Published by Springer Nature in International Journal of Implant Dentistry
Open AccessImpact of implant surface decontamination techniques on probing depth reduction in peri-implantitis: a meta-analysis of randomized controlled trials
Purpose: To evaluate the effectiveness of surgical and non-surgical interventions, with or without adjunctive therapies, for reducing probing depth (PD) in peri-implantitis through a systematic review and meta-analysis of randomized controlled trials (RCTs). Methods: This systematic review and meta-analysis was conducted according to PRISMA 2020 guidelines and registered in PROSPERO (CRD42021226821). Electronic searches were performed in PubMed, Scopus, and Web of Science to identify RCTs evaluating peri-implantitis treatments. The primary outcome was mean PD reduction at 6, 12, and 36 months. Methodological quality was assessed using the Jadad scale. Subgroup meta-analyses were performed using a random-effects model. Results: Ten unique RCTs, reported across 11 publications and follow-up reports, met the inclusion criteria. At 6 months, access flap surgery without regenerative procedures demonstrated the greatest PD reduction (− 3.39 mm; 95% CI: −3.72 to − 3.05) with no heterogeneity (I² = 0%). Resective surgery combined with adjunctive antibiotics and regenerative surgery using xenografts also achieved significant PD reductions, although substantial heterogeneity was observed. At 12 and 36 months, access flap surgery remained the most consistent intervention. Trim-and-fill analyses indicated no relevant publication bias. Although all treatment modalities were associated with clinical improvements, no approach demonstrated consistent superiority across all follow-up periods. Conclusions: Surgical and non-surgical interventions for peri-implantitis are effective in reducing probing depth. Access flap surgery without regenerative procedures showed the most consistent short- and medium-term outcomes; however, current evidence does not support the superiority of any single treatment modality across all follow-up periods. Further well-designed RCTs with standardized outcome measures are required.
- Open Access
- 20 February 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (3) , 76
Evaluating the Impact of Pontic Geometry on Load to Failure and Displacement in Implant-Supported Monolithic Zirconia Prostheses: An In Vitro Analysis
The pontic design may influence the load-to-failure performance of fixed implant-supported screw-retained monolithic zirconia prostheses. This study aimed to evaluate the effect of pontic geometry on the fracture resistance of such restorations. Forty restorations were designed using dental CAD software and divided into four groups (n = 10 each): (A) Flat + Wide—pontics with a flat contour, 10 mm in width and 8 mm in height; (B) Concave + Wide—pontics with a concave contour, 10 mm in width and 5.5 mm in height; (C) Flat + Narrow—pontics with a flat contour, 6 mm in width and 8 mm in height; and (D) Concave + Narrow—pontics with a concave contour, 6 mm in width and 5.5 mm in height. All specimens underwent thermal and mechanical cycling, followed by a fracture load test using a three-point bending setup. Maximum fracture loads and displacements were analyzed using one-way ANOVA. Statistically significant differences were observed among the groups for both load to failure (p = 0.001) and displacement (p = 0.002). These findings indicate that pontic geometry significantly influences the fracture resistance and deformation behavior of monolithic zirconia prostheses.
- 20 February 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (3) , 76
Open AccessEvaluating the Impact of Pontic Geometry on Load to Failure and Displacement in Implant-Supported Monolithic Zirconia Prostheses: An In Vitro Analysis
The pontic design may influence the load-to-failure performance of fixed implant-supported screw-retained monolithic zirconia prostheses. This study aimed to evaluate the effect of pontic geometry on the fracture resistance of such restorations. Forty restorations were designed using dental CAD software and divided into four groups (n = 10 each): (A) Flat + Wide—pontics with a flat contour, 10 mm in width and 8 mm in height; (B) Concave + Wide—pontics with a concave contour, 10 mm in width and 5.5 mm in height; (C) Flat + Narrow—pontics with a flat contour, 6 mm in width and 8 mm in height; and (D) Concave + Narrow—pontics with a concave contour, 6 mm in width and 5.5 mm in height. All specimens underwent thermal and mechanical cycling, followed by a fracture load test using a three-point bending setup. Maximum fracture loads and displacements were analyzed using one-way ANOVA. Statistically significant differences were observed among the groups for both load to failure (p = 0.001) and displacement (p = 0.002). These findings indicate that pontic geometry significantly influences the fracture resistance and deformation behavior of monolithic zirconia prostheses.
- Open Access
- 18 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (24) , 11846
Retrievability of Fractured Abutment Screws and Damage to Implant–Abutment Connections: An In Vitro Comparative Analysis of Conventional vs. Drilling Techniques
This study aimed to evaluate the retrievability and potential damage to implant–abutment connections caused by fractured abutment screw removal using conventional and drilling techniques. A total of forty abutment screws were randomly inserted into forty dental implants, and then they were fractured and extracted using different removal methods: Group A employed a conventional approach utilizing an exploration probe and an ultrasonic device without irrigation (n = 10) (conventional); Group B used the Phibo drilling removal system without irrigation (n = 10) (Phibo); Group C utilized the Rhein83® drilling removal system without irrigation (n = 10) (Rhein83); and Group D implemented the Sanhigia® drilling removal system without irrigation (n = 10) (Sanhigia). Pre- and postoperative micro-computed tomography (micro-CT) scans were performed on the dental implants, and Standard Tessellation Language (STL) digital files were generated for morphometric analysis to measure the wear volume. ANOVA was used to assess the volumetric differences (mm3) and percentage ratios of the internal thread volumes of the implant–abutment connections before and after the procedures. Results: This study found no statistically significant differences in the volumetric and percentage ratios of internal threads among the implant groups (Phibo, Rhein83, Sanhigia, and conventional). However, the success rate for retrieving fractured abutment screws was higher (90%) with the drilling systems compared to the conventional technique (50%). These results suggest that drilling systems are more effective for the retrieval of damaged screws. Although drilling techniques without irrigation demonstrated higher removal efficiency compared to the conventional method, both approaches resulted in similar wear volumes at the implant–abutment connections when used to extract fractured screws.
- 18 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (24) , 11846
Open AccessRetrievability of Fractured Abutment Screws and Damage to Implant–Abutment Connections: An In Vitro Comparative Analysis of Conventional vs. Drilling Techniques
This study aimed to evaluate the retrievability and potential damage to implant–abutment connections caused by fractured abutment screw removal using conventional and drilling techniques. A total of forty abutment screws were randomly inserted into forty dental implants, and then they were fractured and extracted using different removal methods: Group A employed a conventional approach utilizing an exploration probe and an ultrasonic device without irrigation (n = 10) (conventional); Group B used the Phibo drilling removal system without irrigation (n = 10) (Phibo); Group C utilized the Rhein83® drilling removal system without irrigation (n = 10) (Rhein83); and Group D implemented the Sanhigia® drilling removal system without irrigation (n = 10) (Sanhigia). Pre- and postoperative micro-computed tomography (micro-CT) scans were performed on the dental implants, and Standard Tessellation Language (STL) digital files were generated for morphometric analysis to measure the wear volume. ANOVA was used to assess the volumetric differences (mm3) and percentage ratios of the internal thread volumes of the implant–abutment connections before and after the procedures. Results: This study found no statistically significant differences in the volumetric and percentage ratios of internal threads among the implant groups (Phibo, Rhein83, Sanhigia, and conventional). However, the success rate for retrieving fractured abutment screws was higher (90%) with the drilling systems compared to the conventional technique (50%). These results suggest that drilling systems are more effective for the retrieval of damaged screws. Although drilling techniques without irrigation demonstrated higher removal efficiency compared to the conventional method, both approaches resulted in similar wear volumes at the implant–abutment connections when used to extract fractured screws.