Zhenyu Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhenyu Gao has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jianhua Shao
School of Civil engineering and architecture, Jiangsu University of science and technology, Zhenjiang 212003, China
2 shared publications - Zhanguang Wang
School of Architectural Engineering, Kaili University, Kaili 556011, China
2 shared publications - Dongmei Li
Department of Civil Engineering, Jiangsu University of Science and Technology, Changhui Road, Dantu District, Zhenjiang 212100, China
1 shared publication - Weihan Yang
School of Civil and Architectural Engineering, Nanchang Institute of Technology, Nanchang 330099, China
1 shared publication - Weihan Yang
School of Civil and Architectural Engineering, Jiangxi University of Water Resources and Electric Power, Nanchang 330099, China
1 shared publication
Latest Publications
- Open Access
Parametric Study on an Integrated Sleeve Mortise-and-Tenon Steel–Timber Composite Beam–Column Joints
To address the limitations of traditional timber mortise-and-tenon joints, particularly their low pull-out resistance and rapid stiffness degradation under cyclic loading, this study proposes a novel integrated sleeve mortise-and-tenon steel–timber composite beam–column joint. Building upon prior experimental validation and numerical model verification, a comprehensive parametric study was conducted to systematically investigate the influence of key geometric parameters on the seismic performance of the joint. The investigated parameters included beam sleeve thickness (1–10 mm), sleeve length (150–350 mm), bolt diameter (4–16 mm), and the dimensions and thickness of stiffeners. The results indicate that a sleeve thickness of 2–3 mm yields the optimal overall performance: sleeves thinner than 2 mm are prone to yielding, while those thicker than 3 mm induce stress concentration in the timber beam. A sleeve length of approximately 250 mm provides the highest initial stiffness and a ductility coefficient exceeding 4.0, representing the best seismic behavior. Bolt diameters within the range of 8–10 mm produce full and stable hysteresis loops, effectively balancing load-carrying capacity and energy dissipation; smaller diameters lead to pinching failure, whereas larger diameters trigger premature plastic deformation in the timber. Furthermore, stiffeners with a width of 40 mm and a thickness of 2 mm effectively enhance joint stiffness, promote a uniform stress distribution, and mitigate local damage. The optimized joint configuration demonstrates excellent ductility, stable hysteretic behavior, and a high load capacity, providing a robust technical foundation for the design and practical application of advanced steel–timber composite connections.
Open AccessParametric Study on an Integrated Sleeve Mortise-and-Tenon Steel–Timber Composite Beam–Column Joints
To address the limitations of traditional timber mortise-and-tenon joints, particularly their low pull-out resistance and rapid stiffness degradation under cyclic loading, this study proposes a novel integrated sleeve mortise-and-tenon steel–timber composite beam–column joint. Building upon prior experimental validation and numerical model verification, a comprehensive parametric study was conducted to systematically investigate the influence of key geometric parameters on the seismic performance of the joint. The investigated parameters included beam sleeve thickness (1–10 mm), sleeve length (150–350 mm), bolt diameter (4–16 mm), and the dimensions and thickness of stiffeners. The results indicate that a sleeve thickness of 2–3 mm yields the optimal overall performance: sleeves thinner than 2 mm are prone to yielding, while those thicker than 3 mm induce stress concentration in the timber beam. A sleeve length of approximately 250 mm provides the highest initial stiffness and a ductility coefficient exceeding 4.0, representing the best seismic behavior. Bolt diameters within the range of 8–10 mm produce full and stable hysteresis loops, effectively balancing load-carrying capacity and energy dissipation; smaller diameters lead to pinching failure, whereas larger diameters trigger premature plastic deformation in the timber. Furthermore, stiffeners with a width of 40 mm and a thickness of 2 mm effectively enhance joint stiffness, promote a uniform stress distribution, and mitigate local damage. The optimized joint configuration demonstrates excellent ductility, stable hysteretic behavior, and a high load capacity, providing a robust technical foundation for the design and practical application of advanced steel–timber composite connections.
- Open Access
Experimental and Numerical Simulation Study on the Mechanical Properties of Integrated Sleeve Mortise and Tenon Steel–Wood Composite Joints
In view of the application status and technical challenges of steel–wood composite joints in architecture, this paper proposes an innovative connection technology to solve issues such as susceptibility to pry-out at beam–column joints and low load-bearing capacity and to provide various reinforcement methods in order to meet the different structural requirements and economic benefits. By designing and manufacturing four groups of beam–column joint specimens with different reinforcement methods, including no reinforcement, structural adhesive and angle steel reinforcement, 4 mm thick steel sleeve reinforcement, and 6 mm thick steel sleeve reinforcement, monotonic loading tests and finite element simulations were carried out, respectively. This research found that unreinforced specimens and structural adhesive angle steel-reinforced joints exhibited obvious mortise and tenon compression deformation and, moreover, tenon pulling phenomena at load values of approximately 2 kN and 2.6 kN, respectively. However, the joint reinforced by a steel sleeve showed a significant improvement in the tenon pulling phenomenon and demonstrated excellent initial stiffness characteristics. The failure mode of the steel sleeve-reinforced joints is primarily characterized by the propagation of cracks at the edges of the steel plate and the tearing of the wood, but the overall structure remains intact. The initial rotational stiffness of the joints reinforced with angle steel and self-tapping screws, the joints reinforced with 4 mm thick steel sleeves, and the joints reinforced with 6 mm thick steel sleeves are 3.96, 6.99, and 13.62 times that of the pure wooden joints, while the ultimate bending moments are 1.97, 7.11, and 7.39 times, respectively. Using finite element software to simulate four groups of joints to observe their stress changes, the areas with high stress in the joints without sleeve reinforcement are mainly located at the upper and lower ends of the tenon, where the compressive stress at the upper edge of the tenon and the tensile stress at the lower flange are both distributed along the grain direction of the beam. The stress on the column sleeve of the joints reinforced with steel sleeves and bolts is relatively low, while the areas with high strain in the beam sleeve are mainly concentrated on the side with the welded stiffeners and its surroundings; the strain around the bolt holes is also quite noticeable.
Open AccessExperimental and Numerical Simulation Study on the Mechanical Properties of Integrated Sleeve Mortise and Tenon Steel–Wood Composite Joints
In view of the application status and technical challenges of steel–wood composite joints in architecture, this paper proposes an innovative connection technology to solve issues such as susceptibility to pry-out at beam–column joints and low load-bearing capacity and to provide various reinforcement methods in order to meet the different structural requirements and economic benefits. By designing and manufacturing four groups of beam–column joint specimens with different reinforcement methods, including no reinforcement, structural adhesive and angle steel reinforcement, 4 mm thick steel sleeve reinforcement, and 6 mm thick steel sleeve reinforcement, monotonic loading tests and finite element simulations were carried out, respectively. This research found that unreinforced specimens and structural adhesive angle steel-reinforced joints exhibited obvious mortise and tenon compression deformation and, moreover, tenon pulling phenomena at load values of approximately 2 kN and 2.6 kN, respectively. However, the joint reinforced by a steel sleeve showed a significant improvement in the tenon pulling phenomenon and demonstrated excellent initial stiffness characteristics. The failure mode of the steel sleeve-reinforced joints is primarily characterized by the propagation of cracks at the edges of the steel plate and the tearing of the wood, but the overall structure remains intact. The initial rotational stiffness of the joints reinforced with angle steel and self-tapping screws, the joints reinforced with 4 mm thick steel sleeves, and the joints reinforced with 6 mm thick steel sleeves are 3.96, 6.99, and 13.62 times that of the pure wooden joints, while the ultimate bending moments are 1.97, 7.11, and 7.39 times, respectively. Using finite element software to simulate four groups of joints to observe their stress changes, the areas with high stress in the joints without sleeve reinforcement are mainly located at the upper and lower ends of the tenon, where the compressive stress at the upper edge of the tenon and the tensile stress at the lower flange are both distributed along the grain direction of the beam. The stress on the column sleeve of the joints reinforced with steel sleeves and bolts is relatively low, while the areas with high strain in the beam sleeve are mainly concentrated on the side with the welded stiffeners and its surroundings; the strain around the bolt holes is also quite noticeable.