Changyun Quan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Changyun Quan has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Binjie Xu
Kingmed, China
1 shared publication - Haixia Yang
Cofoe Medical Technology Co., Ltd., No. 87, Section 1, Huanbao East Road, Changsha 410000, China
1 shared publication - Liping Wen
Cofoe Medical Technology Co., Ltd., No. 816 Zhenghua Road, Changsha 410021, China
1 shared publication - Minghui Yang
Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha, China
1 shared publication - Xueqin Huang
Cofoe Medical Technology Co., Ltd., No. 87, Section 1, Huanbao East Road, Changsha 410000, China
1 shared publication - Yuanyuan Liu
Hunan Institute for Drug Control, Changsha 410001, China
1 shared publication
Latest Publications
- Open Access
- 27 December 2024
- Published by MDPI AG in Biosensors
- Vol. 15 (1) , 9
Electrochemical Glucose Sensor Based on Dual Redox Mediators
Electrochemical glucose sensor holds significant promise for the monitoring of blood glucose levels in diabetic patients. In this study, we proposed a novel electrochemical glucose sensor based on 1,10-Phenanthroline-5,6-dione (PD)/Ru(III) as a dual redox mediator. The synergistic effect of PD and Ru(III) was utilized to efficiently facilitate the electron transfer between the enzyme-active center and the electrode. Then, a commercial disposable electrochemical glucose sensor was constructed based on screen-printing electrodes. Experimental results indicated the synergy between PD and Ru(III) provided a promising electron transfer environment for a glucose dehydrogenase (GDH)-catalyzed glucose reaction. The sensor exhibits a linear glucose response range from 0.01 to 38.6 mmol/L, with a limit of detection (LOD) as low as 7.0 µmol/L and a sensitivity of 38 µA·L/(mmol·cm2). The accuracy of the sensor was further validated in spiked recovery tests of human venous blood samples. The glucose recovery rate was between 99.5% and 107%, with a relative standard deviation (RSD) of less than 3.2%. These results demonstrate that our sensor has high potential for commercialization and practical application in glucose monitoring.
- 27 December 2024
- Published by MDPI AG in Biosensors
- Vol. 15 (1) , 9
Open AccessElectrochemical Glucose Sensor Based on Dual Redox Mediators
Electrochemical glucose sensor holds significant promise for the monitoring of blood glucose levels in diabetic patients. In this study, we proposed a novel electrochemical glucose sensor based on 1,10-Phenanthroline-5,6-dione (PD)/Ru(III) as a dual redox mediator. The synergistic effect of PD and Ru(III) was utilized to efficiently facilitate the electron transfer between the enzyme-active center and the electrode. Then, a commercial disposable electrochemical glucose sensor was constructed based on screen-printing electrodes. Experimental results indicated the synergy between PD and Ru(III) provided a promising electron transfer environment for a glucose dehydrogenase (GDH)-catalyzed glucose reaction. The sensor exhibits a linear glucose response range from 0.01 to 38.6 mmol/L, with a limit of detection (LOD) as low as 7.0 µmol/L and a sensitivity of 38 µA·L/(mmol·cm2). The accuracy of the sensor was further validated in spiked recovery tests of human venous blood samples. The glucose recovery rate was between 99.5% and 107%, with a relative standard deviation (RSD) of less than 3.2%. These results demonstrate that our sensor has high potential for commercialization and practical application in glucose monitoring.