Rachel Megan Meister
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rachel Megan Meister has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Luca Ravotto
Institute of Pharmacology and Toxicology and Neuroscience Center Zurich, University and ETH Zurich, Winterthurerstr. 190, 8057, Zurich, Switzerland
6 shared publications - Bruno Weber
Institute of Pharmacology and Toxicology, University of Zurich, Zurich, Switzerland
5 shared publications - Aiman S. Saab
Institute of Pharmacology and Toxicology, University of Zurich, Zurich, Switzerland
4 shared publications - Felipe Velasquez Moros
Institute of Pharmacology and Toxicology, University of Zurich, Zurich, Switzerland
4 shared publications - Dorian Amiet
OST – Eastern Switzerland University of Applied Sciences, IMES Institute for Microelectronics, Embedded Systems and Sensorics, Rapperswil, Switzerland
3 shared publications - Paul Zbinden
OST – Eastern Switzerland University of Applied Sciences, IMES Institute for Microelectronics, Embedded Systems and Sensorics, Rapperswil, Switzerland
3 shared publications
Latest Publications
- Open Access
- 9 October 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (41)
Rod photoreceptors have a dual dependency on both aerobic glycolysis and OXPHOS and diverge metabolically from other retinal neurons
The retina metabolizes glucose into lactate, a hallmark of aerobic glycolysis known as the Warburg effect. Although evidence points to rod photoreceptors as the primary source of aerobic glycolysis, a comparison of the energy metabolism in different retinal neurons has yet to be performed. We combined two-photon fluorescence lifetime imaging of biosensors with pharmacological protocols to analyze metabolic dynamics in healthy and diseased rod photoreceptors and RBPMS-positive ganglion and calretinin-positive amacrine cells. Our data reveal distinct metabolic profiles among retinal neurons, identify rods as the drivers of aerobic glycolysis, demonstrate that inner retinal neurons rely on oxidative phosphorylation, show that rods need both glycolysis and oxidative phosphorylation to maintain ATP levels, and suggest that rods can metabolize lactate. A mutation causing retinitis pigmentosa increases lactate production in rods but changes the energy metabolism only subtly otherwise. Our results improve the understanding of retinal physiology and are relevant for pathologies involving imbalanced energy metabolism.
- 9 October 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (41)
Open AccessRod photoreceptors have a dual dependency on both aerobic glycolysis and OXPHOS and diverge metabolically from other retinal neurons
The retina metabolizes glucose into lactate, a hallmark of aerobic glycolysis known as the Warburg effect. Although evidence points to rod photoreceptors as the primary source of aerobic glycolysis, a comparison of the energy metabolism in different retinal neurons has yet to be performed. We combined two-photon fluorescence lifetime imaging of biosensors with pharmacological protocols to analyze metabolic dynamics in healthy and diseased rod photoreceptors and RBPMS-positive ganglion and calretinin-positive amacrine cells. Our data reveal distinct metabolic profiles among retinal neurons, identify rods as the drivers of aerobic glycolysis, demonstrate that inner retinal neurons rely on oxidative phosphorylation, show that rods need both glycolysis and oxidative phosphorylation to maintain ATP levels, and suggest that rods can metabolize lactate. A mutation causing retinitis pigmentosa increases lactate production in rods but changes the energy metabolism only subtly otherwise. Our results improve the understanding of retinal physiology and are relevant for pathologies involving imbalanced energy metabolism.
- Open Access
PURELIGHT: a quantitative photon-counting framework unifying intensity and lifetime imaging at video rate across detector technologies
Quantitative fluorescence microscopy requires photon-efficiency, speed and accurate intensity and lifetime measurements. Time-correlated single-photon counting (TCSPC) simultaneously captures intensity and lifetime, but photon pile-up distorts both signals at high count rates, preventing fast acquisitions. Existing corrections discard photons, distort intensity, or require specialized detectors. Here we introduce PURELIGHT, an integrated hardware and software framework that simultaneously recovers undistorted intensities and lifetimes at count rates far beyond conventional pile-up limits. PURELIGHT works with hybrid photodetectors, silicon photomultipliers and photomultiplier tubes while retaining over three times more photons than alternative approaches. Using two-photon imaging, we showcase PURELIGHT’s superior accuracy and spatial contrast, demonstrating video-rate subcellular lifetime imaging in awake mice, a unique lifetime-calibrated ratiometric modality and crosstalk-free temporal multiplexing. By removing the limits that have confined TCSPC to low-signal applications, PURELIGHT promotes the adoption of quantitative, photon-efficient microscopy across the life sciences.
Open AccessPURELIGHT: a quantitative photon-counting framework unifying intensity and lifetime imaging at video rate across detector technologies
Quantitative fluorescence microscopy requires photon-efficiency, speed and accurate intensity and lifetime measurements. Time-correlated single-photon counting (TCSPC) simultaneously captures intensity and lifetime, but photon pile-up distorts both signals at high count rates, preventing fast acquisitions. Existing corrections discard photons, distort intensity, or require specialized detectors. Here we introduce PURELIGHT, an integrated hardware and software framework that simultaneously recovers undistorted intensities and lifetimes at count rates far beyond conventional pile-up limits. PURELIGHT works with hybrid photodetectors, silicon photomultipliers and photomultiplier tubes while retaining over three times more photons than alternative approaches. Using two-photon imaging, we showcase PURELIGHT’s superior accuracy and spatial contrast, demonstrating video-rate subcellular lifetime imaging in awake mice, a unique lifetime-calibrated ratiometric modality and crosstalk-free temporal multiplexing. By removing the limits that have confined TCSPC to low-signal applications, PURELIGHT promotes the adoption of quantitative, photon-efficient microscopy across the life sciences.
- Open Access
Photoreceptors have a dual dependency on both aerobic glycolysis and OXPHOS and diverge metabolically from other retinal neurons
The retina metabolizes glucose into lactate, a hallmark of aerobic glycolysis known as the Warburg effect. Although evidence points to rod photoreceptors as the primary source of aerobic glycolysis, a comparison of the energy metabolism in different retinal neurons has yet to be performed. We combined two-photon fluorescence lifetime imaging of biosensors with pharmacological protocols to analyse metabolic dynamics in healthy and diseased photoreceptors and in inner retinal neurons. Our data reveal distinct metabolic profiles among retinal neurons, identify rods as the drivers of aerobic glycolysis, demonstrate that inner retinal neurons rely on oxidative phosphorylation, show that rods need both glycolysis and oxidative phosphorylation to maintain ATP levels, and suggest that rods can metabolize lactate. A mutation causing retinitis pigmentosa increases lactate production in rods but changes the energy metabolism only subtly otherwise. Our results improve the understanding of retinal physiology and are relevant for pathologies involving imbalanced energy metabolism.
Open AccessPhotoreceptors have a dual dependency on both aerobic glycolysis and OXPHOS and diverge metabolically from other retinal neurons
The retina metabolizes glucose into lactate, a hallmark of aerobic glycolysis known as the Warburg effect. Although evidence points to rod photoreceptors as the primary source of aerobic glycolysis, a comparison of the energy metabolism in different retinal neurons has yet to be performed. We combined two-photon fluorescence lifetime imaging of biosensors with pharmacological protocols to analyse metabolic dynamics in healthy and diseased photoreceptors and in inner retinal neurons. Our data reveal distinct metabolic profiles among retinal neurons, identify rods as the drivers of aerobic glycolysis, demonstrate that inner retinal neurons rely on oxidative phosphorylation, show that rods need both glycolysis and oxidative phosphorylation to maintain ATP levels, and suggest that rods can metabolize lactate. A mutation causing retinitis pigmentosa increases lactate production in rods but changes the energy metabolism only subtly otherwise. Our results improve the understanding of retinal physiology and are relevant for pathologies involving imbalanced energy metabolism.
- Open Access
- 19 August 2025
- Published by Springer Nature in Communications Biology
- Vol. 8 (1) , 1-14
Abundance-biased codon diversification prevents recombination in AAV production and ensures robust in vivo expression of functional FRET sensors
The delivery of genetically encoded fluorescent sensors via adeno-associated viral vectors (AAVs) enables the quantification of biological analytes with high spatiotemporal resolution in living animals. In this study, we expose an unreported problem of the approach, in which the presence of repeated subsequences in the sensor’s DNA sequence triggers recombination during AAV production. In the case of Förster Resonance Energy Transfer (FRET) sensors, recombination leads to a mixture of fluorescent products, severely compromising in vivo functionality. To counter this phenomenon, we introduce Abundance-Biased Codon Diversification (ABCD), a modification of a previously reported codon diversification method that prevents recombination without sacrificing codon optimization for a target organism. We demonstrate that ABCD greatly facilitates in vivo studies by restoring the functionality of FRET sensors and advanced inducible expression systems delivered via AAV vectors. Our approach offers a robust solution to a previously overlooked challenge, significantly expanding the range of future applications in quantitative imaging and genetic manipulation in living animals using AAV-mediated strategies.
- 19 August 2025
- Published by Springer Nature in Communications Biology
- Vol. 8 (1) , 1-14
Open AccessAbundance-biased codon diversification prevents recombination in AAV production and ensures robust in vivo expression of functional FRET sensors
The delivery of genetically encoded fluorescent sensors via adeno-associated viral vectors (AAVs) enables the quantification of biological analytes with high spatiotemporal resolution in living animals. In this study, we expose an unreported problem of the approach, in which the presence of repeated subsequences in the sensor’s DNA sequence triggers recombination during AAV production. In the case of Förster Resonance Energy Transfer (FRET) sensors, recombination leads to a mixture of fluorescent products, severely compromising in vivo functionality. To counter this phenomenon, we introduce Abundance-Biased Codon Diversification (ABCD), a modification of a previously reported codon diversification method that prevents recombination without sacrificing codon optimization for a target organism. We demonstrate that ABCD greatly facilitates in vivo studies by restoring the functionality of FRET sensors and advanced inducible expression systems delivered via AAV vectors. Our approach offers a robust solution to a previously overlooked challenge, significantly expanding the range of future applications in quantitative imaging and genetic manipulation in living animals using AAV-mediated strategies.
- Open Access
- 1 April 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (02) , 025009-16
A low-cost FPGA-based approach for pile-up corrected high-speed in vivo FLIM imaging
Two-photon excited fluorescence microscopy (2PM) has revolutionized neuroscience, allowing the investigation of biological dynamics with subcellular and subsecond resolution in living animals.1,2 Fluorescent labeling with proteins and dyes has been used to elucidate the morphology and behavior of cells and blood vessels under physiological and pathological conditions, whereas functional readouts such as calcium imaging or blood flow measurements have shed light on dynamic phenomena such as neuronal activity and neurovascular coupling.3,4 However, despite its successes, intensity-based 2PM is heavily affected by confounding factors such as fluorophore expression, tissue scattering and absorption, and sample motion. Although these problems can be somewhat alleviated using ratiometric approaches, the wavelength dependence of scattering and absorption still prevents accurate quantitation. Thus, traditional 2PM is insufficient to investigate biological processes such as metabolism, which require the precise quantification of molecule concentrations.5,6
- 1 April 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (02) , 025009-16
Open AccessA low-cost FPGA-based approach for pile-up corrected high-speed in vivo FLIM imaging
Two-photon excited fluorescence microscopy (2PM) has revolutionized neuroscience, allowing the investigation of biological dynamics with subcellular and subsecond resolution in living animals.1,2 Fluorescent labeling with proteins and dyes has been used to elucidate the morphology and behavior of cells and blood vessels under physiological and pathological conditions, whereas functional readouts such as calcium imaging or blood flow measurements have shed light on dynamic phenomena such as neuronal activity and neurovascular coupling.3,4 However, despite its successes, intensity-based 2PM is heavily affected by confounding factors such as fluorophore expression, tissue scattering and absorption, and sample motion. Although these problems can be somewhat alleviated using ratiometric approaches, the wavelength dependence of scattering and absorption still prevents accurate quantitation. Thus, traditional 2PM is insufficient to investigate biological processes such as metabolism, which require the precise quantification of molecule concentrations.5,6
- Open Access
A low-cost FPGA-based approach for pile-up corrected high-speed in vivo FLIM imaging
Intensity-based two-photon microscopy (2PM) is a cornerstone of biomedical research but lacks the ability to measure concentrations, a pivotal task for longitudinal studies and quantitative comparisons. Fluorescence Lifetime Imaging (FLIM) based on Time-Correlated Single Photon Counting (TCSPC) can overcome those limits but suffers from “pile-up” distortions at high photon count rates, severely limiting acquisition speed. We introduce the “laser period blind time” (LPBT) method to correct pile-up distortions in photon counting electronics, enabling reliable low-cost TCSPC-FLIM at high count rates. The correction was implemented on low-cost hardware based on a field programable gate array (FPGA) and validated using a combination of in silico simulations and in vitro, ex vivo and in vivo measurements. The LBPT approach achieves <3% error in lifetime measurements at count rates more than ten times higher than traditional limits, allowing robust FLIM imaging of sub-second metabolite dynamics with subcellular resolution. Our work enables high-precision, cost-effective FLIM imaging at rates comparable to commercial systems and at a fraction of the cost, facilitating the adoption of FLIM across all areas of research needing affordable, quantitative live imaging solutions.
Open AccessA low-cost FPGA-based approach for pile-up corrected high-speed in vivo FLIM imaging
Intensity-based two-photon microscopy (2PM) is a cornerstone of biomedical research but lacks the ability to measure concentrations, a pivotal task for longitudinal studies and quantitative comparisons. Fluorescence Lifetime Imaging (FLIM) based on Time-Correlated Single Photon Counting (TCSPC) can overcome those limits but suffers from “pile-up” distortions at high photon count rates, severely limiting acquisition speed. We introduce the “laser period blind time” (LPBT) method to correct pile-up distortions in photon counting electronics, enabling reliable low-cost TCSPC-FLIM at high count rates. The correction was implemented on low-cost hardware based on a field programable gate array (FPGA) and validated using a combination of in silico simulations and in vitro, ex vivo and in vivo measurements. The LBPT approach achieves <3% error in lifetime measurements at count rates more than ten times higher than traditional limits, allowing robust FLIM imaging of sub-second metabolite dynamics with subcellular resolution. Our work enables high-precision, cost-effective FLIM imaging at rates comparable to commercial systems and at a fraction of the cost, facilitating the adoption of FLIM across all areas of research needing affordable, quantitative live imaging solutions.