Endalkachew Degarege Almawu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Endalkachew Degarege Almawu has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Federico Cecati
Department of Industrial Engineering, University of Trento, Trento, Italy
2 shared publications - Marco Liserre
Kiel University
2 shared publications
Latest Publications
- Open Access
Robust Stability Analysis of Grid-Forming Converter-Dominated Grids Using Grey-Box Modelling Approach
In recent years, continuous efforts have been made for the modelling and stability analysis of converter-dominated grids. Ensuring stability in converter-dominated grids presents a unique challenge, primarily due to the manufacturers’ intellectual property (IP) protections. Determining the robust stability boundary of a grid incorporating converters from various manufacturers remains an area requiring extensive research. Recently, a grey-box modelling approach for studying interoperability has been proposed in the literature. However, the existing methodology is solely suitable for grid-following converters. This study bridges the gap by proposing a GFM converters model which aligns with the methodology for analysing the interoperability of GFL converters. The model is designed to represent a range of control system implementations across different manufacturers. Using robust control theory, this approach assesses the grid’s stability margin and sensitivity analysis of the control loops under various conditions considering a single GFM converter. The results are validated both analytically and through real-time hardware-in-the-loop (HIL) tests to demonstrate the model accuracy in predicting robust stability margin and sensitivity of the control loops in GFM converter-dominated grids.
Open AccessRobust Stability Analysis of Grid-Forming Converter-Dominated Grids Using Grey-Box Modelling Approach
In recent years, continuous efforts have been made for the modelling and stability analysis of converter-dominated grids. Ensuring stability in converter-dominated grids presents a unique challenge, primarily due to the manufacturers’ intellectual property (IP) protections. Determining the robust stability boundary of a grid incorporating converters from various manufacturers remains an area requiring extensive research. Recently, a grey-box modelling approach for studying interoperability has been proposed in the literature. However, the existing methodology is solely suitable for grid-following converters. This study bridges the gap by proposing a GFM converters model which aligns with the methodology for analysing the interoperability of GFL converters. The model is designed to represent a range of control system implementations across different manufacturers. Using robust control theory, this approach assesses the grid’s stability margin and sensitivity analysis of the control loops under various conditions considering a single GFM converter. The results are validated both analytically and through real-time hardware-in-the-loop (HIL) tests to demonstrate the model accuracy in predicting robust stability margin and sensitivity of the control loops in GFM converter-dominated grids.
- Open Access
- 25 December 2024
- Published by MDPI AG in Preprints.org
Robust Stability Analysis of Grid-Forming Converters Dominated Grids Using Grey-Box Modeling Approach
In the recent years, a continuous effort have been made for modeling and stability analysis of converter dominated grids. Ensuring stability in converter dominated grid presents a unique challenge, primarily due to manufacturers’ intellectual property (IP) protections. Determining the robust stability boundary of a grid incorporating converters from various manufacturers remains an area requiring extensive research. Recently, a grey-box modeling approach for studying interoperability has been proposed in literature. However, the existing methodology is solely suitable for grid following converters. This study bridges the gap by proposing GFM converters model which aligns with the methodology for analyzing interoperability of GFL converters. The model is designed to represent a range of control system implementations across different manufacturers. Using robust control theory, this approach assesses the grid’s stability margin and sensitivity analysis of the uncertain control loops under various conditions considering a single GFM converter. The results are validated both analytically and through real time hardware-in-the-loop (HIL) test to demonstrate the model’s accuracy in predicting robust stability margin and the sensitive of the control loops in GFM converters dominated grids.
- 25 December 2024
- Published by MDPI AG in Preprints.org
Open AccessRobust Stability Analysis of Grid-Forming Converters Dominated Grids Using Grey-Box Modeling Approach
In the recent years, a continuous effort have been made for modeling and stability analysis of converter dominated grids. Ensuring stability in converter dominated grid presents a unique challenge, primarily due to manufacturers’ intellectual property (IP) protections. Determining the robust stability boundary of a grid incorporating converters from various manufacturers remains an area requiring extensive research. Recently, a grey-box modeling approach for studying interoperability has been proposed in literature. However, the existing methodology is solely suitable for grid following converters. This study bridges the gap by proposing GFM converters model which aligns with the methodology for analyzing interoperability of GFL converters. The model is designed to represent a range of control system implementations across different manufacturers. Using robust control theory, this approach assesses the grid’s stability margin and sensitivity analysis of the uncertain control loops under various conditions considering a single GFM converter. The results are validated both analytically and through real time hardware-in-the-loop (HIL) test to demonstrate the model’s accuracy in predicting robust stability margin and the sensitive of the control loops in GFM converters dominated grids.