YKYurii Khomiak

Yurii Khomiak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yurii Khomiak has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    INFLUENCE OF THE COMPUTATIONAL DOMAIN AND MESH ON THE SIGNAL IN EDDY CURRENT TESTING

    by Khomiak Yurii, Mykyta Noskov, Yevhenii Ivashchenko

    Introduction. This paper investigates the influence of numerical simulation parameters for eddy current testing on the characteristics of the output signal during the simulation of a defect’s movement relative to the measuring coil. The objective of this work is to determine optimal parameters for the computational domain, the local finite-element mesh, and the convergence criterion that ensure a smooth output signal in eddy current testing problems when a defect moves relative to the coil. The relevance of this research stems from the widespread use of the finite element method for analyzing electromagnetic processes in nondestructive testing and the need to ensure high reliability of numerical simulation results. Materials and Methods. The study was conducted using numerical modeling of electromagnetic processes in eddy current testing with the application of the finite element method. The influence of the computational domain dimensions and the parameters of the finite-element mesh on the magnetic flux through the coil and the smoothness of the output signal was investigated as the defect position varied relative to the coil. The dimensions of the computational domain relative to the coil diameter were varied, as was the maximum mesh element size in the coil and defect regions. The convergence of the numerical solution was evaluated using the energy error and energy change criteria. To quantitatively assess signal smoothness, a criterion based on the second difference of discrete magnetic flux values was used. Results. Our research has shown that one of the determining factors is the size of the computational domain. It has been established that the size of the region along the (Z) axis — which corresponds to the direction of field propagation from the coil into the surrounding air — has the greatest influence. An analysis of the discretization parameters showed that it is not the overall mesh density that is decisive, but rather its local refinement in regions with high field gradients. Conclusions. Rational parameters for the computational domain have been established for the model under study. Further increasing the range beyond the specified values does not significantly improve signal quality. To quantitatively control numerical noise, an additional smoothness criterion based on the second derivative of the signal is proposed, which allows for the evaluation of local oscillations in the output signal. The results obtained can be used to select optimal parameters for finite-element models of eddy current testing, taking into account signal quality and the required computational cost.

  • Open Access

    Parametric analysis of an orthogonal eddy current transducer for measuring the thickness of dielectric coatings

    by Yurii Khomiak, Mykyta Noskov

    This paper investigates the parameters of orthogonal eddy current transducers (ECTs) for measuring dielectric coating thickness on electrically conductive substrates—a critical task for ensuring product durability and material savings in mechanical engineering, aerospace, and energy applications. The study aims to determine how transducer geometry, excitation frequency, and lift-off influence the useful signal amplitude and signal-to-noise ratio (SNR). Experiments were performed using three ECT variants of different sizes on brass, aluminum, and steel substrates. The results show that the signal amplitude changes monotonically with lift-off, exhibiting maximum sensitivity at small gaps. Signal normalization reveals that the calibration curves are practically frequency-independent, enabling a common normalized characteristic for transducers of the same type. SNR analysis indicates a maximum near 800 kHz for small-sized ECTs, whereas larger transducers peak within the 200–400 kHz range. Furthermore, the upper limit of measurable coating thickness is determined by the width of the active zone b, requiring larger transducers for thicker coatings. The practical significance of this work lies in optimizing the frequency and geometric parameters of ECTs to improve measurement accuracy, simplify high-frequency circuitry, and reduce material waste during quality control.

  • Open Access

    Assessment of the effect of structural and geophysical parameters on the magnetic field distribution around power lines located in underground collectors

    by D.O. Danylchenko, S.YU. Shevchenko, Y.V. Khomiak, A.E. Potryvai

    Purpose. To quantitatively estimate the contribution of the surrounding-medium parameters to the magnetic flux density of a three-phase 110 kV air-insulated transmission line installed inside an underground tunnel, and to clarify whether such parameters must be included in routine engineering magnetic-field assessments. Methodology. Numerical quasi-stationary simulation of the magnetic field at industrial frequency was carried out for a symmetric three-phase system of AC-240/32 conductors loaded with 500 A. The computational domain was decomposed into five characteristic horizontal layers extending from the open air above the ground surface to the very plane of the phase wires. Two parametric series were performed: in the first the soil resistivity was scanned from 50 to 1000 Ω·m at a fixed wall thickness; in the second the concrete-wall thickness was varied from 250 to 500 mm at a fixed soil resistivity of 70 Ω·m. Findings. Within the studied envelope of parameters neither the resistivity of the soil nor the thickness of the concrete wall measurably alters the magnetic flux density either at the control point or inside any of the analyzed layers. The configuration of the field is governed almost exclusively by the magnitude of the phase current and by the geometry of the conductor cluster. At the reference point the peak flux density is approximately 1.5 μT and is reached at phase angles of about 115° and 295°; the value rises to roughly 2.27 μT at the ground surface, to about 8 μT on the upper outer face of the tunnel and exceeds 10 μT on its inner face, while pronounced local maxima are observed in the immediate vicinity of the individual phase wires. Originality. A systematic quantitative demonstration is provided that for a 110 kV underground concrete collector in typical urban operating conditions the soil and the reinforced-concrete envelope contribute negligibly to magnetic-field attenuation at 50 Hz. The widespread informal design assumption about the natural shielding role of these media is therefore not supported within the considered ranges of parameters. Practical value. The reported results allow designers to omit detailed soil and concrete characterization from preliminary magnetic-field calculations above underground collectors and to instead direct mitigation efforts toward optimization of phase-conductor geometry or toward dedicated active and passive shielding solutions, the only practically effective routes to a noticeable reduction of magnetic flux density in compact underground transmission infrastructure.

  • MATHEMATICAL MODELING OF A LAYERED ORTHOGONAL EDDY CURRENT CONVERTER

    by Yurii Khomiak, Tetiana Drozdova, Ivan Korniev, Mykyta Noskov

    The article presents the results of a theoretical study of the interaction between an eddy current probe (ECP) and a ferromagnetic specimen containing a surface crack. The relevance of the study stems from the need to improve the reliability and selectivity of eddy current nondestructive testing of metallic components, particularly in cases where conventional ECPs exhibit low resistance to variations in lift-off distance, magnetic permeability, and electrical conductivity of the test object. To address these limitations, the authors have developed an orthogonal eddy current probe that provides spatial separation of the excitation and signal detection functions. A mathematical model of the ECP–crack interaction is proposed, taking into account the surface nature of eddy currents and their orientation along the defect. In the model, the probe coils are represented as idealized conductors, enabling an analytical description of the influence of geometric parameters of both the ECP and the specimen on the output signal. The obtained analytical relationships describe the dependence of the signal amplitude on the probe’s angular position, crack size, lift-off distance between the ECP and the specimen surface, as well as on the ratio of the excitation and sensing coil dimensions.


  • MAGNETOMETER BASED ON A PARAMETRIC INDUCTIVE SENSOR IN A RESONANT CIRCUIT

    by Yurii Khomiak, Ivan Kornіev

    This paper presents the development and experimental investigation of a magnetometer based on a parametric magnetic inductance sensor integrated into a self-oscillating LC circuit. The sensing element is a single-layer coil with a soft ferromagnetic core, whose inductance varies in response to an external magnetic field. This inductance modulation results in a shift in the oscillator frequency, enabling magnetic field measurements by tracking frequency changes. The proposed sensor architecture is compact, energy-efficient, and exhibits stable, repeatable, and monotonic response characteristics over a wide range of magnetic fields. Experimental testing using a calibrated solenoid confirms the device’s high sensitivity and minimal hysteresis. The proposed solution offers a cost-effective and digitally compatible alternative to conventional fluxgate magnetometer designs, with potential applications in industrial instrumentation, field diagnostics, and electromagnetic measurements

  • Open Access

    APPLICATION OF A PERSONAL COMPUTER FOR CONDUCTING AND PROCESSING THE EDDY CURRENT CONTROL SIGNAL

    by Ivan Korniev, Yuri Homyak, Marharyta Pozniakova

    Methods of formation and processing of eddy current converter signals using a personal computer are considered. Eddy current transducers play a crucial role in contactless measurements and find applications in various industries, including industrial, aviation, and medical fields. The article delves into the fundamental aspects of eddy current transducers, including their technical specifications and operating principles. It also examines the equipment and software necessary for signal acquisition and processing, offering guidance on selecting the appropriate tools and programs. signal generation methods for eddy current transducers and the key parameters affecting measurement accuracy are discussed. Additionally, it provides an overview of signal processing methods, including harmonic analysis, filtering, and determining object parameters for measurement. Furthermore, it explores practical applications of eddy current transducers and provides examples of projects where this technology has been applied. The provided information enables a clear understanding of how to use an eddy current converter with a personal computer for signal collection and processing, making the publication useful for engineers, scientists, and specialists in the field of measurements and non-destructive testing.