Aya Mohamed Adly
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aya Mohamed Adly has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Amira Farid El-Zoghbi
Professor of Conservative Dentistry, Faculty of Dentistry, Cairo University, Giza, Egypt
1 shared publication- Dina Kamal
Conservative Dentistry Department, Faculty of Dentistry, Cairo University, Cairo, Egypt
1 shared publication - Olfat Elsayed Hassanein
Conservative Dentistry Department, Faculty of Dentistry, Cairo University, Cairo, Egypt
1 shared publication - Shereen Hafez Ibrahim
Department of Conservative Dentistry, Faculty of Dentistry, Cairo University, Cairo, Egypt
1 shared publication - Yomna Sayed Khallaf
Conservative Dentistry Department, Faculty of Dentistry, Cairo University, Cairo, Egypt
1 shared publication
Latest Publications
- Open Access
- 3 September 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1) , 1662
Clinical performance of a giomer-based pit and fissure sealant with and without air-abrasion pretreatment: a 12-month randomized clinical trial
Background: Pit and fissure sealants are widely used for caries prevention; however, their long-term success depends largely on retention. Giomer-based sealants containing surface pre-reacted glass ionomer fillers offer bioactive properties, yet concerns remain regarding their bonding durability when applied with mild self-etch primers. This randomized clinical trial evaluated the effect of bioactive glass air-abrasion pretreatment on the retention and caries preventive efficacy of a giomer-based sealant in young adults over 12 months. Methods: This parallel-arm randomized clinical trial included 96 participants, each contributing one eligible sound permanent molar ( n = 48 per group). Participants were randomly allocated to either bioactive glass air-abrasion pretreatment followed by application of a giomer-based sealant (intervention group) or application of the same sealant without pretreatment (comparator group). Sealant retention and secondary caries incidence were evaluated at baseline, 6 months, and 12 months using Simonsen’s criteria, and modified United States Public Health Service (USPHS) criteria, respectively. The primary outcome was sealant retention at 12 months, whereas secondary caries incidence was assessed as a secondary outcome. Intergroup comparisons were analyzed using the Chi-square test. Intragroup comparisons were analyzed using Cochran’s Q test followed by multiple comparisons. Relative risk with 95% confidence intervals was calculated. Statistical significance was set at p ≤ 0.05. Results: At 6 months, complete sealant retention was observed in 91.7% of teeth in the intervention group and 75.0% in the comparator group, with no statistically significant difference between groups ( p = 0.068). At 12 months, complete sealant retention was significantly higher in the intervention group (87.5%) than in the comparator group (33.3%) ( p < 0.0001). Teeth in the intervention group exhibited an 81.25% lower risk of sealant retention failure compared with the comparator group (RR = 0.1875; 95% CI: 0.0864–0.4069; p < 0.0001). No differences in secondary caries incidence were detected between groups during the 12-month follow-up period ( p = 1.0000). Conclusions: Bioactive glass air-abrasion pretreatment significantly improved the retention of a giomer-based fissure sealant compared with sealant application without pretreatment. No differences in secondary caries incidence were detected between groups during the 12-month follow-up period. Incorporating mechanical surface conditioning prior to sealant placement may enhance sealant retention without compromising preventive efficacy. Trial Registration: https://clinicaltrials.gov/ , (NCT06003452), 15-08-2023.
- 3 September 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1) , 1662
Open AccessClinical performance of a giomer-based pit and fissure sealant with and without air-abrasion pretreatment: a 12-month randomized clinical trial
Background: Pit and fissure sealants are widely used for caries prevention; however, their long-term success depends largely on retention. Giomer-based sealants containing surface pre-reacted glass ionomer fillers offer bioactive properties, yet concerns remain regarding their bonding durability when applied with mild self-etch primers. This randomized clinical trial evaluated the effect of bioactive glass air-abrasion pretreatment on the retention and caries preventive efficacy of a giomer-based sealant in young adults over 12 months. Methods: This parallel-arm randomized clinical trial included 96 participants, each contributing one eligible sound permanent molar ( n = 48 per group). Participants were randomly allocated to either bioactive glass air-abrasion pretreatment followed by application of a giomer-based sealant (intervention group) or application of the same sealant without pretreatment (comparator group). Sealant retention and secondary caries incidence were evaluated at baseline, 6 months, and 12 months using Simonsen’s criteria, and modified United States Public Health Service (USPHS) criteria, respectively. The primary outcome was sealant retention at 12 months, whereas secondary caries incidence was assessed as a secondary outcome. Intergroup comparisons were analyzed using the Chi-square test. Intragroup comparisons were analyzed using Cochran’s Q test followed by multiple comparisons. Relative risk with 95% confidence intervals was calculated. Statistical significance was set at p ≤ 0.05. Results: At 6 months, complete sealant retention was observed in 91.7% of teeth in the intervention group and 75.0% in the comparator group, with no statistically significant difference between groups ( p = 0.068). At 12 months, complete sealant retention was significantly higher in the intervention group (87.5%) than in the comparator group (33.3%) ( p < 0.0001). Teeth in the intervention group exhibited an 81.25% lower risk of sealant retention failure compared with the comparator group (RR = 0.1875; 95% CI: 0.0864–0.4069; p < 0.0001). No differences in secondary caries incidence were detected between groups during the 12-month follow-up period ( p = 1.0000). Conclusions: Bioactive glass air-abrasion pretreatment significantly improved the retention of a giomer-based fissure sealant compared with sealant application without pretreatment. No differences in secondary caries incidence were detected between groups during the 12-month follow-up period. Incorporating mechanical surface conditioning prior to sealant placement may enhance sealant retention without compromising preventive efficacy. Trial Registration: https://clinicaltrials.gov/ , (NCT06003452), 15-08-2023.
- Open Access
- 6 January 2025
- Published by Springer Nature in BDJ Open
- Vol. 11 (1) , 1-11
Clinical validity of fluorescence-based devices versus visual-tactile method in detection of secondary caries around resin composite restorations: diagnostic accuracy study
Objectives: To assess the validity of light-induced and laser-induced fluorescence devices compared to the visual-tactile method for detecting secondary caries around resin composite restorations. Materials and Methods: The study included 20 participants with 30 resin-composite restored teeth. Restorations’ margins were examined using three diagnostic methods: the visual-tactile method (FDI criteria), the light-induced fluorescence camera (VistaCam iX), and the laser-induced fluorescence device (DIAGNOdent pen), and the reference was visual inspection after removal of defective restorations. The validity of each method was evaluated. Inter-examiner reliability was calculated using Cohen’s kappa statistics. The level of significance was set at P = 0.05. Results: DIAGNOdent pen showed the highest sensitivity (100%) followed by VistaCam (98.82%) and the visual-tactile method (98.82%) at the enamel threshold. DIAGNOdent pen and VistaCam had lower specificity values than the visual-tactile method (81.69%, 76.06%, and 88.73% respectively). At the dentin threshold, DIAGNOdent pen yielded the highest sensitivity (89.36%), whereas VistaCam had the lowest (8.51%). The sensitivity of the visual-tactile method was low (57.45%) whereas all diagnostic methods had high specificity. There was perfect agreement in inter-examiner reliability for all assessment methods (Kappa 0.858–0.992). Conclusions: Both fluorescence-based devices and the visual-tactile method are reliable for detecting secondary caries around resin composite restorations. DIAGNOdent pen is accurate in enamel and dentin, while VistaCam and the visual-tactile method can detect secondary caries in enamel only. Clinical Relevance: Fluorescence-based devices could be used as a valuable aid to supplement or as a second opinion after the visual-tactile method. Trial registration: The study was listed on www.clinicaltrials.gov with registration number (NCT04426604) on 11/06/2020.
- 6 January 2025
- Published by Springer Nature in BDJ Open
- Vol. 11 (1) , 1-11
Open AccessClinical validity of fluorescence-based devices versus visual-tactile method in detection of secondary caries around resin composite restorations: diagnostic accuracy study
Objectives: To assess the validity of light-induced and laser-induced fluorescence devices compared to the visual-tactile method for detecting secondary caries around resin composite restorations. Materials and Methods: The study included 20 participants with 30 resin-composite restored teeth. Restorations’ margins were examined using three diagnostic methods: the visual-tactile method (FDI criteria), the light-induced fluorescence camera (VistaCam iX), and the laser-induced fluorescence device (DIAGNOdent pen), and the reference was visual inspection after removal of defective restorations. The validity of each method was evaluated. Inter-examiner reliability was calculated using Cohen’s kappa statistics. The level of significance was set at P = 0.05. Results: DIAGNOdent pen showed the highest sensitivity (100%) followed by VistaCam (98.82%) and the visual-tactile method (98.82%) at the enamel threshold. DIAGNOdent pen and VistaCam had lower specificity values than the visual-tactile method (81.69%, 76.06%, and 88.73% respectively). At the dentin threshold, DIAGNOdent pen yielded the highest sensitivity (89.36%), whereas VistaCam had the lowest (8.51%). The sensitivity of the visual-tactile method was low (57.45%) whereas all diagnostic methods had high specificity. There was perfect agreement in inter-examiner reliability for all assessment methods (Kappa 0.858–0.992). Conclusions: Both fluorescence-based devices and the visual-tactile method are reliable for detecting secondary caries around resin composite restorations. DIAGNOdent pen is accurate in enamel and dentin, while VistaCam and the visual-tactile method can detect secondary caries in enamel only. Clinical Relevance: Fluorescence-based devices could be used as a valuable aid to supplement or as a second opinion after the visual-tactile method. Trial registration: The study was listed on www.clinicaltrials.gov with registration number (NCT04426604) on 11/06/2020.